Datalogic DS2100A Скачать руководство пользователя страница 2

 

 

DS2100A QUICK GUIDE

 

2  

 

Model Description: 

 

DS2100A - X X X X 

Optical Resolution

1 = Standard resolution 
2 = High resolution 

Communication Interface

2= RS232/RS4 RS232 aux

Optic Version

0 = Linear 
1 = Raster R1 

Performance 

0 = Standard 
4 = Testarossa ™ 

 

 

Reading Performance: 

Version 

Reading Distance 

Max Code 

Resolution 

mm (mils) 

Speed 

scans/s 

1XX0 

40 mm (1.6 in) - 300 mm (11.8 in) on 0.50 mm (20 mils) codes 

0.20 (8) 

500 to 800 

1XX4 

50 mm (1.8 in) - 310 mm (11.8 in) on 0.50 mm (20 mils) codes 

0.20 (8) 

800 to 1000

2XX0 

30 mm (1.2 in) - 90 mm (3.5 in) on 0.30 mm (12 mils) codes 

0.15 (6) 

500 to 800 

2XX4 

45 mm (1.8 in) - 100 mm (3.9 in) on 0.20 mm (8 mils) codes 

0.12 (5) 

800 to 1000

 

Technical Features: 

ELECTRICAL FEATURES

 

SOFTWARE FEATURES

 

Power Supply 

10 –30 Vdc 

Readable Codes 

 

Power Consumption 

Model XXX0: 3W 
Model XXX4: 5W 

Main Serial Interface 

Programmable: 
RS232; 
RS485 Full-Duplex/Half-
Duplex; 

Auxiliary Interface 

RS232 

*

*
*
*
*
*
*

EAN/UPC 

(including Add-on 2 and Add-on 5) 

Code 39 
2/5 Interleaved 
Code 128 
EAN 128 
Codabar 
Code 93 

Baudrates 

150 to 115200 

* = ACB readable 

ISBT 128 

Inputs 

 

 

Pharmacode 

 External Trigger 

(optocoupled NPN or PNP) 

Headers and

 

Up to four header and four 

 Voltage max. 

30 Vdc 

Terminators

 

terminator characters 

 Current Consumption 

25 mA 

Operating Modes

 

On-Line, Automatic, 

 max. 

 

 

Serial-On-Line, Test 

Outputs

)

 

 

Configuration Modes

Through menus using: 

 OUT1, 

OUT2 

(optocoupled) 

 

WinHost utility 
Host Mode (commands from  

  V

CE

 max. 

40 Vdc 

 

one of the serial ports) 

  Collector Current  

40 mA continuous; 

Code Selection 

Up to six different codes 

 max. 

130 mA pulsed 

 

during one reading phase 

  V

CE

 Saturation 

1V at 10 mA max. 

Decoding Safety 

Can enable multiple good 

  Power Dissipation  

90 mW at 40 °C 

 

reads of the same code 

 max. 

(Ambient temp.) 

Special Functions 

ACB (Advanced Code Builder)

 

 

 

Motor Off 

OPTICAL FEATURES 

 

 

Light Source 

semiconductor laser diode 

Parameter Storage 

Non-volatile internal EEPROM

Wavelength 

In the range 630 to 680 nm 

ENVIRONMENTAL FEATURES

 

Safety Class 

Class 2 - EN 60825-1; CDRH 

Operating 

0° to +40 °C (+32° to +104 °F)

 

 

Temperature

 

 

USER INTERFACE

 

Storage

 

-20° to +70 °C (-4° to +158 °F)

LED Indicators 

Laser ON, Good Read, 

Temperature  

 

External Trigger, 

Humidity max

 

90% non condensing 

 

Data TX / Power ON 

Vibration Resistance

IEC 68-2-6 test FC 1.5 mm; 

PHYSICAL FEATURES

 

 

10 to 55 Hz; 2 hours on each axis

Dimensions 

68x83.6x34 mm 

(2.7x3.29x1.3 in)

 

Shock Resistance 

IEC 68-2-27 test EA 30 G; 

Weight 

330 g. 

(11.64 oz)

 

 

11 ms; 3 shocks on each axis 

 

 

Protection Class 

IP65 

Содержание DS2100A

Страница 1: ...ed in the How To Build A Simple Interface Test Cable section of this guide The laser diode used in this device is classified as a class 3B laser product according to EN 60825 1 regulations and as a Class IIIb laser product according to CDRH regulations As it is not possible to apply a classification label on the laser diode used in this device the following label is reproduced below LASER LIGHT AV...

