12
Firmware upgrade procedure
From time to time Datavideo may release new firmware to either add new features or to fix reported bugs in
the current RMC-180 firmware. Customers can update the firmware themselves if they wish or they can
contact their local dealer or reseller for assistance should they prefer this method.
This page describes the firmware update process and it should take
approximately 30 minutes total time
to complete
.
Once started
the update process should not be interrupted in any way
as this could result in a non-
responsive unit.
As well as a working RMC-180 you will need:
The latest Firmware Update. This can be obtained from your local Datavideo office.
A cable USB A to USB A no longer than 2m.
A Windows computer with a USB 2.0 port.
1. Power off RMC-180, and then connect the USB A cable from the
port on the RMC-180 rear
panel to chosen USB port on the computer.
2. Push and hold down the indicated buttons, all at same time.
3. Ask a colleague to switch on the RMC-180 power whilst still holding down these buttons.
4. The RMC-180 LCD will display as below.