27
Location 300-303: Programming the Communicator Code for Zone 12
Locations 300-303 are used to control the communicator code for zone 12. Zone 12 is automatically enabled and when
contact I.D is selected the default report is event "130 - Burglary" with point "12" when in alarm. Refer to appendix 1 if a
different event type is required. The defaults are "3:1:2:5" with telephone number 1 and the event log enabled.
Location 304-307: Programming the Communicator Code for Zone 13
Locations 304-307 are used to control the communicator code for zone 13. Zone 13 is automatically enabled and when
contact I.D is selected the default report is event "130 - Burglary" with point "13" when in alarm. Refer to appendix 1 if a
different event type is required. The defaults are "3:1:3:5" with telephone number 1 and the event log enabled.
Location 308-311: Programming the Communicator Code for Zone 14
Locations 308-311 are used to control the communicator code for zone 14. Zone 14 is automatically enabled and when
contact I.D is selected the default report is event "130 - Burglary" with point "14" when in alarm. Refer to appendix 1 ff a
different event type is required. The defaults are "3:1:4:5"with telephone number 1 and the event log enabled.
Location 312-315: Programming the Communicator Code for Zone 15
Locations 312-315 are used to control the communicator code for zone 15. Zone 15 is automatically enabled and when
contact I.D is selected the default report is event "130 - Burglary" with point "15" when in alarm. Refer to appendix 1 if a
different event type is required. The defaults are "3:1:5:5" with telephone number 1 and the event log enabled.
Location 316-319: Programming the Communicator Code for Zone 16
Locations 316-319 are used to control the communicator code for zone 16. Zone 16 is automatically enabled and when
contact I.D is selected the default report is event "130 - Burglary" with point "16" when in alarm. Refer to appendix 1 if a
different event type is required. The defaults are "3:1:6:5" with telephone number 1 and the event log enabled.
Location 320-322: Communicator Code For Duress Code
The DL-300E has the ability to report a duress code when the system is armed or disarmed with user code number 15 and
a duress communicator code is enabled in Data 1. When contact I.D is selected, program Data 1 with the required event
code from appendix 1 to enable this report event. Program a "10" in Data 1 to report event "121 - Duress". The Open/Close
report will accompany the Duress report complete with the user number to indicate that an Open or Close was preformed
under Duress. No restore code is reported for this event. If Data 1 is a "0", the duress capability is disabled and user code
number 15 can only be used as a standard arm/disarm code. The defaults are "0:0:0:5" with telephone number 1 and the
event log enabled.
Location 324-326: Code Pad Auxiliary 1 ([1] & !31) Communicator Codes
The DL-300E has the ability to report an auxiliary 1 code and activate the priority (fire) siren each time the [1 ] and [3] keys
are pressed simultaneously on the Code Pad. The desired reporting code must be programmed into these locations. When
contact I.D is selected, program Data 1 with the required event code from appendix 1 to enable this report event. Program
a "1" in Data 1 to report event "110 -Fire". If activated, the siren can be silenced by entering any arm/disarm code. No
restore code is reported for this event. If Data 1 is "0", the Auxiliary 1 double caprice is disabled. The defaults are "0:0:0:5"
with telephone number 1 and the event log enabled.