background image

 

DS2100A 

Laser Barcode Reader 

Quick Reference Guide

 

The scanner is classified as a Class 2 laser 
product according to EN 60825-1 regulations 
and as a Class II laser product according to 
CDRH regulations. 
 
Disconnect the power supply when opening the 
device during maintenance or installation to 
avoid exposure to hazardous laser light. 
 
There is a safety device which allows the laser to 
be switched on only if the motor is rotating above 
the threshold for its correct scanning speed. 
 
The laser beam can be switched off through a 
software command (see also the WinHost Help 
On Line). 

 

 

 Figure 

A

 

 

 

Warning and Device Class Labels 

 

 

Mounting Holes 

Laser On LED 

Good Read LED 

External Trigger LED 

Power On / Data TX LED

Warning and Device Class Labels

Accessory Mounting Holes

Laser Beam Output Window

 

For further details on product installation, see the 
complete Installation Manual. 

DS2100A can be configured through the WinHost 
Windows-based software program available on the 
installation CD-ROM. 

For configuration it is necessary to create a cable 
connecting the scanner to the PC as indicated in the 
“How To Build A Simple Interface Test Cable” section of 
this guide. 

 

The laser diode used in this device is 
classified as a class 3B laser product 
according to EN 60825-1 regulations and as a 
Class IIIb laser product according to CDRH 
regulations. As it is not possible to apply a 
classification label on the laser diode used in 
this device, the following label is reproduced 
below. 

 

LASER LIGHT 

AVOID EXPOSURE TO BEAM 
CLASS 3B LASER PRODUCT 

MAX. OUTPUT RADIATION  35 mW 

EMITTED WAVE LENGTH  630~680 nm 

TO EN 60825-1 (2001) 

 

Laser Diode Class Label 

 

Any violation of the optic parts in particular 
can cause radiation up to the maximum level 
of the laser diode (35 mW at 630 to 680 nm). 

POWER SUPPLY 

-  This product is intended to be installed by Qualified 

Personnel only. 

- All 

Models: 

  This accessory device is intended to be supplied by a UL 

Listed or CSA Certified Power Unit with «Class 2» or LPS 
power source which supplies power directly to the 
scanner via the 25-pin connector.

 

 

 

CAUTION-CLASS 3B LASER LIGHT 

WHEN OPEN AVOID EXPOSURE TO BEAM

This product conforms to the applicable 
requirements of 21CFR1040 at the date 
of manufacture. 

LASER LIGHT 

DO NOT STARE INTO BEAM 

CLASS 2 LASER PRODUCT 

MAX. OUTPUT RADIATION  1 mW 

EMITTED WAVE LENGTH  630~680 nm 

TO EN 60825-1:2001 

R

C

US

218441

N2468

5

4

2

3

8

7

6

Содержание DS2100A

Страница 1: ...ed in the How To Build A Simple Interface Test Cable section of this guide The laser diode used in this device is classified as a class 3B laser product according to EN 60825 1 regulations and as a Class IIIb laser product according to CDRH regulations As it is not possible to apply a classification label on the laser diode used in this device the following label is reproduced below LASER LIGHT AV...

Страница 2: ... to four header and four Voltage max 30 Vdc Terminators terminator characters Current Consumption 25 mA Operating Modes On Line Automatic max Serial On Line Test Outputs Configuration Modes Through menus using OUT1 OUT2 optocoupled WinHost utility Host Mode commands from VCE max 40 Vdc one of the serial ports Collector Current 40 mA continuous Code Selection Up to six different codes max 130 mA pu...

Страница 3: ...see the relative C Box Installation Manual CAUTION Do not connect GND and SGND to different external ground references GND and SGND are internally connected through filtering circuitry which can be permanently damaged if subjected to voltage drops over 0 8 Vdc The details of the connector pins are indicated in the following table 25 pin D sub female connector pinout Pin Name Function 13 VS Power s...

Страница 4: ...wer MEP 543 Connector DS2100A 18 19 5V VS 9 25 GND EXT TRIG EXT TRIG 4 3 2 1 brown white blue Input NPN command using MEP 543 Photocell OUTPUT EXTERNAL TRIGGER DS2100A Signal 18 19 5V VS 9 25 GND Ground V EXT TRIG EXT TRIG Input NPN command using DS2100A power USER INTERFACE 8 11 12 22 OUT REF DS2100A Vext 40 Vdc max C E Output open collector connections INPUT PNP 18 19 5V DS2100A EXTERNAL TRIGGER...

Страница 5: ...e RS232 c Main Serial Interface RS485 Half Duplex dAuxiliary Serial Interface RS232 dAuxiliary Serial Interface Local Echo RS232 eExternal Trigger for On Line Mode eExternal Trigger for On Line Mode RS232 Master slave layout RS485 Master slave layout c Main Serial Interface Slaves RS232 only c Auxiliary Serial Interface RS232 dAuxiliary Serial Interface RS232 d Main Serial Interface RS485 Half Dup...

Страница 6: ...Winhost 2 1 0 1 5 4 3 2 3 4 5 in 120 100 80 60 40 20 0 20 40 60 80 100 120 mm 0 1 3 2 10 6 in 4 5 7 8 9 0 20 40 60 80 100 120 140 160 180 200 220 240 260 mm 280 11 300 12 0 20 mm 8 mils 0 50 mm 20 mils 0 30 mm 12 mils 0 35 mm 14 mils DS2100A 1200 Reading Distance vs Scanning Speed 0 1 3 2 10 6 in 4 5 7 8 9 0 20 40 60 80 100 120 140 160 180 200 220 240 260 mm 0 20 mm 280 11 300 12 0 30 mm 0 35 mm 0...

Страница 7: ...Standard Parameter selectable in Winhost 1 0 2 1 2 in 0 1 5 3 in 2 4 0 10 20 30 40 50 60 70 80 90 100 110 120 130 mm 60 50 40 30 20 10 0 10 20 30 40 50 60 mm 0 15 mm 6 mils 0 20 mm 8 mils 0 30 mm 12 mils DS2100A 2200 Reading Distance vs Scanning Speed 0 1 5 3 in 2 4 0 10 20 30 40 50 60 70 80 90 100 110 120 130 m m 0 30 m m 0 20 m m 0 15 m m 500 scan s s 800 scan s s C od e R eso lu tio n D istan c...

Страница 8: ...140 160 180 200 220 240 260 mm 120 100 80 60 40 20 0 20 40 60 80 100 120 mm 280 11 300 12 0 15 mm 6 mils 0 20 mm 8 mils 0 30 mm 12 mils 0 50 mm 20 mils DS2100A 2204 Testarossa High Resolution 1000 scans s CONDITIONS Optic Version Linear Code Interleaved 2 5 or Code 39 PCS 0 90 Pitch angle 0 Skew angle 15 Tilt angle 0 Code Resolution High for 0 15 mm 6 mils codes and smaller Standard for 0 20 mm 8 ...

Страница 9: ...connector Pin Name Pin Name 2 RX 3 RX 3 TX 2 TX 5 GND 7 GND 7 RTS 4 RTS 8 CTS 5 CTS How To Build A Simple Interface Test Cable The following wiring diagrams show a simple test cable including power external push button trigger and PC RS232 COM port connections 25 pin D sub male 7 20 SGND RXAUX TXAUX 21 DS2100A 25 13 GND VS 9 pin D sub female GND TX RX PC 2 3 5 18 9 EXT TRIG VS Power Supply VS 10 3...

Страница 10: ...ing to electromagnetic compatibility and product safety Basée sur la législation des Etates membres relative à la compatibilité électromagnétique et à la sécurité des produits Über die Annäherung der Gesetze der Mitgliedsstaaten in bezug auf elektromagnetische Verträglichkeit und Produktsicherheit entsprechen Basado en la aproximación de las leyes de los Países Miembros respecto a la compatibilida...