background image

RF EMISSIONS

 The high frequency resonant converters in the DX series amplifiers have been designed to have 

very  low  radio  frequency  (RF)  emissions;  however  even  these  low  level  emissions  can  cause 

interference with other equipment.

In  order  for  this  to  be  minimised,  the  amplifier  should  be  mounted  in  a  metal  rack  enclosure, 

which  should  have  a  separate  (technical)  Earth.  Alternatively  a  separate  earth  should  be 

attached to the amplifier at the rear rack mounting bracket.

DYNAMIC AMPLIFIER PERFORMANCE MEASUREMENTS

The  DX  series  is  the  very  latest  example  of  a  'dynamic  amplifier'.  This  new  'breed'  of  power 

amplifiers  provide  very  high  peak  power  levels  in  a  much  smaller,  and  lighter,  package  than 

previously possible with conventional amplifiers.

  They  are  designed  specifically  for  today's  high  power  audio  installations,  which  use  multiple 

speakers with electronic crossovers or speaker controllers. These systems can handle very high 

transient  signals  that  far  exceed  their  RMS  power  rating.  The  DX  series  amplifiers  have  been 

designed to match this requirement and can deliver huge levels of power for short durations.

In  order  to  protect  themselves  and  the  loudspeakers  that  they  are  driving,  continuous  signals 

such as sine waves, are automatically detected and reduced (ramped down) to a safe level.

When trying to measure the power output however, continuous signals will give totally incorrect 

results.  A  dynamic  signal,  such  as  a  tone  burst,  should  be  used  and  the  levels  measured  by 

monitoring  the  waveform  on  an  oscilloscope.  The  power  envelope  can  then  be  accurately 

measured.

Our power output figures are measured using signals with known Crest Factors and are quoted 

at the rear of this manual on page 43 and on our website.

Please refer to the technical area of our website for further information.

INITIAL SET-UP AND SWITCHING ON

Please read all documentation before operating your equipment and retain all documentation 

for future reference.

Do not spill water or other liquids into or on the unit and do not operate the unit while standing 

in liquid.

Do  not  block  fan  intake  or  rear  ventilation  outlets  or  operate  the  unit  in  an  environment  that 

could impede the free flow of air around the unit.

If  the  unit  is  used  in  an  extremely  dusty  or  smoky  environment,  it  should  be  cleaned  of  any 

collected debris at regular intervals. Please also see the notes regarding maintenance on page 
10. It  is  important  that  the  power  output  of  your  amplifier  is  matched  to  the  power  handling

capacity of your loudspeaker. If not, damage to the loudspeaker could occur.

Switching On…

At 'switch-on' the protection circuit will initially activate whilst the circuits stabilise, indicated by 

the red A/P LED illuminating, in addition to various other LEDs. After a few seconds the red A/P 

LED  will  extinguish  indicating  a  satisfactory  working  condition.  Other  LEDs  may  remain 

illuminated  depending  upon  rear  panel  switch  settings  and  input  connections.  If  the  A/P  LED 

does not extinguish after 5 seconds the unit may be faulty or some external connections may be 

incorrect or inappropriate. If this occurs you should power down the unit and remove all external 

connections  (except  for  the  mains  power  supply)  and  repeat  the  power  up  sequence.  If  the 

problem persists please contact us.

E11EVEN SOUND \ 

DX 

User’s Manual

8

Содержание SOUND E11EVEN DX Series

Страница 1: ...User s Manual DX series Amplifiers Before operating the device please read the Safety precautions section of this manual www 11sound com Deliver the Nightclub Sound Experience we all Deserve ...

Страница 2: ...ROL SOFTWARE 3 4 5 6 7 8 9 18 PRESET RECALL CREATING A NEW PRESET DEVICE PARAMETERS ROUTING INPUT EQ OUTPUT EQ DYNAMIC EQ DEQ GRAPHIC EQ GEQ SAVING THE FILE AND GOING ONLINE 10 11 13 14 16 18 20 21 LIMITERS COMPRESSORS LOAD OUTPUT CHANNEL SETTINGS LOCK DEVICE 22 23 24 25 26 28 E11EVEN SOUND DX User s Manual ...

Страница 3: ...SIDERATIONS INSTALLATION MECHANICAL CONSIDERATIONS RF EMISSIONS DYNAMIC AMPLIFIER PERFORMANCE MEASUREMENTS INITIAL SET UP AND SWITCHING ON 6 7 8 8 8 FRONT PANEL REAR PANEL 9 10 MAINTENANCE LINE INPUTS AND OUTPUTS SPEAKER OUTPUTS BRIDGED MONO OPERATION 10 11 11 12 SPECIFICATIONS 13 E11EVEN SOUND DX User s Manual ...

Страница 4: ...ources such as radiators heat registers stoves or other apparatus that produce heat 9 Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has two blades and a third grounding prong The wide blade or the third prong are provided for your safety If the provided plug does not fit into your outlet ...

Страница 5: ...plier Declares that The following products DX 80 DX100 Are manufactured in accordance with EMC Directive 2014 30 EU in compliance with the following technical regulations EN55103 1 2009 EN55103 2 2009 and in accordance with the Low Voltage Directive 2006 95 EC in compiance with technical regulations EN IEC60065 2014 E11EVEN SOUND DX User s Manual ...

Страница 6: ...ct use of the product All warranty repairs must be exclusively undertaken by the factory or any of its authorised service centers To claim a warranty repair do not open or intend to repair the product All the details related to the warranty such as extended warranties can be found in the SUPPORT section on our website www 11sound com E11EVEN SOUND DX User s Manual ...

Страница 7: ...ultiple channels of audio from a network With a range of power levels available in the DX series the amplifiers can be networked to a single DXi model creating a powerful efficient system that s easy to expand and adapt for use in live install and everything in between INSTALLATION ELECTRICAL CONSIDERATIONS The amplifier has been manufactured to comply with your local power supply requirements but...

Страница 8: ...ION cont d INSTALLATION MECHANICAL CONSIDERATIONS To ensure that this equipment performs to specification it should be mounted in a suitable rack or enclosure as described below Like all high power amplifiers it should be kept away from other equipment which is sensitive to magnetic fields Also this amplifier may suffer a substantial reduction in performance if it is subjected to or mounted close ...

Страница 9: ...n then be accurately measured Our power output figures are measured using signals with known Crest Factors and are quoted at the rear of this manual on page 43 and on our website Please refer to the technical area of our website for further information INITIAL SET UP AND SWITCHING ON Please read all documentation before operating your equipment and retain all documentation for future reference Do ...

Страница 10: ...cuit can affect all channels or a channel pair depending on the type of fault This is indicated by the combination of Protection LED illuminating and a corresponding message on the LCD In this way it is possible for two channels a channel pair to remain functioning even though a fault has caused the other channel pair to mute A channel pair would be 1 2 or 3 4 Temperature related faults will reset...

Страница 11: ...h on the far left of the panel beside channel A s input XLR 6 Link switch Press this switch to link the input of the channel to its immediate left Multiple channels may be linked using these switches so for example to link all outputs to input A press all three switches IN and use input A only The front panel attenuators will still operate independently when channels are linked Linking is disabled...

Страница 12: ...ommendations Pin 1 is connected directly to the chassis mains earth If ground loops mains hum are encountered remove the screen connection from the other end of the cable and leave it open circuit If problems persist consult your dealer supplier DO NOT TAMPER WITH OR ALTER ANY GROUND EARTH CONNECTIONS INSIDE THE AMPLIFIER For bridged operation input should be made to channel A or C only and the ch...

Страница 13: ...ent capacity of the speaker cables will need to be increased above the values quoted here Do not connect the inputs outputs to any other voltage source such as a battery mains source or power supply regardless of whether the amplifier is turned on or off Do not run the output of any amplifier channel back into another channel s input and do not parallel or series connect an amplifier output with a...

Страница 14: ...hippinq 11 6 12 3 Additional Specifications Parameter Units DX 80 DX 100 Input lmpedance Active Balanced Ohms 20k 20k Input CMRR dB 60 60 Dampinq Factor 1kHz 8 ohms 400 400 Sianal Limiters Present Yes Yes Pr otection Present Short Circuit DC Outout Temoerature Yes Yes Mains ln rush Control Present Yes Yes Output Power per channel 8 Ohms Watts Continuous music Crest Factor of 2 8 ar 9dB 975 1360 Co...

Страница 15: ...sumption and Thermal Emissions DX 100 Mains Load Current Draw V IR Al Thermal Emissio ns W No Sig l Light Average Heavy No Sig l Light Average Heavy 240 8 2 1 3 2 5 1 9 6 504 533 582 701 240 4 2 1 4 1 7 5 15 7 504 557 647 863 240 2 2 1 4 6 8 9 19 1 504 570 682 953 120 8 4 7 6 9 10 6 19 6 560 589 638 757 120 4 4 7 8 7 15 5 31 9 560 613 703 919 120 2 4 7 9 7 18 2 38 7 560 626 738 1009 No Sig I Quies...

Страница 16: ...www 11sound com ...

Отзывы: