![Datalogic DX8200 Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/datalogic/dx8200/dx8200_reference-manual_511921011.webp)
ix
The laser light is visible to the human eye and is emitted from the windows on the lower side
of the reader (Figure A, 3).
Warning labels indicating exposure to laser light and the device classification are applied
onto the body of the scanner (Figure A, 4 and 2):
LASER LIGHT
DO NOT STARE INTO BEAM
CLASS 2 LASER PRODUCT
MAXIMUM OUTPUT RADIATION 1 mW
EMITTED WAVELENGTH 630~680 nm
TO EN 60825-1:2001
AVOID EXPOSURE TO BEAM
CAUTION-CLASS 3B LASER LIGHT WHEN OPEN
LASER LIGHT EMITTED FROM THIS APERTURE
Model No.
Amp.
Serial No.
DATALOGIC S.P.A. Via Candini, 2
40012 Calderara di Reno - Bologna - Italy
Manufactured Volt
This product conforms to the applicable requirements
of 21CFR1040 at the date of manufacture.
Warning and device class labels
Disconnect the power supply when opening the device during maintenance or installation to
avoid exposure to hazardous laser light.
The laser diodes used in this device are classified as Class 3B laser products according to EN
60825-1 regulations and as Class IIIb laser products according to CDRH regulations. As it is
not possible to apply a classification label on the laser diodes used in this device, the
following label is reproduced here:
LASER LIGHT
AVOID EXPOSURE TO BEAM
CLASS 3B LASER PRODUCT
MAXIMUM OUTPUT RADIATION 35 mW
EMITTED WAVELENGTH 630~680 nm
TO EN 60825-1 (2001)
Laser diode class label
Any violation of the optic parts in particular can cause radiation up to the maximum level of
the laser diode (35 mW at 630~680 nm).
POWER SUPPLY
The supply voltage for correct operation of the scanner depends on the models:
-
between 20 and 30 VDC, supplied to the Lonworks Network connector, for
DX8200 Controller-X0X0 models
-
between 85 and 264 VAC, supplied through the VAC power cable, for DX8200
Controller-X0X1 models.
A security system allows the laser to activate only once the motor has reached the correct
rotational speed; consequently, the laser beam is generated after a slight delay from the
power on of the scanner.
During power up of the scanner there is a current peak of about 3A caused by the motor
startup.
Содержание DX8200
Страница 1: ...DX8200 Controller Reference Manual ...
Страница 2: ......
Страница 3: ...DX8200 Controller INSTALLATION MANUAL ...
Страница 6: ...iv GLOSSARY 41 INDEX 44 ...
Страница 12: ...x ...