COMMON FEATURES
Keypad and Display
The SC6000 keypad allows entering a menu to select one of the functions described in the following paragraphs.
STANDARD MODE
Upon startup, the diagnostic mask window is visualized by default. Using the UP and DOWN keys it is possible to
scroll the other windows following this order:
1)
Diagnostic Mask Window
2)
Reading Performance Window
3)
Reading Mask Window
4)
I/O Status Window
5)
System Info Window
6)
Last Codes & Read Mask
7) Alarms
Diagnostic Mask Window (Default Window)
This window illustrates the status of each node (of each scanner of the cluster) according to the following
convention:
" - "
From the startup the node NID has not been discovered.
" ? "
At the startup of the system the NID has been discovered but the node does not
answer to the master.
" * "
The node status is OK.
" ! "
The node returns an error code to the diagnostic Laser Off.
" & "
The node returns an error code to the diagnostic Motor Off.
" % "
The node is in monitor mode.
"Scan A B C"
The specific scanners (indicated by each letter) have been discovered.
"Status ***"
The scanner status is ok.
"Empty scan cluster"
No scanner has been discovered within the cluster.
"No slave expected"
A scanner not expected by the system configuration has been discovered.
“Energy Saving”
The Energy Saving feature (see Genius™ program Help On-Line) has been
activated.
Reading Performance Window
This window displays the following data:
•
Number of the processed parcels
•
Good Read Rate
•
No Read Rate
•
Multiple Read Rate
Reading Mask Window
This window indicates the node that performed a reading of the codes enabled on the master.
The following indicators are used:
" * "
The node read a barcode enabled on the master.
" - "
The node read no barcode.
I/O Status Window
This window provides data concerning the conveyor speed and the digital input/output status.
System Info Window
This window provides information about the software release.
Last Codes & Read Mask
This window is available only when enabling the “Last Code & Reading Mask Window” parameter from the
Genius™ configuration program.
The following data are shown:
•
Window title
•
Last read code
•
List of nodes that performed a reading of the codes enabled on the master
•
Statistics (No Read rate, Partial Read rate, Multiple Read rate) calculated on the last 100 codes or in
continuous mode depending on the parameter selection.
12