HHD II
124
4.6.7
Aiming System
This parameter is valid for laser readers and provides a
programmable timeout for the aiming system. If enabled, the scan
line emitted from the reading window is preceded by a red spot
which must illuminate the code center to get the best reading
performance (see figure,
c
). Once the defined timeout is
reached, the red spot disappears and is followed by the scan line
to start the code scanning.
4.7 DECODING PARAMETERS
CAUTION
These parameters are intended to enhance the decoding capability of
the reader for particular applications. Used incorrectly, they can
degrade the reading performance or increase the possibility of a
decoding error.
4.7.1
Ink-Spread
The ink-spread parameter allows the decoding of codes which are not perfectly
printed because the page texture tends to absorb the ink.
4.7.2
Overflow Control
The overflow control parameter can be disabled when decoding codes printed on
small surfaces, which don’t allow the use of an overflow space.
This command does not effect code families 2/5, Code 128 and Code 93.
4.7.3
Interdigit Control
The interdigit control parameter verifies the interdigit spacing for code families Code
39 and Codabar.