Enter/Exit Programming Mode
Standard 2 of 5
158
Gryphon™ I GD44XX
/
GBT4400/GM440X
STANDARD 2 OF 5
The following options apply to the Standard 2 of 5 symbology.
Standard 2 of 5 Enable/Disable
When disabled, the reader will not read Standard 2 of 5 bar codes.
Standard 2 of 5 Check Character Calculation
This option enables/disables calculation and verification of an optional Standard 2 of 5 check
character.
Standard 2 of 5 = Disable
Standard 2 of 5 = Enable
DEFAULT
$C2SEN00(CR)
$C2SEN01(CR)
Standard 2 of 5 Check Character Calculation = Disable
Standard 2 of 5 Check Character Calculation = Enable
DEFAULT
$CS2CC00(CR)
$CS2CC01(CR)