Manual Datafox KYO Inloc
page 43
date: 16.12.2020 Version: 04.03.15.XX
5.6.
Connecting of the box
5.6.1. Pin assignment of the box
The KYO Inloc Terminal has 8 module places for extensions.
View example with different modules (all modules are an option to order):
View on the right:
View on the left:
Number
Modul
PIN
description
Modulplace 1
1
1
ground
2
A RS 485 for access reader (
AC-Bus ID 1
)
3
B RS 485 for access reader (
AC-Bus ID 1
)
4
+ 12 V
Modulplace 2
2
1
common for pin 1 and 2
2
normally open; NO
3
normally closed; NC
4
digital input 1
+
5
digital input 1 ground
Modulplace 3
3
1
ground
2
A RS 485 for access reader (
AC-Bus ID 2
)
3
B RS 485 for access reader (
AC-Bus ID 2
)
4
+ 12 V
Modulplace 4
4
1
ground
2
A RS 485 main communication to a PC
3
B RS 485 main communication to a PC
4
not connect
Description of the different modules ZK-Box V4
M1
GPRS
M3
ZK
HK
DC 24V
- +
M7
LAN
M8
M3
M1
D
G
N
D
D
I
N
1
Relay
M2
485
-A
485
-B
1
2
V
G
N
D
485
-A
485
-B
1
2
V
G
N
D
ZK
485
-A
485
-B
1
2
V
G
N
D
M4
M5
M6
D
G
N
D
D
I
N
1
Relay
D
G
N
D
D
I
N
1
Relay
485
-A
485
-B
HK
SIM
View on the front:
- ON
power on
- Communication active
- Service / Error
- Akku low / flashing 1:1 = charge
- Memory active
- Button, no function
-Button, no function
- USB Micro
24V
- +
Содержание KYO Inloc
Страница 1: ...Manual Datafox KYO Inloc Flexible data collection with method ...
Страница 9: ......
Страница 13: ......
Страница 23: ......
Страница 46: ...Manual Datafox KYO Inloc page 39 date 16 12 2020 Version 04 03 15 XX Cklick on Switch to BIOS mode ...
Страница 109: ...Manual Datafox KYO Inloc page 102 date 16 12 2020 Version 04 03 15 XX 5 7 9 7 Pre checked online processing graph ...