background image

CATCHER™ D531 SERIES 

 

First Start-Up 

 

Connect Catcher™ D531 

to Host

 

Does a dialog 

box appear 

warning that Bus 

power is not 

sufficient?

 

Select desired USB 

interface code  

(USB-KBD is default)

Disconnect scanner 

at Host

 

Connect external 

power supply to 

cable and power up

Reconnect reader 

cable to Host and 

close dialog box

 

NO

YES

Read test codes. 

Scanner is READY

Load drivers 

(if required)

 

Load drivers 

(if required)

Green LED blinks 

Green LED off - BEEP OK

BEEP OK 

Green LED off 

 

 
 
Successive start-ups will automatically recognize the previously loaded drivers. 
If external power is used, verify that external power is already supplied. 
 
 

Successive Start-Ups 

 

NO 

YES

Read test codes. 

Scanner is READY

Green LED blinks 

Green LED off - BEEP OK 

BEEP OK 

Connect Catcher™ D531 

to Host

 

Disconnect scanner 

at Host

 

Connect external 

power supply to 

cable and power up

Reconnect reader 

cable to Host and 

close dialog box

 

Does a dialog box 

appear warning 

that Bus power is 

not sufficient?

 

Green LED off 

 

 

 

Содержание CATCHER D531 Series

Страница 1: ...CATCHER D531 SERIES Quick Reference ...

Страница 2: ......

Страница 3: ...CATCHER D531 SERIES QUICK REFERENCE ...

Страница 4: ...without prior notification Datalogic shall not be liable for technical or editorial errors or omissions contained herein nor for incidental or consequential damages resulting from the use of this material Product names mentioned herein are for identification purposes only and may be trademarks and or registered trademarks of their respective companies Datalogic S p A 2005 820001491 Rev A ...

Страница 5: ...activation 5 Interface Selection 6 USB Interface Configuration 6 USB Interface Selection 8 USB Keyboard Nationality 9 RS232 Reader Configuration 10 Wedge Interface Selection 11 Wedge Keyboard Nationality 14 Default Values 15 Operating Test 17 Technical Features 18 Reading Diagram 19 Scanner Data Entry 20 Warranty 20 Services and Support 21 Patents 21 Compliance 21 iii ...

Страница 6: ...na di questo manuale Collegarsi a www datalogic com F La version française de ce manuel est disponible sur Internet Cliquez sur www datalogic com D Im Internet finden sie die deutschsprachige Version dieses Handbuches Adresse www datalogic com E Está disponible la versión en español de este manual en la siguiente dirección de Internet www datalogic com iv ...

Страница 7: ...d held e g a Handsfree scanning by presenting the item to the scanner using a sweeping curved motion towards the scanner window b You can also use it as a hand held device by presenting the scanner to the item using a sweeping curved motion towards the item SLEEP STATE After a default stand by timeout the scanner enters a Sleep state for minimum power consumption in which the scanner Laser is OFF ...

Страница 8: ...ll appear but barcodes cannot be decoded 2 Position the presentation scanner over the code to read and press the trigger within 5 seconds to decode the code When using the scanner for data entry a programmable timeout is provided to assure that Catcher will return to raster mode if barcode reading is not successful in single line Single Line Decoding Duration Also a programmable timeout is availab...

Страница 9: ...nner position in relation to the counter surface 2 Pay attention to the product flow the distance to the counter edge and convenience for the operator RS232 Connection With the RS232 cable this accessory device is intended to be supplied by a UL Listed or CSA Certified Direct Plug in Power Unit marked Class 2 rated 5 V minimum 350 mA USB Connection if required With the USB cable this accessory dev...

Страница 10: ... is intended to be connected to either a UL Listed or CSA Certified Computer which supplies power directly to the reader or a UL Listed or CSA Certified Direct Plug in Power Unit marked Class 2 rated 5 V minimum 350 mA CONNECTING DISCONNECTING THE CABLES Interface Cable Connector EAS Connector 4 ...

Страница 11: ...NER SEE CONNECTIONS INTERFACE CABLE TAG DEACTIVATION The tag deactivation is performed at a distance a few centimeters Simply bring the Catcher closer to the tag or present the tag to the scanner Successful deactivation is signaled by an audible tone see your EAS System manual 5 ...

Страница 12: ...ically or will be suggested by the O S and should therefore be selected from the dialog box the first time only If the Host supplies sufficient power to the reader the start up phase ends correctly the green LED stops blinking and the reader emits the beep OK signal If the Host does not supply sufficient power to the reader a dialog box will appear on the Host and the reader will be blocked green ...

Страница 13: ... drivers if required Green LED blinks Green LED off BEEP OK BEEP OK Green LED off Successive start ups will automatically recognize the previously loaded drivers If external power is used verify that external power is already supplied Successive Start Ups NO YES Read test codes Scanner is READY Green LED blinks Green LED off BEEP OK BEEP OK Connect Catcher D531 to Host Disconnect scanner at Host C...

Страница 14: ...USB KBD APPLE Ì UA05 FÎ USB COM Ì UA02 4Î USB IBM Table Top Ì UA00 Î USB IBM Hand Held Ì UA01 Î When configuring USB COM the relevant files and drivers must be installed from the USB Device Installation software which can be downloaded from the web site http www datalogic com 8 ...

Страница 15: ...NATIONALITY USB KBD users should select one of the following keyboard nationality codes Belge Ì FJ7 8Î Deutsch Ì FJ3 Î English Ì FJ4 Î Español Ì FJ6 3Î Français Ì FJ2 ÊÎ Italiano Ì FJ1 ÅÎ Svenskt Ì FJ5 Î USA Ì FJ0 Î Japanese Ì FJ8 Î 9 ...

Страница 16: ...IGURATION Read the restore default code then read the interface selection code for your application RESTORE DEFAULT Ì oÎ RS232 INTERFACE Standard Ì CP0 Î POS TERMINALS Nixdorf Mode A Ì CM2 Î Fujitsu Ì CM1 ÈÎ ICL Mode Ì CM0 ÃÎ 10 ...

Страница 17: ...Read the restore default code then read the interface selection code for your application RESTORE DEFAULT Ì oÎ WEDGE INTERFACE IBM AT or PS 2 PCs Ì CP500 aÎ IBM XT Ì CP503 vÎ PC Notebook Ì CP505 ÈÎ IBM SURE1 Ì CP506 Î IBM Terminal 3153 Ì CP504 Î 11 ...

Страница 18: ...rd Ì CP502 oÎ make break keyboard Ì CP501 hÎ KEYBOARD TYPE advanced keyboard Ì FK1 ÉÎ typewriter keyboard Ì FK0 ÄÎ ALT MODE The following interface selection allows barcodes sent to the PC to be interpreted correctly independently from the Keyboard Nationality used You do not need to make a Keyboard Nationality selection default Num Lock Unchanged Make sure the Num Lock key on your keyboard is ON ...

Страница 19: ...DGE INTERFACE CONTINUED WYSE TERMINALS ANSI Keyboard Ì CP509 9Î PC Keyboard Ì CP510 gÎ ASCII Keyboard Ì CP511 nÎ VT220 style Keyboard Ì CP514 ÇÎ DIGITAL TERMINALS VT2xx VT3xx VT4xx Ì CP512 uÎ APPLE APPLE ADB Bus Ì CP513 Î 13 ...

Страница 20: ... the following codes the one that matches your Keyboard Nationality Belge Ì FJ7 8Î Deutsch Ì FJ3 Î English Ì FJ4 Î Español Ì FJ6 3Î Français Ì FJ2 ÊÎ Italiano Ì FJ1 ÅÎ Svenskt Ì FJ5 Î USA Ì FJ0 Î The following Keyboard Nationality selection is only valid for IBM AT compatible PCs Japanese Ì FJ8 Î 14 ...

Страница 21: ... handshaking hardware RTS CTS delay disabled rx timeout 9 9 sec ack nack disabled serial decode control disabled serial sleep control disabled DATA FORMAT code identifier enabled no field adjustment code length not transmitted no header terminator CR character replacement disabled RS232 Fujitsu DEFAULT SETTINGS 9600 baud no parity 8 data bits 1 stop bit no handshaking delay disabled rx timeout 2 s...

Страница 22: ...it control enabled decoding safety one read code 39 stitching enabled code 128 stitching enabled CODE SELECTION Enabled codes EAN 8 EAN 13 UPC A UPC E without ADD ON check digit transmitted no conversions autodiscriminate decoding safety 15 reads Interleaved 2 5 check digit control and transmission variable length code 6 99 characters Standard Code 39 no check digit control variable length code 4 ...

Страница 23: ...s below EAN 8 1234 5670 EAN 13 1 234567 000992 Code 39 Normal 1 7 1 6 2 Code 128 t e s t Interleaved 2 of 5 0 1 2 3 4 5 6 7 8 4 YOUR READER IS NOW READY TO READ BARCODES To change the defaults see the Presentation Scanners Software Configuration Manual 17 ...

Страница 24: ... reading diagram Max Resolution 0 12 mm 5 mils PCS Min 27 Datalogic Test Chart Scan Pattern 5 directions 20 lines Scan Rate 1500 scans seconds Environmental Features Operating Temperature 0 to 40 C 32 to 104 F Storage Temperature 20 to 70 C 4 to 158 F Humidity 0 to 90 RH non condensing Drop Resistance IEC 68 2 32 Test ED 1 2 m ESD Protection 16 KV Protection Class IP40 Mechanical Features Weight w...

Страница 25: ...CATCHER D531 SERIES READING DIAGRAM 0 5 10 15 20 25 15 10 5 0 5 10 15 Reading Zones 15 skew angle cm EAN13 M 1 0 33 mm 13 mils CODE 39 0 13 mm 5 mils CODE 39 0 21 mm 8 mils 19 ...

Страница 26: ...linking slow It blinks slower when the scanner is in Sleep mode Green Red blinking alternatively They turn on alternatively during serial configuration 1 only the Beeper Intensity command can modify these signals 2 the data entry good read tone is user configurable with all the Beeper commands in the Reading Parameter section WARRANTY Datalogic warranties this product against defects in workmanshi...

Страница 27: ...h allows device configuration using a PC It provides RS232 interface configuration as well as configuration barcode printing SERVICES SUPPORT Datalogic Services Warranty Extensions and Maintenance Agreements Authorised Repair Centres CONTACT US E mail form and listing of Datalogic Subsidiaries PATENTS This product is covered by one or more of the following patents U S patents 5 689 102 5 992 740 6...

Страница 28: ...ating to electromagnetic compatibility and product safety Basées sur la législation des Etats membres relative à la compatibilité électromagnétique et à la sécurité des produits Über die Annäherung der Gesetze der Mitgliedsstaaten in bezug auf elektromagnetische Verträglichkeit und Produktsicherheit entsprechen Basado en la aproximación de las leyes de los Países Miembros respecto a la compatibili...

Отзывы: