Technical Specifications
Quick Reference Guide
33
b. Typical input current measured under factory default configuration.
Item
Description
Depth of Field (Typi-
cal)
a
3 mil – 2.9” to 4.7” (7.5cm to 12cm)
13 mil
d
– 1.2” to 23.6” (3cm to 60cm)
20 mil – 1.2” to 31.5” (3cm to 80cm)
Minimum Element
Width
3 mil
Print Contrast Mini-
mum
15% minimum reflectance
Decode Capability
UPC/EAN/JAN, P2 /P5 add-ons; Code 39;
Italian Pharmacode 39; Code 128; C128 ISBT;
Code 128 add-ons; I 2 of 5; Standard 2 of 5;
Code 11;Codabar; EAN 128; Code 93; MSI; GS1
DataBar™ Omnidirectional, GS1 DataBar™
Limited, GS1 DataBar™ Expanded; Code4,
Code5.
Interfaces Sup-
ported
b
RS-232 Std, RS-232 Wincor-Nixdorf, RS-232
OPOS, IBM 46xx (ports5B and 9B), USB Com
Std., USB Keyboard, USB Alternate Keyboard,
USB OEM, Keyboard Wedge (AT with or w/o
Alternate Key, IBM AT PS2 with or w/o Alter-
nate Key, PC-XT, IBM 3153, IBM Terminals
31xx, 32xx,34xx, 37xx make only and make
break keyboard, Digital Terminals VT2x,
VT3xx, VT4xx, and Apple) and Wand Emula-
tion.
User Environment
Operating Tempera-
ture
32° to 122° F (0° to 50° C)
Charging Tempera-
ture
32° to 104° F (0° to 40° C)
Storage Temperature -4° to 158° F (-20° to 70° C)
Humidity
Operating: 5% to 90% relative humidity,
non-condensing
Drop Specifications
Scanner withstands 18 drops from 1.8
meters
(5.9 feet) to concrete