![Datalogic DX8200 Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/datalogic/dx8200/dx8200_reference-manual_511921020.webp)
DX8200 CONTROLLER
8
2
2.3.2 Ethernet
RJ45 Modular Connector
DX8200 Controller
5
HUB / SWITCH
3
4
2
1
6
5
3
4
2
1
6
7
8
7
8
RX+
TX-
TX+
RX-
n. c.
n. c.
n. c.
n. c.
n. c. = not connected
RJ45 Modular Connector
2.3.3 Host
Interface
14
1
25
13
25-pin male D-sub Connector
Host Interface Connector Pinout
Pin Name
Function
1
Shield
Internally connected by capacitor to chassis
20
RXAUX
Receive data of auxiliary RS232 (referred to GND)
21
TXAUX
Transmit data of auxiliary RS232 (referred to GND)
8
OUT 1+
Configurable digital output 1 – positive pin
22
OUT 1-
Configurable digital output 1 – negative pin
11
OUT 2+
Configurable digital output 2 – positive pin
12
OUT 2-
Configurable digital output 2 – negative pin
16
OUT 3A
Configurable digital output 3 – polarity insensitive
17
OUT 3B
Configurable digital output 3 – polarity insensitive
18
EXT_TRIG A External trigger (polarity insensitive)
19
EXT_TRIG B External trigger (polarity insensitive)
6
ENC A
Encoder input signal (polarity insensitive)
10
ENC B
Encoder input signal (polarity insensitive)
14
IN3A
Input signal 3
15
IN4A
Input signal 4
24
IN_REF
Common reference of IN3 and IN4
9, 13
VS
VDC I/O supply voltage – positive pin
23, 25 GND
VDC I/O supply voltage – negative pin
Pin RS232
RS485
Full-Duplex
RS485 Half-
Duplex
20 mA C.L.
(INT-60 Only)
2 TX
TX485+ CLOUT+
3 RX
RX485+
CLIN+
4 RTS
TX485- RTX485- CLOUT-
5 CTS
RX485-
CLIN-
7
GND_ISO GND_ISO GND_ISO GND*
* For 20 mA C.L. connections, GND is the same of the scanner power supply.
Содержание DX8200
Страница 1: ...DX8200 Controller Reference Manual ...
Страница 2: ......
Страница 3: ...DX8200 Controller INSTALLATION MANUAL ...
Страница 6: ...iv GLOSSARY 41 INDEX 44 ...
Страница 12: ...x ...