2.4 ELECTRICAL
CONNECTIONS
DS2400 25-pin connector models are equipped with a cable terminated by a 25-pin
female D-sub connector for connection to the power supply and input/output signals.
The details of the connector pins are indicated in the following table:
CAUTION
Do not connect GND and SGND to different (external) ground
references. GND and SGND are internally connected through
filtering circuitry which can be permanently damaged if subjected to
voltage drops over 0.8 Vdc.
Figure 11 - 25-pin female D-sub connector
25-pin D-sub connector pinout
Pin
Name
Function
13
VS
Power supply input v
25
GND
Power supply input voltage -
1
CHASSIS
Chassis Ground
9
VS
External Trigger supply v
18
EXT TRIG+
External T
19
EXT TRIG-
External Trigger -
8
OUT1 +
Output 1 +
11
OUT2 +
Output 2 +
12, 22
OUT REF
Output reference
20
RXAUX
Auxiliary RS232
21
TXAUX
Auxiliary RS232
23
CTSAUX
Auxiliary handshake RS232
24
RTSAUX
Auxiliary handshake RS232
6, 10, 14, 15,
16, 17
NC
Not Connected
Pin
RS232
RS485
Full-Duplex
RS485
Half-Duplex
20 mA C.L.
(INT-22 Only)
2
TX232
TX485+
CLOUT+
3
RX232
RX485+
CLIN+
4
RTS232
TX485-
RTX485-
CLOUT-
5
CTS232
RX485-
CLIN-
7
Main
interface
signals, see
par. 2.4.2.
SGND
SGND
SGND