background image

 

 
 

CBX100 

Installation Manual 

 
The CBX100 is a connection box which can be used as an accessory to 
facilitate system connections for installation and device replacement of 
several Datalogic family reading devices. 
 
System cabling is made through spring clamp terminal blocks inside the 
CBX100 while the reading device is connected to the CBX100 through a 25-
pin connector on the housing. 
 
A 9-pin connector placed inside the CBX100 facilitates connection between 
an external PC and the auxiliary serial interface of the reading device for 
configuration or data monitoring. 
 
CBX100 can also house an accessory Backup and Restore Module to make 
system maintenance extremely quick and easy. 
 
 

GENERAL VIEW 

CBX100 

 

 

Figure A 

 

 

Indicator LEDs 

Cover Screws (2) 

Compression Connectors (4) 

25-pin Device Connector 

 

 
 
 

 

Figure B 

 

Power switch (ON/OFF) 


2  Auxiliary Port Connector 
3  Mounting Holes (2) 

4  ID-NET™Termination 

Resistance Switch 

Indicator LEDs 

6  Backup Module Connector 

Spring Clamp Terminal Blocks 

RS485 Termination 
Resistance Switch

 

Power Source Selector 

Shield to Protection Earth Selector 

10 

Chassis Grounding Selector 

11 

 

SAFETY PRECAUTIONS 

 

ATTENTION: READ THIS INFORMATION BEFORE INSTALLING THE PRODUCT 

 

POWER SUPPLY 

 

This product is intended to be installed by Qualified Personnel only. 

This device is intended to be supplied by a UL Listed NEC Class 2 power 
source. 

 

 

CAUTION 

Total power consumption is given by adding the 
CBX100 power consumption to that of all the devices 
powered through the CBX100 (reading device, P.S., 
I/O). Refer to the manual of the connected devices for 
details about minimum/maximum supply voltage and 
power consumption. 

 

Each CBX100 supports only 1 single reading system 
accessories. 

 
 

SUPPORTED READING DEVICE MODELS 

 
The CBX100 can be directly connected to the following readers through the 
25-pin connector illustrated in Figure A. 
 

Linear Scanners 

2D Readers 

DS2100N DS2400N  DS4800  DS6300  MATRIX-1000 MATRIX-2000

DS6400 DX6400 DS8100A 

DX8200A 

 

MATRIX 

400 

 

 

NOTE 

CBX100 is backward compatible with DS4600A, 
DS2100N/DS2400N (black body), and DS1100/DS2200 
10-30 Vdc model reading devices using the ADP-MM1 
25-pin gender changer. See the Gender Changer 
documentation for the relative CBX100 pinout. 

 
 

OPENING THE CBX100 

 
To install the CBX100 or during normal maintenance, it is necessary to 
open it by unscrewing the two cover screws: 
 

 

CAUTION 

The CBX100 must be disconnected from the power 
supply during this operation. 

 
 

MECHANICAL INSTALLATION 

 
CBX100 can be mounted to various wooden or plastic surfaces using the two 
self-threading screws (3.9 x 45 mm) and washers provided in the package. 
 
Mounting to other surfaces such as concrete walls or metallic panels 
requires user-supplied parts (screws, screw anchors, nuts, etc). A mounting 
template is included in the package to facilitate hole drilling alignment. 
 
CBX100 can also be mounted to a DIN rail or a Bosch Frame using the 
following mounting accessories: BA100 (93ACC1821), BA200 (93ACC1822). 
 
The diagram below gives the overall dimensions of the CBX100 and shows 
the two mounting through-holes. 
 

113

.5

 [

4.4

7]

43.3

 [1.71]

41.4

 [1.63]

4

 [0.16]

4

 [0.16

]

62

 [2.4]

138

 [5.4]

128

 [5.0]

30.

8

 [1.21

]

 

Figure 1 - Overall Dimensions 

ELECTRICAL CONNECTIONS AND SETUP 

 
The following figure shows a typical layout. 
 

 

Figure 2 – System Layout 

 
The dotted line in the figure refers to an optional (temporary) hardware 
configuration in which a portable PC can be quickly connected to the 
CBX100 (and consequently to the reading device auxiliary interface) 
through the internal 9-pin connector. This allows monitoring of the data 
transmitted by the reading device or configuration through the utility 
program (see the reading device Installation Manual for more details). The 
reading device auxiliary interface signals are also available on the internal 
spring clamp connectors. 
 
After making system cabling and switch settings, connect the reading 
device to the 25-pin connector on the CBX100 housing. 
 
Switch ON the CBX100 power switch (see Figure 3). The Power LED turns 
on (blue) when the power connection has the correct polarity. The Power 
LED turns on (red) in case of wrong polarity. 
 
After system functioning has been verified, close the CBX100 using the 2 
cover screws. 
 
 

POWER SUPPLY 

 
Power is supplied to the CBX100 through the Vdc and GND pins provided 
on the spring clamp connector. 
 
The power switch (see Figure 3) switches the power supply ON or OFF for 
both the CBX100 and the connected reading device. 
 

 

CAUTION 

The power switch does not control power to the 
Vdc/GND, +V/-V spring clamps, therefore any devices 
connected to these signals (i.e. external trigger, 
encoder, etc.), are live and are not protected from 
polarity inversion. Disconnect the power supply when 
working inside the CBX100. 

 
 

OFF

ON

 

CBX100

POWER SUPPLY 

GND 

GND 

Vdc

V+  (10 - 30 Vdc) 

Earth 

Earth Ground

 

Figure 3 - Power Switch ON/OFF Positions and Connections 

 
 

 

NOTE 

Vdc is electrically connected to +V, just as GND is 
electrically connected to -V. This is useful for supplying 
external trigger, inputs and outputs from the CBX100 
power source, hV and -V signals should not be 
used as power supply inputs to the CBX100. 

 

The power supply must be between 10 and 30 Vdc only. 

 
 

 

NOTE 

To avoid electromagnetic interference: 

Connect CBX100 Protection Earth (Earth) to a good 
earth ground. 

Connect the reading device chassis to earth ground 
through the jumper, (default setting, see Figure 7). 

Connect the Network Cable Shield (Shield) to Filtered 
Earth through the jumper (default setting, see Figure 6). 

SYSTEM WIRING 

 
The connection and wiring procedure for CBX100 is described as follows: 

1)  Open the CBX100 by unscrewing the 2 cover screws. 

2)  Verify that the CBX100 power switch is off (see Figure 3). 

3)  Unscrew the compression connectors and pass all the system cables 

through them into the CBX100 housing. 

4)  To connect the power and input/output signals: 

• 

Prepare the individual wires of the system cables by stripping the 
insulation back approximately 1 cm. 

• 

Using a device such as a screwdriver, push down on the lever 
directly next to the clamp (see Figure 4). 

• 

Insert the wire into the clamp and release the lever. 

The wire will now be held in the spring clamp. 

5)  Tighten the compression connector nuts so that the internal glands seal 

around the cables. 

 

 

Figure 4 - System Cable Connections 

 

Flexible stranded wire should be used and must meet the following 
specifications. 
All positions: 

24 - 16 AWG 

0.2 - 1.5 mm² 

The CBX100 spring clamp connector pinouts are indicated in the Pinout 
table. 
 

Refer to the reading device Installation Manual for signal details. 

 

Pinouts 

Group Name Function 

Vdc 

Power Supply Input V 

GND 

Power Supply Input Voltage - 

Input 
Power 

Earth 

Protection Earth Ground 

+V 

Power Source – External Trigger 

I1A 

External Trigger A  (polarity insensitive) 

I1B 

External Trigger B  (polarity insensitive) 

External 
Trigger 
Input 

-V 

Power Reference – External Trigger 

+V 

Power Source – Inputs 

I2A 

Input 2 A  (polarity insensitive) 

I2B 

Input 2 B  (polarity insensitive) 

Generic 
Input 

-V 

Power Reference – Inputs 

+V 

Power Source – Outputs 

-V 

Power Reference – Outputs 

O1+ 

Output 1 + 

O1- 

Output 1 - 

O2+ 

Output 2 + 

Outputs 

O2- 

Output 2 - 

TX 

Auxiliary Interface TX 

RX 

Auxiliary Interface RX 

Auxiliary 
Interface 

SGND 

Auxiliary Interface Reference 

REF Network 

Reference 

ID+ 

ID-NET™ N 

ID-NET™ 

ID- 

ID-NET™ Network - 

Network 

Shield 

Network Cable Shield 

 

 

RS232 RS485FD 

RS485HD 

 TX 

TX+ 

RTX+ 

 RTS 

TX- 

RTX- 

 RX 

*RX+  

 CTS 

*RX-  

Main 
Interface 

 SGND 

SGND 

SGND 

 

The input power signals 

Vdc

GND

 and 

Earth

 as well as the network signals 

REF

ID+

ID-

 and 

Shield

 are repeated to facilitate system cabling. In this way the power and 

network busses can enter and exit the CBX100 from different spring clamps but be 
physically connected together. 

Reading Device 
Configuration PC 

PWR

Scanner 

CBX100

Scanner 
Auxiliary 
Interface

PS, I/O, Main Interface

10 

11 

Mounting 
Holes 

Содержание CBX100

Страница 1: ...d the auxiliary serial interface of the reading device for configuration or data monitoring CBX100 can also house an accessory Backup and Restore Module to make system maintenance extremely quick and easy GENERAL VIEW CBX100 Figure A Indicator LEDs 1 Cover Screws 2 2 Compression Connectors 4 3 25 pin Device Connector 4 Figure B Power switch ON OFF 1 2 Auxiliary Port Connector 3 Mounting Holes 2 5 ...

Страница 2: ...black body and DS1100 DS2200 10 30 Vdc model reading devices using the ADP MM1 25 pin gender changer See the Gender Changer documentation for the relative CBX100 pinout OPENING THE CBX100 To install the CBX100 or during normal maintenance it is necessary to open it by unscrewing the two cover screws CAUTION The CBX100 must be disconnected from the power supply during this operation MECHANICAL INST...

Страница 3: ...ns provided on the spring clamp connector The power switch see Figure 3 switches the power supply ON or OFF for both the CBX100 and the connected reading device CAUTION The power switch does not control power to the Vdc GND V V spring clamps therefore any devices connected to these signals i e external trigger encoder etc are live and are not protected from polarity inversion Disconnect the power ...

Страница 4: ...to the reading device Installation Manual for signal details Pinouts Group Name Function Vdc Power Supply Input Voltage GND Power Supply Input Voltage Input Power Earth Protection Earth Ground V Power Source External Trigger I1A External Trigger A polarity insensitive I1B External Trigger B polarity insensitive External Trigger Input V Power Reference External Trigger V Power Source Inputs I2A Inp...

Страница 5: ...IS GROUNDING JUMPER SETTINGS The reading device chassis grounding method can be selected by positioning a jumper see Figure 7 In this way the reading device chassis can be connected to earth ground only if pin Earth is connected to a good earth ground For all reading devices except 6K 8K the chassis can alternatively be connected to the power supply ground signal GND or it can be left floating but...

Страница 6: ...s termination resistor for RS485 Half Duplex Multidrop applications CAUTION In Multiplexer applications the termination resistor must be enabled ONLY on the last device of the chain the farthest away from the Multiplexer assuming the Multiplexer is the first device of the chain On all the other devices this resistor MUST NOT be enabled OFF BM100 BACKUP AND RESTORE MODULE ACCESSORY The BM100 Backup...

Страница 7: ... 5 0 3 A Limited Current Consumption CBX reading device consumption see related manual 2 5 A Max USER INTERFACE LED Indicators Power On Polarity Error blue red Trigger yellow IN2 green OUT1 yellow OUT2 green PHYSICAL FEATURES Mechanical Dimensions 138 x 128 x 62 mm 5 4 x 5 x 2 4 in Weight about 380 g 13 40 oz ENVIRONMENTAL FEATURES Operating Temperature 0 to 50 C 32 to 122 F Storage Temperature 20...

Страница 8: ...guiente 89 336 EEC EMC Directive e 92 31 EEC 93 68 EEC emendamenti successivi and further amendments et ses successifs amendements und späteren Abänderungen y succesivas enmiendas Basate sulle legislazioni degli Stati membri in relazione alla compatibilità elettromagnetica ed alla sicurezza dei prodotti On the approximation of the laws of Member States relating to electromagnetic compatibility and...

Отзывы: