23
READING DIAGRAMS
DS6400-105-0XX (Oscillating Mirror) – Resolution: 0.20 mm/8 mils
CONDITIONS
Code = Interleaved 2/5 or
Code 39
PCS = 0.90
Pitch angle = 0°
Skew angle = 10° - 20°
Tilt angle = 0°
8
6
10
10
(in)
0
14
20
(in)
16
18
22
24
0
35 40 45
50 55 60 65
70
(cm)
35
30
25
20
4
(cm)
15
5
0
-5
-10
-15
12
14
-4
-6
-2
0
2
75
80
28
26
30
32
-20
-8
40
16
85 90 95 100
36
34 38 40
Global Reading
Area
-25
-30
-35
-40
-10
-12
-14
-16
Focus
Pos ition = 60 cm
36
85
(in)
34
(cm)
90
80
75
70
65
60
26
24
28
30
32
55
22
0
40
45
50
55
60
65
70
75
(cm)
80 85 90
0
16
22
(in)
18
20
24
26
30
28
32 34 36
50
45
40
20
18
16
Min. Reading
Distance
Max. Reading
Distance
Reading distance