background image

-8- 

 

 

21) 

Select 

Communication>GSM

 tab. This page contains GSM-GPRS parameters. 

 

 

22) 

Enable GPRS Connection Enable parameter. This parameter enables all IP services 
(web client, SMTP) after saving to the controller. 
 

23) 

Enable SMS Enable parameter. 
 

24) 

Set other parameters in the box as required. 

 

25) 

If PIN code is used in your SIM card, then enter this code in 

GSM Sim Card Pin No

 field. 

Usually new SIM cards come without pin code. 

 

26) 

If 

Service Center No

 is not entered, then the controller will use the service center 

number recorded in the 

SIM card

. If entered, this number will be used. Usually this 

information is not necessary. 

 

27) 

APN ( access point name) information are necessary to connect to the GPRS network, 
and 

must 

be entered correctly. Otherwise connection to the GPRS network may not take 

place. If APN parameters are faulty, "

GPRS unusable/Bad APN

 " message will appear 

on the GSM Modem screen. These information is usually supplied by your GSM operator 
company. 

 

28) 

Telephone numbers for SMS sending are recorded in above fields. A maximum of 6 
numbers are available.  

 
 
 
 

Содержание D-700

Страница 1: ...lus D 500 D 700 Installation Guide Rainbow Plus D 500 D 700 Usage Guide Dynamic DNS Account Setting for D 500 D 700 RainbowScada Installation Guide RainbowScada User Guide The D 500 700 unit supports...

Страница 2: ...cable is 2 meters long The antenna is intended to be placed outside of the genset panel for the best signal reception Do not power up the D 500 700 unit before inserting the antenna and SIM Card The m...

Страница 3: ...lti slot class 10 8 GPRS mobile station class B Compliant to GSM phase 2 2 Class 4 2 W 850 900 MHz Class 1 1 W 1800 1900MHz Operating temp range 40 C to 85 C Data speed max 85 6 kbps downlink max 42 8...

Страница 4: ...Configuration mode 4 Read parameters from device 5 Select Communication Basic tab This page contains communication parameters 6 Engine Serial Number and Site Id information are used in the header of...

Страница 5: ...e used for restricting the external access to the embedded web server Leave these fields unchanged as above for unrestricted access Please consult Datakom for more details 12 Rainbow Server Adresses a...

Страница 6: ...ed If this parameter is enabled the D 500 700 device will send an e mail message each time the mains status is changed 17 E mail address 1 2 3 is the address to where e mail messages will be sent If e...

Страница 7: ...IP Confirmation address field should not be modified and must be left as per above settings 20 Ping Address may be set as required But above address is the most reliable one It is advised to leave it...

Страница 8: ...vice Center No is not entered then the controller will use the service center number recorded in the SIM card If entered this number will be used Usually this information is not necessary 27 APN acces...

Страница 9: ...9 When parameter editing is over click Write To Device button A progress bar will open 24 When the progress bar disappears the write process is done Progress bar Write To Device button...

Страница 10: ...low The program represents each unit as a coloured box on the map The map is downloaded from the internet The colour of the box will indicate the genset status for easy follow_up of the whole network...

Страница 11: ...roller into STOP mode Alarms are also cleared MODE AUTO Puts the controller into AUTO mode Alarms are also cleared Unit forced to AUTO Unit forced to STOP Alarms cleared GPRS disabled GPRS enabled The...

Страница 12: ...Sets remote controlled output 1 to active state OUT1 OFF Sets remote controlled output 1 to passive state OUT xx ON Sets remote controlled output xx to active state xx denotes any number between 1 an...

Страница 13: ...ains Change These messages are individually enabled or disabled by below program parameters Communication GSM SMS On IP Change Communication GSM SMS On Mains Change SMS messages are sent to all teleph...

Страница 14: ...0 700 is able to send SMS messages under all fault conditions SMS messages are sent to all telephone numbers programmed in below tab Communication GSM Message Numbers A sample message is below Alarm S...

Страница 15: ...his message is enabled or disabled by below program parameters Communication Options 2 E mail E mail on IP Change A sample message is below Last 10 event logs together with measured parameters are alw...

Страница 16: ...ge when any fault condition occurs A sample message is below Last 10 event logs together with measured parameters are always appended to the e mail message Alarm E mail Messages Alarm is indicated her...

Страница 17: ...ss is granted by the GSM system Data Receive and Transmit Indicators These indicators flash when data is received or transmitted through GPRS network Note that data counters are available in the next...

Страница 18: ...played IMEI Number This is the modem s unique identificaiton number Each GSM device has a different IMEI number Data Counters These counters increment with data received or transmitted through the eth...

Страница 19: ...received The D 500 700 device will execute the command given by the SMS message Sending SMS SMS message sending is in progress SMS preparing SMS message is about to be sent SMS Sent SMS message was s...

Страница 20: ...ived Send correct SMS command as explained in the SMS COMMANDS section of this document Connection error The dyndns service does not answer IP update request The D 500 700 device will reattempt IP upd...

Страница 21: ...may occur momentarily GPRS unusable Bad APN GSM system rejects GPRS connection because of faulty APN parameters Check end reenter correct APN parameters using the RainbowPlus program Communication GS...

Страница 22: ...twork GSM network is not available GSM operator indication disappears No GSM signal in current location Check antenna and antenna connections Relocate the antenna to a better reception place Try other...

Страница 23: ...modem returns a command xx denotes command step and C describes return type C B Bad response C E Error These messages are not critical and does not affect operation They are for debugging purposes onl...

Отзывы: