background image

 

 

 

 

 

DT-ATSC-QAM-8V2 Manual 

Unpacking and Inspection 

Each unit is shipped from the factory tested. Ensure all items are removed from the container 

prior to discarding any packing material. 

Thoroughly inspect the unit for shipping damage with particular attention to connectors and 

controls. If there is any sign of damage to the unit or damaged or loose connectors contact your 

distributor right away. 

Installation 

System Installer must adhere to Article 820-40 of the NEC that provides guidelines for proper 

grounding and specifies that the cable ground shall be connected to the grounding system of 

the building, as close to the point of cable entry as possible. 

Introduction to DT-ATSC-QAM-8V2: ATSC-8VSB / QAM-B to QAM-B Trans-Modulator 

The DataTronix DT-ATSC-QAM-8V2 is a high quality 8VSB /Clear QAM to QAM Trans-

modulator. It was designed to allow system integrators to receive and process up to 8 individual 

8VSB (ATSC) / Clear QAM channels along with up to 56 sub channels, and easily convert these 

signals to produce a high-quality RF QAM distribution system. The DT-ATSC-QAM-8V2 is a 

highly flexible system allowing integrators to quickly receive, convert, and distribute high quality 

Digital QAM channels to their customers. 

Features 

  Accepts 8 RF inputs (ATSC-8VSB/QAM) 

  Allows for Up to 64 Output Programs 

  Allows User to “Cherry Pick” Desired Programs as Needed 

  Supports STD/HRC/IRC Formats 

  Supports Full Range of ATSC-8VSB/QAM Signals 

  Offers 8 Fully Independent RF QAM Outputs 

  Easy to Setup and Monitor with GUI 

  Front Panel LED Indicators  

  3 VCN Modes Supported 

  High Density 1RU Design 

 

System Parsing / Response Time: 

The initial System Parsing time will range from 4-6 minutes on average as the system identifies 

and populates the required parameters. As the user navigates the device's menu note that a 

small delay may occur in populating the data on the screen as the system is constantly 

performing system parsing and system house-keeping functions. 

 

Содержание DT-ATSC-IP-8V2

Страница 1: ...Manual 8 input ATSC 8VSB QAM B to QAM B Trans Modulator DT ATSC QAM 8V2 User Manual ...

Страница 2: ...e GUI Interface 6 Factory Default IP 192 168 1 9 6 System Setup via GUI Interface 6 Name admin Password Admin123 6 Overview Page 7 9 Ingest Setup 10 Streaming Setup 11 Streaming System Parameters 12 Customize the Streaming Setup View 13 RF Output Setup 14 Network Setup 15 Device IP Address Setup 15 Forgot IP Address 16 System Setup 16 Description 16 Time NTP Server Setup 17 Administration 17 Reboo...

Страница 3: ...rated power supply The use of any other power supply could cause damage and invalidate the manufacturer s warranty DO NOT connect the power cord to the device if the power cord is damaged DO NOT cut the power cord DO NOT plug the power cord into an AC outlet until all cables and connections to the device have been properly connected The device should be installed in an environment consistent with ...

Страница 4: ...eive and process up to 8 individual 8VSB ATSC Clear QAM channels along with up to 56 sub channels and easily convert these signals to produce a high quality RF QAM distribution system The DT ATSC QAM 8V2 is a highly flexible system allowing integrators to quickly receive convert and distribute high quality Digital QAM channels to their customers Features Accepts 8 RF inputs ATSC 8VSB QAM Allows fo...

Страница 5: ...ge 57 to 861 MHz Under STD Mode 8 Independent RF Frequencies Channels Bandwidth 6 MHz Output Level 45 dBmV Typical Output Impedance 75 ohm Level Adjustment 0 to 20 dB VCN Auto Major Minor Manual Major Minor Manual One Part Carrier Suppression 55 dB RF Output Return Loss 10 dB Typical Signal to Noise Ratio SNR 42 dB Typical MER 41 dB Minimum 44 dB Typical Alarms Monitoring Local Monitoring 8 x NIM ...

Страница 6: ... Cable directly to the Utility Port on the rear panel of the device or connect the Ethernet cable to an Ethernet switch Connect an Ethernet cable to Your PC Laptop 2 Modify Your PC Laptop IPV4 address to 192 168 1 11 3 Enter Default IP Address for DT ATSC QAM 8V2 into Your Web Browser Suggested browser Firefox or Chrome Factory Default IP 192 168 1 9 System Setup via GUI Interface After connecting...

Страница 7: ...ew Page provides an overall system status of the DT ATSC QAM 8V2 including RF Input Type Frequency SNR Signal Status and Programs Programs If you move your cursor to you will see the detailed information see figure below as example of the Programs ...

Страница 8: ...8 DT ATSC QAM 8V2 Manual Overview RF Output RF Outputs showing the number of sub streams programs ...

Страница 9: ...9 DT ATSC QAM 8V2 Manual Overview Fan This tab shows fan status and system uptime ...

Страница 10: ...ingest input 1 thru 8 Enable as required 3 Select Standard ATSC or QAM ATSC 8VSB QAM STD QAM HRC QAM IRC 4 Select Constellation For QAM select 64 QAM or 256 QAM as required 5 Select Frequency MHz Input ATSC 8VSB UHF CH 14 69 VHF CH 2 13 QAM CH 2 CH 135 57 MHz to 861 MHz 6 Save and Confirm to save all changes Note Leaving any ingest setup page without saving the set parameters will cause the device...

Страница 11: ... Name 1 16 Characters 5 Select VCN Mode VCN Mode 2 Part Auto Example 102 1 Set Automatically by the Device VCN Mode 2 Part Manual 102 2 Manual Entry by User VCN Mode 1 Part Manual 102 Manual Entry by User Note Only 1 VCN mode type can be selected 6 Modify Source ID as required Note If installing multiple DT ATSC QAM 8V2 units make sure not to duplicate source ID outputs 7 Select RF from 1 8 to ass...

Страница 12: ...SID Service ID Program ID Short Name From Content Provider Long Name From Content Provider Bit Rate Input Bit Rate Output SID Service ID Definable PMT PID Program Map Table PID Video PID Video Stream PID Audio PID Audio Stream PID Short Name Definable 1 7 Characters Long Name Definable 1 16 Characters VCN Mode Selectable Auto 2 Part Manual 2 Part Manual 1 Part VCN Definable When Using Manual VCN M...

Страница 13: ...iew The Streaming Setup parameters page is easily customizable for each system To customize the parameters shown 1 Select Select Columns tool 2 Add or remove parameter as needed by selecting or deselection 3 Close window after selecting deselecting parameters ...

Страница 14: ...ation 0 20dB 1dB Steps 9 Select constellation 64 QAM 256 QAM 10 Select interleaver change as required Default I 128 J 1 11 Save and Confirm all changes Note 1 Bitrate Mbps shown allows the integrator to quickly review assigned stream bitrate allocated and Capacity Note 2 Bitrate mapping may be required based on the Mbps of the streams programs in the RF Out Note 3 Use the Streaming Setup Page to m...

Страница 15: ...the IP address of the device 2 Modify hostname as required 3 Select DHCP or static IP 4 For Static IP select static IP and enter static IP address for device 5 Enter Subnet Mask 6 Enter Default Gateway 7 Enter DNS Server 1 address 8 Enter DNS Server 2 address if required 9 Save and Confirm all changes ...

Страница 16: ...e the reset button once the power LED stops flashing and become static green 4 Unit s IP address will revert back to default IP 192 168 1 9 5 Unit s login data will revert back to factory default Name admin Password Admin123 Note ONLY THE IP ADDRESS WILL REVERT BACK TO DEFAULT SETTING NO CHANGES WILL BE MADE TO THE CONFIGURATION System Setup Description Use the System Setup Page to designate locat...

Страница 17: ...ect time zone from the drop down tool 3 Enter NTP Server 1 2 addresses as required 4 Select synchronize system with PC clock as required 5 Select apply to apply all changes Administration Reboot Use the Reboot button to reboot the device No parameters will be changed Reset to Default Use the Reset to Default button to reset all parameters to original factory settings ...

Страница 18: ...setup Streaming Setup RF Out Setup Network Setup System Setup 4 Locate and Name file for future use Note The backup can be imported to assist in setting up new or multiple devices onsite Remember to Save and backup any and all changes Restore 1 Select administration tab 2 Browse the required file to be imported 3 Select Upload to import the selected file into the device Note Do not power off the u...

Страница 19: ...t administration tab 2 Select firmware upgrade tab 3 Browse to locate the required image file to be uploaded 4 Select Upload to import the selected file into the device Note Do not power off the unit while importing Change Password Use the password section to change or modify the device s password as desired ...

Страница 20: ... device that performs Network Address Translation Anyone can us private addresses and they are not required to seek permission to use them Again networks using private IP addresses cannot communicate directly with the internet There are three blocks of addresses that are set aside by IANA for use in private internets and are not publicly routable on the global internet Private Class A Range 10 0 0...

Страница 21: ...or replacing the hardware This warranty is contingent upon proper use of the hardware by Original Purchaser and does not cover if damage is due to Acts of God including fire flood earthquake storm hurricane or other natural disaster accident unusual physical electrical or electromechanical stress modifications neglect misuse operation with media not approved by the Company tampering with or alteri...

Страница 22: ...anties whether oral or written The agents employees distributors and dealers of the Company are not authorized to make modification to this warranty or additional warranties binding on the Company Accordingly additional statements such as dealer advertising or presentations whether oral or written do not constitute warranties by the Company and should not be relied upon This warranty gives you spe...

Отзывы: