DM984 product family
CHAPTER 10. FIRST STEPS WITH IPSAN
The following steps are done in the configuration menu. First it is necessary
to go into the menu of the management Ethernet.
interface mgmt-eth
Then an IP address is configured.
ip address <ip-address>/<mask>
Description of the used parameters:
Name
Format
Description
<ip-address>
IPv4 Address
IP address of the management Ethernet
<mask>
Number (4-30)
Subnet mask in bit
In some cases it might be necessary to configure static routes to ensure proper
connection to the IPSAN. For this purpose the following command must issued.
ip route <network-address>/<mask> <gateway>
Description of the used parameters:
Name
Format
Description
<ip-address>
IPv4 Network
IP address of the management Ethernet
<mask>
Number (4-30)
Subnet mask in bit
<gateway>
IPv4 Address
Default Gateway
Note:
In order to use this feature, fundamental knowledge about static IPv4
routing is necessary.
10.7 Setup of Management Access via SSH
The IPSAN has a dedicated management Ethernet interface which is used for
configuration purposes.
The following steps are done in the configuration menu. First it is necessary
to go into the menu of the management Ethernet.
interface mgmt-eth
Then an IP address is configured.
ip address <ip-address>/<mask>
Description of the used parameters:
DATACOM
204.4288.00
Содержание DM984-100B