Datalogic DS6400 Скачать руководство пользователя страница 11

DS6400 QUICK GUIDE 

11

 

ACCESSORIES 

 

Name Description 

Part 

Number 

Power Supplies 

 

 

PG6002 

Single unit power supply (US) 

93ACC1718 

PG6001 

Single unit power supply (UK) 

93ACC1719 

PG6000 

Single unit power supply (EU) 

93ACC1720 

PWR-120 

J-box power unit 110/230 VAC  24 V  120 W 

93ACC1530 

PWR-240 

J-box power unit 110/230 VAC  24 V  240 W 

93ACC1070 

PWR-480A 

J-box power unit 110/230 VAC  24 V  480 W 

93ACC1850 

Cables and Terminators

 

 

 

BT-6000 Bus 

terminator 

93A051299 

CAB-6101 

9-pin scanner/scanner connection cable 1 m 

93A051220 

CAB-6102 

9-pin scanner/scanner connection cable 2 m 

93A051230 

CAB-6105 

9-pin scanner/scanner connection cable 5 m 

93A051240 

CAB-6112 

9-pin scanner to scanner no power cable 2 m 

93A051224 

CAB-6115 

9-pin scanner to scanner no power cable 5 m 

93A051225 

CAB-6305 

25-pin power cable Fam 6k 5 m 

93ACC1768 

CAB-6310 

25-pin power cable Fam 6k 10 m 

93ACC1752 

CAB-S01 

STD cable to CBX 1 m (25-pin to 25-pin) 

93A051351 

CAB-S02 

STD cable to CBX 2 m (25-pin to 25-pin) 

93A051352 

CAB-S05 

STD cable to CBX 5 m (25-pin to 25-pin) 

93A051353 

CAB-S10 

STD cable to CBX 10 m (25-pin to 25-pin) 

93A051354 

CAB-F01 

6K-8K FBUS cable to CBX 1 m (26-pin to 25-pin) 

93A051355 

CAB-F02 

6K-8K FBUS cable to CBX 2 m (26-pin to 25-pin) 

93A051356 

CAB-F05 

6K-8K FBUS cable to CBX 5 m (26-pin to 25-pin) 

93A051357 

CAB-6502 

Fam 6K-8K cross cable 2.5 m (9-pin to 17-pin) 

93A051288 

CAB-6505 

Fam 6K-8K cross cable 5 m (9-pin to 17-pin) 

93A051289 

Software Management 

 

 

Datalogic WebSentinel-005 

Supervisor (up to 5 arrays) 

93A101014 

Datalogic WebSentinel-010 

Supervisor (up to 10 arrays) 

93A101015 

Datalogic WebSentinel-020 

Supervisor (up to 20 arrays) 

93A101016 

Datalogic WebSentinel-032 

Supervisor (up to 32 arrays) 

93A101017 

Datalogic WebSentinel-064 

Supervisor (up to 64 arrays) 

93A101018 

Datalogic WebSentinel-128 

Supervisor (up to 128 arrays) 

93A101019 

Datalogic WebSentinel-256 

Supervisor (up to 256 arrays) 

93A101020 

Mirrors  

 

GFC-60 90° 

mirror 

93A201100 

GFC-600 

90° mirror close distance 

93A201102 

* Connection Boxes 

 

 

CBX100 

Compact Connection Box 

93A301067 

CBX500 

Modular Connection Box 

93A301068 

CBX800 

Gateway Connection Box 

93A301077 

BM100 Backup 

Module 

93ACC1808 

BA100 

DIN Rail Adapters for CBX 

93ACC1821 

BA200 

Bosch Adapters for CBX 

93ACC1822 

BA900 

Two Cable Glands Panel 

93ACC1847 

Sensors  

 

MEP-593 

Photocell kit – PNP (PH-1) 

93ACC1791 

MEP-543 

Photocell kit – NPN 

93ACC1728 

OEK-2 

Optical encoder kit (10 m cable + spring) 

93ACC1770 

OEK-1 

Optical encoder kit + 10 m cable 

93ACC1600 

Brackets  

 

FBK-6000 

Fast bracket kit (2 pcs) 

93ACC1721 

US-60 

Mounting bracket kit (5 pcs) for multisided stations 

890001020 

* DS6400 application software does not support any of the CBX500 Host Interface Module accessories nor the 
BM150 Display accessory. Use the CBX800 Gateway for Host Interface Applications, (Fieldbus and non 
Fieldbus). 

Содержание DS6400

Страница 1: ...twork applications For other types of installations such as ID NET Pass Through Multiplexer Layout etc refer to the DS6400 Reference Manual available on the CD For complete scanner configuration using...

Страница 2: ...t page which describes specific Info Features Applications Models Accessories and Downloads including the Genius utility program which allows device configuration using a PC It provides RS232 and Ethe...

Страница 3: ...se On LED Yellow 3 TX Data LED Green 2 Power On LED Red 4 LCD Display 5 Standard Ethernet DeviceNet Profibus Figure D Lonworks 9 pin Male Connector 1 Lonworks 9 pin Female Connector 2 Serial Interface...

Страница 4: ...External Trigger PS input CBX100 jumper set to accept scanner power Encoder connected to Input 2 Encoder input Synchronized Network with DS8100A Master and 6K Family Slaves Serial Host PWR 120 Local H...

Страница 5: ...rks system the network must be properly terminated by positioning a BT 6000 terminator on the DS6400 master reader BT 6000 female side and on the last slave reader BT 6000 male side BT 6000 Network Te...

Страница 6: ...rity insensitive only with CBX500 I4A IN 4A polarity insensitive only with CBX500 I34B IN 3B IN 4B Reference polarity insensitive only with CBX500 Outputs V Power Source Outputs V Power Reference Outp...

Страница 7: ...gnal 4 polarity insensitive 24 IN_REF Common reference of IN3 and IN4 polarity insensitive 9 13 VS Supply voltage positive pin 23 25 26 GND Supply voltage negative pin 14 1 25 13 25 pin male D sub Con...

Страница 8: ...5 5 pin male DeviceNet Connector NOTE The power supplied on pin V and V is used only to propagate power to the section of the DeviceNet board directly connected to the Bus It is completely isolated fr...

Страница 9: ...to 500 Kb s up to 12 Mb s Inputs Ext Trigger 1 Encoder 2 aux digital inputs optocoupled NPN or PNP Outputs 3 software programmable digital outputs optocoupled OPTICAL FEATURES Light Receiver Avalanche...

Страница 10: ...IRONMENTAL FEATURES Operating Temperature 0 to 40 C 32 to 104 F Storage Temperature 20 to 70 C 4 to 158 F Humidity 90 non condensing Ambient Light Immunity 3500 lux Vibration Resistance EN 60068 2 6 2...

Страница 11: ...7 CAB 6502 Fam 6K 8K cross cable 2 5 m 9 pin to 17 pin 93A051288 CAB 6505 Fam 6K 8K cross cable 5 m 9 pin to 17 pin 93A051289 Software Management Datalogic WebSentinel 005 Supervisor up to 5 arrays 93...

Страница 12: ...d lower limits of the oscillation by defining the top and bottom line limit angles When the oscillating mirror is programmed to read barcode labels at very small angles position the reader to assure a...

Страница 13: ...y the number of scans on the reading surface is increased Oscillating angles are selected in software where the minimum and maximum angles correspond to 2 5 and 37 5 The scanner can be tilted in order...

Страница 14: ...head 6 completely tighten the four fixing screws Step A Head Feature The following diagrams give the overall dimensions of the reader standard model oscillating mirror model and mounting bracket They...

Страница 15: ...ing the 45 Skew installation the scanner reading performance is not guaranteed to match that measured for the standard installation with Skew angle between 10 20 see reading diagrams NOTE The ST 210 m...

Страница 16: ...lopment has been based on the minimum distance detected Thus it can apply to the widest variety of applications Further developments of D Flash will be provided according to the specific application n...

Страница 17: ...8 9 11 13 15 17 5 7 8 10 11 13 0 30 9 10 12 14 16 18 6 7 9 10 12 13 0 33 9 11 13 14 16 18 6 8 9 11 12 14 0 38 10 11 13 15 17 19 7 8 10 11 13 14 0 50 13 14 15 17 19 21 8 9 11 12 14 15 0 72 17 18 19 21...

Страница 18: ...in 0 14 20 in 16 18 22 24 0 35 40 45 50 55 60 65 70 cm 35 30 25 20 4 cm 15 5 0 5 10 15 12 14 4 6 2 0 2 75 80 28 26 30 32 20 8 40 16 85 90 95 100 36 34 38 40 Global Reading Area 25 30 35 40 10 12 14 16...

Страница 19: ...90 100 cm 50 40 30 20 0 cm 10 10 0 20 30 40 16 20 16 20 12 8 4 110 120 40 36 44 48 50 24 60 24 130 140 56 52 Global Reading Area 60 Focus Position 90 cm 42 40 95 44 in 110 105 38 cm 100 90 85 80 75 70...

Страница 20: ...50 40 30 20 0 cm 10 10 0 20 30 40 16 20 16 20 12 8 4 120 130 44 40 48 52 50 24 60 24 140 150 60 56 Global Reading Area 60 Focus Position 110 cm 160 64 60 56 130 64 in 160 150 52 cm 140 120 110 100 90...

Страница 21: ...0 cm 10 10 0 20 30 40 16 20 16 20 12 8 4 120 130 44 40 48 52 50 24 60 24 140 150 60 56 Global Reading Area 60 F ocus Position 140 cm 160 64 170 180 68 72 70 28 70 28 60 56 130 64 in 160 150 52 cm 140...

Страница 22: ...0 20 30 40 16 20 16 20 12 8 4 120 130 44 40 48 52 50 24 60 24 140 150 60 56 Global Reading Area 60 Focus Position 120 cm 160 64 170 180 68 72 70 28 70 28 190 76 200 80 64 60 140 68 in 170 160 56 cm 1...

Страница 23: ...22 24 0 35 40 45 50 55 60 65 70 cm 35 30 25 20 4 cm 15 5 0 5 10 15 12 14 4 6 2 0 2 75 80 28 26 30 32 20 8 40 16 85 90 95 100 36 34 38 40 Global Reading Area 25 30 35 40 10 12 14 16 Focus Position 60...

Страница 24: ...60 70 80 90 100 cm 50 40 30 20 0 cm 10 10 0 20 30 40 16 20 16 20 12 8 4 110 120 40 36 44 48 50 24 60 24 130 140 56 52 Global Reading Area 60 Focus Position 95 cm 40 38 90 42 in 105 100 36 cm 95 85 80...

Страница 25: ...80 90 100 110 cm 50 40 30 20 0 cm 10 10 0 20 30 40 16 20 16 20 12 8 4 120 130 44 40 48 52 50 24 60 24 140 150 60 56 Global Reading Area 60 Focus Position 110 cm 160 64 60 56 130 64 in 160 150 52 cm 14...

Страница 26: ...0 40 30 20 0 cm 10 10 0 20 30 40 16 20 16 20 12 8 4 120 130 44 40 48 52 50 24 60 24 140 150 60 56 Global Reading Area 60 Focus Position 115 cm 160 64 170 180 68 72 70 28 70 28 60 56 130 64 in 160 150...

Страница 27: ...0 cm 10 10 0 20 30 40 16 20 16 20 12 8 4 120 130 44 40 48 52 50 24 60 24 140 150 60 56 Global Reading Area 60 Focus Position 115 cm 160 64 170 180 68 72 70 28 70 28 190 76 200 80 60 56 130 64 in 160 1...

Страница 28: ...witched off through a software command see also the Genius Help On Line AVOID EXPOSURE LASER RADIATION IS EMITTED FROM THIS APERTURE AVOID EXPOSURE LASER LIGHT IS EMITTED FROM THIS APERTURE Laser Safe...

Страница 29: ...to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment...

Отзывы: