Operating Modes
28
GRYPHON™ I GBT/GM4200
OPERATING MODES
Scan Mode
The reader can be set to operate in one of several scan-
ning modes. See the PRG for more information and set-
tings for any of the following options:
Trigger Single (Default)
This mode is associated with the
typical handheld reader operation. When the trigger is
pulled, illumination is turned on and the scanner attempts
to read a label.
Scanning is activated until one of the following occurs:
•
the programmable “maximum scan on time”
1
has
elapsed
•
a label has been read
•
the trigger is released
Trigger Pulse Multiple -
Scanning begins when the trigger
is pulled and continues after the trigger is released, until
the trigger is pulled again or until the programmable
“maximum scan on time”
1
has elapsed. Reading a label
does not disable scanning. Double Read Timeout
1
pre-
vents undesired multiple reads while in this mode.
Trigger Hold Multiple -
When the trigger is pulled, scan-
ning starts and the product scans until the trigger is
released or “maximum scan on time”
1
has elapsed. Read-
ing a label does not disable scanning. Double Read Time-
out
1
prevents undesired multiple reads while in this
mode.
Always On -
The illuminator is always ON and the reader
is always ready for code reading. Double Read Timeout
1
prevents undesired multiple reads.
Flashing -
The reader illuminator flashes on and off
regardless of the trigger status. Code reading takes place
only during the Flash On Time
2
. Double Read Timeout
1
prevents undesired multiple reads.
Object Detection -
The scanner looks for changes within
its field-of-view. The Aiming Pattern is always on to show
the optimum reading area. If a predefined amount of
movement is detected, the red illumination switches on.
Scanning continues until a label is read or "maximum scan
on time"
1
is reached.
1.
See the Product Reference Guide (PRG) for these and other pro-