DASS 3.0i LV (DSP-123i-ODS)
User manual
Copyright © DASS Tech Co., Ltd
- 60 -
8.3. Efficiency,Protection and Communication
Technical Data
DASS 3.0i LV (DSP-123i-ODS)
Max.Efficiency
97.7%
Euro Efficiency
97.2%
MPPT Efficiency
>99.9%
Self-consumption at night
<1W
Safety protection
Anti islanding,RCMU,Ground fault monitoring
Certification
AS 4777, VDE V 124-100,VDE V 0126-1-1,VDE-AR-N 4105,EN
50438,G83/2,C10/11,RD1699
Protective class
Class I
External environment
pollution degree
Degree 3
Overvoltage category
PV:OVC II, AC mains:OVC III
Max inverter Back-feed
current to the array
0A
Output short circuit current
to the array
200A/1us
Output inrush current and
duration
0.8A/2us