![DataDirect Networks StorageScaler 2460 Скачать руководство пользователя страница 32](http://html.mh-extra.com/html/datadirect-networks/storagescaler-2460/storagescaler-2460_installation-and-user-manual_511622032.webp)
Solving Problems
96-00290-001 Rev. A1
DataDirect Networks StorageScaler 2460 User Guide | 26
Removing a Disk Drive or Blank Carrier
1.
Press the release button on the disk drive carrier to release the lever
(Figure 30)
.
Release Button
Figure 30. Release Button on Drive Carrier
2.
Gently pull open the lever
(Figure 31)
.
Figure 31. Drive Carrier with Lever Open
3.
If the enclosure is powered on, allow the disk drive to fully spin down (wait
approximately 30 seconds).
4.
Gently pull the disk drive out of the enclosure.
NOTE :
Do not remove the disk drive from its drive carrier. A disk drive removed
from its carrier is not covered by the hardware warranty.
5.
Immediately replace the disk drive or install a blank drive carrier to maintain correct
airflow and cooling. (See Section
2.4
.)
Removing a disk drive before it has fully spun down may result in
disk drive damage.
Warning
!
USO
RESTRITO