Страница 2: ... to four header and four Voltage max 30 Vdc Terminators terminator characters Current Consumption 25 mA Operating Modes On Line Automatic max Serial On Line Test Outputs Configuration Modes Through menus using OUT1 OUT2 optocoupled WinHost utility Host Mode commands from VCE max 40 Vdc one of the serial ports Collector Current 40 mA continuous Code Selection Up to six different codes max 130 mA pu...

Страница 3: ...see the relative C Box Installation Manual CAUTION Do not connect GND and SGND to different external ground references GND and SGND are internally connected through filtering circuitry which can be permanently damaged if subjected to voltage drops over 0 8 Vdc The details of the connector pins are indicated in the following table 25 pin D sub female connector pinout Pin Name Function 13 VS Power s...

Страница 4: ...wer MEP 543 Connector DS2100A 18 19 5V VS 9 25 GND EXT TRIG EXT TRIG 4 3 2 1 brown white blue Input NPN command using MEP 543 Photocell OUTPUT EXTERNAL TRIGGER DS2100A Signal 18 19 5V VS 9 25 GND Ground V EXT TRIG EXT TRIG Input NPN command using DS2100A power USER INTERFACE 8 11 12 22 OUT REF DS2100A Vext 40 Vdc max C E Output open collector connections INPUT PNP 18 19 5V DS2100A EXTERNAL TRIGGER...

Страница 5: ...e RS232 c Main Serial Interface RS485 Half Duplex dAuxiliary Serial Interface RS232 dAuxiliary Serial Interface Local Echo RS232 eExternal Trigger for On Line Mode eExternal Trigger for On Line Mode RS232 Master slave layout RS485 Master slave layout c Main Serial Interface Slaves RS232 only c Auxiliary Serial Interface RS232 dAuxiliary Serial Interface RS232 d Main Serial Interface RS485 Half Dup...

Страница 6: ...Winhost 2 1 0 1 5 4 3 2 3 4 5 in 120 100 80 60 40 20 0 20 40 60 80 100 120 mm 0 1 3 2 10 6 in 4 5 7 8 9 0 20 40 60 80 100 120 140 160 180 200 220 240 260 mm 280 11 300 12 0 20 mm 8 mils 0 50 mm 20 mils 0 30 mm 12 mils 0 35 mm 14 mils DS2100A 1200 Reading Distance vs Scanning Speed 0 1 3 2 10 6 in 4 5 7 8 9 0 20 40 60 80 100 120 140 160 180 200 220 240 260 mm 0 20 mm 280 11 300 12 0 30 mm 0 35 mm 0...

Страница 7: ...Standard Parameter selectable in Winhost 1 0 2 1 2 in 0 1 5 3 in 2 4 0 10 20 30 40 50 60 70 80 90 100 110 120 130 mm 60 50 40 30 20 10 0 10 20 30 40 50 60 mm 0 15 mm 6 mils 0 20 mm 8 mils 0 30 mm 12 mils DS2100A 2200 Reading Distance vs Scanning Speed 0 1 5 3 in 2 4 0 10 20 30 40 50 60 70 80 90 100 110 120 130 m m 0 30 m m 0 20 m m 0 15 m m 500 scan s s 800 scan s s C od e R eso lu tio n D istan c...

Страница 8: ...140 160 180 200 220 240 260 mm 120 100 80 60 40 20 0 20 40 60 80 100 120 mm 280 11 300 12 0 15 mm 6 mils 0 20 mm 8 mils 0 30 mm 12 mils 0 50 mm 20 mils DS2100A 2204 Testarossa High Resolution 1000 scans s CONDITIONS Optic Version Linear Code Interleaved 2 5 or Code 39 PCS 0 90 Pitch angle 0 Skew angle 15 Tilt angle 0 Code Resolution High for 0 15 mm 6 mils codes and smaller Standard for 0 20 mm 8 ...

Страница 9: ...connector Pin Name Pin Name 2 RX 3 RX 3 TX 2 TX 5 GND 7 GND 7 RTS 4 RTS 8 CTS 5 CTS How To Build A Simple Interface Test Cable The following wiring diagrams show a simple test cable including power external push button trigger and PC RS232 COM port connections 25 pin D sub male 7 20 SGND RXAUX TXAUX 21 DS2100A 25 13 GND VS 9 pin D sub female GND TX RX PC 2 3 5 18 9 EXT TRIG VS Power Supply VS 10 3...

Страница 10: ...ing to electromagnetic compatibility and product safety Basée sur la législation des Etates membres relative à la compatibilité électromagnétique et à la sécurité des produits Über die Annäherung der Gesetze der Mitgliedsstaaten in bezug auf elektromagnetische Verträglichkeit und Produktsicherheit entsprechen Basado en la aproximación de las leyes de los Países Miembros respecto a la compatibilida...

Отзывы: