DM984 product family
CHAPTER 11. IPSAN CONFIGURATION
agement interface ip address. In order to upgrade, the firmware is loaded onto
the IPSAN’s MPU via the command:
copy onu-firmware <ipaddress> filename <filename>
Description of the used parameters:
Name
Format
Description
<ipaddress>
IPv4
ip address of the TFTP-Server
<filename>
Alphanumeric
Firmware image filename
Note:
In case the file is located in a folder at the TFTP-Server it is needed
to specify the path before the filename.
Example:
copy onu-firmware 10.0.0.1 filename firmware.bin
After this it is possible to update the firmware of the ONU by issuing the following
command:
copy onu-firmware filename <filename> gpon <unit>/<ponlink> onu
,
→
<id>
Description of the used parameters:
Name
Format
Description
<filename>
Alphanumeric
Firmware image filename
<unit>
Number (1-7)
Card slot of the plugged-in GPON card
<ponlink>
Number (1-8)
Ponlink the ONU is connected to
<id>
Number (1-128)
ID of the ONU to be added
Example:
copy onu-firmware filename firmware.bin gpon 7/1 onu 1
When checking the ONU status in the ONU menu it should indicate the status of
the software download as well as whether the update was successfully completed.
After the ONU is up again it should show the new software version in the same
view. Please refer to the section ONU status checking for further guidance on
how to check the ONU status.