INSTALLATION
27
2
2.6.4 RS485
Master/Slave
The RS485 master/slave connection is used to collect data from several scanners to
build either a multi-point or a multi-sided reading system; there can be one master
and up to 5 slaves connected together.
The slave scanners are connected together using RS485 half-duplex on the main
serial interface. Every slave scanner must have a multidrop address in the range 0-4.
The master scanner is also connected to the Host on the RS232 auxiliary serial
interface.
The External Trigger signal is unique to the system; there is a single reading phase
and a single message from the master scanner to the Host computer.
It is necessary to bring the External Trigger signal to all the scanners.
The main and auxiliary ports are connected as shown in the figure below.
1
2
3
Auxiliary serial interface
RS485HD Main serial interface
External Trigger
Host
DS2400
Slave
DS2400
Slave
DS2400
Master
1
1
1
2
3
LASER ON
PWR/TXD
EXT TRIG
GOOD READ
DS2400
LA
SE
R
O
N
PW
R/T
X
D
EX
T T
RIG
GO
O
D
R
E
A
D
DS
2
4
0
0
LAS
ER O
N
PWR
/TX
D
EXT
TR
IG
GOOD
REA
D
DS24
00
Figure 31 - RS485 Master/Slave layout