An RS-485 repeater is necessary to extend the length of  an  RS-485
network,  or  connect  more  than  32  RS-485  devices  on  an  RS-485
network.

The SCM9B-D192 repeater contains a seven-pin screw  terminal  plug.
The pin designations are located on the label of each module. The screw
terminals will accept up to #14 gauge wire (AWG). This connector is used
for +5.0Vdc regulated power supply input and both pairs of RS-485 data
lines. The isolated RS-485 input data lines are clearly marked and their
ground reference is isolated by up to 500VRMS from the power supply
ground. The isolated RS-485 input data lines should be attached to the
end of an existing  RS-485  network.  The  serial  data  received  on  the
isolated RS-485 input data lines will be re-amplified and retransmitted on
the RS-485 OUT data lines.
.

Figure 1 Connections for SCM9B-D192.

BAUD RATE
The  SCM9B-D192  contains  a  10-position  DIP  switch  located  on  the
bottom  of  each  unit.  The  DIP  switch  is  used  to  select  the  correct
communications baud rate and must be set to the same value  as  the
devices connected to the RS-485 data lines. Each position on the DIP
switch is labeled from 1 to 10. Switch position 1 selects 300 baud. Switch
positions  2  thru  9  select  standard  baud  rates  from  600  to  57.6K
respectively. Switch position10 selects 115.2K baud rate. Only one baud
rate  switch  may  be  turned  on  (up  position)  at  one  time  for  proper
operation.

RS-485 TERMINATIONS
The proper termination techniques for any RS-485 system require two
biasing resistors and two termination resistors. The 1k

 biasing resistors

are connected from the DATA line to +5Vdc and from the DATA* line to

RS-485
Output

RS-485
Input

Содержание SCM9B-D192 Series

Страница 1: ... been carefully checked and is believed to be accurate however no responsibility is assumed for possible inaccuracies or omissions Applications information in this manual is intended as suggestions for possible use of the products and not as explicit performance in a specific application Specifications may be subject to change without notice ...

Страница 2: ...TAFORTH assumes no liability expressed or implied beyond its obligation to replace any component involved Such warranty is in lieu of all other warranties expressed or implied RETURNS When returning products for any reason contact the factory and request a Return Authorization Number and shipping instructions Write the Return Authorization Number on the outside of the shipping box DATAFORTH strong...

Страница 3: ...ths up to 4 000 feet and baud rates up to 115K baud using one twisted pair of wires The SCM9B D192 is an RS 485 repeater Repeaters are required to extend communications bus lengths or allow more than 32 RS 485 devices to be connected to a communications bus A repeater simply re amplifies or boosts existing RS 485 signals transmitted over long distances The SCM9B D192 is isolated between input and ...

Страница 4: ...ative humidity 0 95 noncondensing Warranty 3 years on workmanship and materials Power Specifications Power requirements Regulated 5Vdc Power consumption 1 0W Max RS 485 driver on MECHANICALS AND DIMENSIONS Case ABS case with screw terminal barrier plug supplied RS 485 Connectors Phoenix screw terminal barrier plug supplied Replace with Phoenix MSTB 2 5 4 ST 5 08 or equivalent Warranty 3 years on w...

Страница 5: ...nput data lines will be re amplified and retransmitted on the RS 485 OUT data lines Figure 1 Connections for SCM9B D192 BAUD RATE The SCM9B D192 contains a 10 position DIP switch located on the bottom of each unit The DIP switch is used to select the correct communications baud rate and must be set to the same value as the devices connected to the RS 485 data lines Each position on the DIP switch ...

Страница 6: ...interface any equipment on an RS 485 network These resistors are jumper selectable making it easier to interface the SCM9B D192 to other pieces of equipment that may or may not contain the biasing and or termination resistors RS 485 TERMINATION BIASING SETTINGS Proper termination and biasing of any RS 485 based system can be performed by properly enabling the correct resistors inside each SCM9B D1...

Страница 7: ...each row of pins The jumper designators are 1K 220 and 1K To enable any resistor place a jumper over the pins next to the required designator The factory switch and jumper settings are outlined below SCM9B D192 Baud Rate 300 baud switch up RS 485 J3 Biasing Resistors 1K 1K jumpers installed Termination Resistor 220 jumper installed Isolated RS 485 J2 Biasing Resistors 1K 1K jumpers installed Termi...

Отзывы: