Maintenance ■ Pick and Place Probe
- 108 -
Data I/O ■ 096-0465-001C
Reinstall in reverse order being careful not to damage the O-Ring on the
bowl.
Reconnect the shop air supply line.
Figure 64:
Replacing the Air Filter/Regulator.
Vacuum Generator Filters and Silencers
These procedures cover removing and cleaning or replacing vacuum
generator parts for vacuum generators on PSV5000 head.
A clogged or dirty vacuum filter or silencer can cause dropped devices
and placement problems at the PNP head.
R
EQUIREMENTS
• metric hex key set
• flat screwdriver
• small Phillips screwdriver
V
ACUUM
G
ENERATOR
F
ILTERS
1.
Finish a job if one is running.
2.
Use the Gantry window to move the PNP head to an accessible
location such as the Tool position.
3.
Properly shut OFF the PSV5000 System. See
Shutting Down the
PSV5000 System on page