background image

Datalogic ADC, Inc.

959 Terry Street 

|

 Eugene 

|

OR 97402 

USA

Telephone: (1) 541-683-5700 

|

 Fax: (1) 541-345-7140

820055814 (Rev 

D) 

August 2

014

www.datalogic.com

©2010-2014 Datalogic ADC, Inc. • All rights reserved. 
Datalogic and the Datalogic logo are registered trademarks of
Datalogic S.p.A. in many countries, including the U.S.A. and the E.U.

Содержание Gryphon L GD4300

Страница 1: ...Gryphon L GD4300 General Purpose Corded Handheld Laser Bar Code Reader Quick Reference Guide...

Страница 2: ...representative Electronic versions may either be downloadable from the Datalogic website www datalogic com or provided on appropriate media If you visit our website and would like to make comments or...

Страница 3: ...m and Scan 7 Parts of the Reader 8 Scanning Modes 8 Programming Barcodes 11 Resetting the Standard Product Defaults 11 RS 232 Interface 12 IBM Interface 12 USB Interface 13 Keyboard Wedge Interface 14...

Страница 4: ...NOTES...

Страница 5: ...proprietary or confiden tial and c any information that End User under the circumstances should recognize as confidential Proprietary Information does not include any information that the receiving p...

Страница 6: ...User acquires no right or interest in any Proprietary Information 5 2 End User shall not disclose provide or otherwise make available the Propri etary Information of Datalogic or its third party licen...

Страница 7: ...G STATES DATALOGIC S COMPLETE AND ENTIRE OBLIGATION CONCERNING CLAIMS OF PATENT COPYRIGHT OR OTHER INTELLECTUAL PROPERTY INFRINGEMENT CANCELS AND SUPERCEDES ANY PRIOR AGREE MENTS WHETHER ORAL OR WRITT...

Страница 8: ...hts of the parties hereun der shall be governed by and construed in accordance with the laws of the State of Oregon U S A without regard to the rules governing conflicts of law The state or federal co...

Страница 9: ...ight weight and compact size make it perfect for use in retail and office applications Light in dustrial users will appreciate the scanners toughness Its rub ber like overmold cushions the scanner whe...

Страница 10: ...Connect Disconnect Cable 6 Gryphon L GD4300 Connect Disconnect Cable Connect Host Interface Keyboard Wedge Interface RS 232 Interface 1 2...

Страница 11: ...Aim and Scan Quick Reference Guide 7 USB Interface Aim and Scan The area shown in green below illustrates the area of typical max imum performance for the scanner 3 012345 012345...

Страница 12: ...lapsed Trigger Hold Multiple When the trigger is pulled scanning starts and the product scans until the trigger is released or a pro grammable duration1 has elapsed Reading a label does not disable sc...

Страница 13: ...barcode Scan ning is alternatively turned on and off Scan Mode Trigger Single Scan Mode Trigger Hold Multiple Scan Mode Trigger Pulse Multiple Scan Mode Flashing 1 Controlled by Flash On Time and Flas...

Страница 14: ...Scanning Modes 10 Gryphon L GD4300 Scanning Modes continued Scan Mode Always On Scan Mode Stand Mode...

Страница 15: ...on the back cov er of this manual Resetting the Standard Product Defaults If you aren t sure what programming options are in your reader or you ve changed some options and want the factory settings re...

Страница 16: ...232 Interface To use an RS 232 interface scan the barcode for the desired RS 232 host type Select RS 232 Standard Select RS 232 Wincor Nixdorf Select RS 232 OPOS for use with OPOS UPOS JavaPOS IBM Int...

Страница 17: ...face the reader auto detects the USB ca ble and defaults to either the USB keyboard interface GD4330 or USB OEM interface GD4310 Select USB Keyboard with standard key encoding Select USB COM STD1 simu...

Страница 18: ...type Select KBD AT AT PS 2 25 286 30 286 50 50Z 60 70 80 90 95 w Standard Key Encoding Select KBD AT NK IBM AT PS2 with standard key encoding but without external keyboard Select KBD AT ALT AT PS 2 25...

Страница 19: ...KBD XT PC XT w Standard Key Encoding Select KBD IBM 3153 for IBM Terminal 3153 Select KBD IBM M for IBM Terminals 31xx 32xx 34xx 37xx make only keyboard Select KBD IBM MB for IBM Terminals 31xx 32xx...

Страница 20: ...end Standby typical 30mA 5V except 90mA 5V in IBM 46xx Performance Characteristics Light Source 650nm Class 2 Laser Pitch Yaw 50 Skew 65 Roll Tilt 35 Scan Angle 47 normal or 35 narrow Depth of Field T...

Страница 21: ...als VT2x VT3xx VT4xx and Apple and Wand Emulation User Environment Operative Temperature 32 to 122 F 0 to 50 C Storage Temperature 4 to 158 F 20 to 70 C Humidity Operating 5 to 90 relative humidity no...

Страница 22: ...ference the PRG for a more detailed list Indication LED Beeper Power up LED flashes blinks on power up however this may be too rapid to view With a USB interface the LED blinks until enumeration with...

Страница 23: ...e reader is pro grammed to read the type ofbarcodescanned Referto theProductReferenceGuide PRG for more information Barcode label is unread able Check the label to ensure it is not defaced Try scannin...

Страница 24: ...for GD4310 or rated 5 2V minimum 600mA for GD4330 which supplies power directly to the reader via the power connector of the cable Use only authorized power supplies supplied by your Datalogic re sel...

Страница 25: ...ght The laser scanner utilizes a low power laser diode Although staring directly at the laser beam momentarily causes no known biological dam age avoid staring at the beam as one would any very strong...

Страница 26: ...na RoHS Lead Pb Mercury Hg Cadmium Cd Hexavalent Chromium Cr VI Polybrominated biphenyls PBB Polybrominated diphenyl ethers PBDE PART Printed Circuit Board Assembly X O O O O O Assy Optics Block X O O...

Страница 27: ...or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Re orient or rel...

Страница 28: ...duct for actual details as they may vary from those depicted Aiming System The Gryphon aiming system meets the Class 2 requirements for laser safety The laser information is located on the window of t...

Страница 29: ...ww datalogic com German Informationen zur Entsorgung von Elektro und Elektronik Altger ten WEEE erhalten Sie auf der Webseite www datalogic com Spanish Si desea informaci n acerca de los procedimiento...

Страница 30: ...use new or reconditioned parts components subassem blies or products that have been tested as meeting applicable specifications for equivalent new material and products Customer will allow Datalogic t...

Страница 31: ...to i any product which has been damaged modified altered repaired or upgraded by other than Datalogic service person nel or its authorized representatives ii any claimed defect failure or damage which...

Страница 32: ...OM DELAYS IN THE REPLACEMENT OR REPAIR OF PRODUCTS UNDER THE ABOVE THE REMEDY SET FORTH IN THIS WARRANTY STATEMENT IS THE CUS TOMER S SOLE AND EXCLUSIVE REMEDY FOR WARRANTY CLAIMS UNDER NO CIRCUMSTANC...

Страница 33: ...ce during scanning Use a soft dry cloth to clean the product If the product is very soiled clean it with a soft cloth moistened with a diluted non ag gressive cleaning solution or diluted ethyl alcoho...

Страница 34: ...correct heights Reduce or eliminate vibration Reduce or eliminate direct pressure Provide adjustable workstations Provide adequate clearance Provide a suitable working environment Improve work proced...

Страница 35: ...s ber die Ann herung der Gesetze der Mitgliedsstaaten in bezug auf elektromagnetische Vertr glichkeit und Produktsicherheit entsprechen Basado en la aproximaci n de las leyes de los Pa ses Miembros re...

Страница 36: ...one 1 541 683 5700 Fax 1 541 345 7140 820055814 Rev D August 2 014 www datalogic com 2010 2014 Datalogic ADC Inc All rights reserved Datalogic and the Datalogic logo are registered trademarks of Datal...