Chapter 9
Calibration
Page 9-7
Performance Module Calibration
Each Performance Module used with the LANcat needs to be
calibrated in order to deliver maximum measurement accuracy.
LANcat automatically recognizes which type of Performance
Module is installed, and can store a set of calibration parameters
for each Performance Module type in non-volatile memory. It is
therefore possible for the LANcat to be calibrated to a number of
Performance Modules at the same time, provided that they are
different types. For example, the LANcat can be calibrated to both
a Modular Plug module and a Modular Jack module, thus allowing
change from one Performance Module to the other without need
for recalibration. If a Performance Module is replaced with another
of the same type, however, calibration of the new Performance
Module should be performed.
A Calibration Standard is available for convenient field calibration
of twisted pair Performance Modules. This Standard also enables
you at any time to perform a “confidence check” on the proper
operation of a Performance Module by repeating the calibration
procedure.
To calibrate a Performance Module:
NOTE
Press ESC at any time to cancel the calibration
procedure.
1.
Set the dial to CAL.
2.
Highlight PERFORMANCE MODULE in the Calibrate menu
using the arrow keys.
3.
Press CALIBRATE (F4) or ENTER. The CALIBRATE
PERFORMANCE MODULE screen will appear with the
displayed message “Connect To JACK 1”.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com