Repeatability Test
The Repeatability Test confirms that multiple NEXT
measurements are essentially the same.
The Repeatability Test provides a means to verify the NEXT
measurement consistency of the LANcat as recommended by the
EIA/TIA TSB-67 Link Testing Standard. In the Repeatability Test,
NEXT tests are performed twice on the same pair combination and
the measured results compared. Differences should be less than
the magnitude of the LANcat NEXT measurement accuracy
specification.
RUNNING REPEATABILITY
1.
Connect one end of the cable under test to the LANcat and the
other end to the remote unit. If you are using a TwoWay
System, set the remote unit’s dial to Remote.
2.
Set dial to EXTENDED FUNCTIONS.
3.
Press the arrow keys to highlight REPEATABILITY.
4.
Press ENTER. Press ESC to abort the test.
(Press the arrow keys to select another cable test standard.)