background image

6

INTRODUCTION

Thank you for choosing a DX series amplifier for your application.

Please  spend  a  little  time  reading  through  this  manual,  so  that  you  obtain  the  best 

possible performance from the unit and become familiar with its operating requirements.

All  DAS  Audio  Group  products  are  carefully  designed  and  engineered  for  cutting-edge 

performance and world-class reliability. If you would like further information about this or 

any other DAS Audio product, please contact us.

We wish you many years of service from this amplifier and look forward to hearing from 

you in the near future.

The  DX  amplifier  series  has  been  designed  to  combine  incredible  audio  power  and 

performance with ultra-flexible connectivity for both remote control and audio. Exemplary 

audio  processing  is  assured  through  the  use  of  an  external  DAS's  DSP,  or  of  the  DSP 

platform in the DXi models, and power amplifier capabilities are taken care of with high 

efficiency output stages and a generous power supply.

All  units.  DX-100  and  DX-80,  can  include  optional  Dante  networked  audio.

 

Accepting  analogue,  or  optional  Dante  networked  audio,  this  extra  connectivity  means 

that  the  DX  models  can  also  be  used  in  installation  systems  which  already  have  a 

centralized DSP core but require the flexibility of being able to pick up multiple channels 

of audio from a network.

 With a range of power levels available in the DX series, the amplifiers can be networked to 

a single DXi model, creating a powerful, efficient system that's easy to expand and adapt 

for use in live, install and everything in between.

INSTALLATION: ELECTRICAL CONSIDERATIONS

The  amplifier  has  been  manufactured  to  comply  with  your  local  power  supply 

requirements,  but  before  connecting  the  unit  to  the  supply,  ensure  that  the  voltage 

(printed on the rear panel) is correct.

The amplifier is fitted with either a 100/120V or 220/240V tapped transformer according to 

customer requirements.

Make  sure  power  outlets  conform  to  the  power  requirements  listed  on  the  back  of  the 

unit.  Damage  caused  by  connecting  to  improper  AC  voltage  is  not  covered  by  the 

warranty.

Safety Warning

Apparatus with CLASS I construction shall be connected to a MAINS socket outlet with a 

protective earthing connection.

Where  a  MAINS  plug  or  appliance  coupler  is  used  as  the  disconnect  device,  it  should 

remain readily operable.

Where the amplifier is mounted in a rack and permanently connected to the mains, then 

the  rack  should  be  installed  with  a  readily  accessible  connector  or  an  ALL  POLE  circuit 

breaker with 3mm breaking distances.

This  unit  is  fitted  with  a  3-wire  power  connector.  For  safety  reasons,  THE  EARTH  LEAD 

SHOULD  NOT  BE  DISCONNECTED  IN  ANY  CIRCUMSTANCE.  If  ground  loops  are 

encountered consult the section on Line Inputs and Outputs on page 11.

E11EVEN SOUND \ 

DX 

User’s Manual

Содержание SOUND E11EVEN DX Series

Страница 1: ...User s Manual DX series Amplifiers Before operating the device please read the Safety precautions section of this manual www 11sound com Deliver the Nightclub Sound Experience we all Deserve ...

Страница 2: ...ROL SOFTWARE 3 4 5 6 7 8 9 18 PRESET RECALL CREATING A NEW PRESET DEVICE PARAMETERS ROUTING INPUT EQ OUTPUT EQ DYNAMIC EQ DEQ GRAPHIC EQ GEQ SAVING THE FILE AND GOING ONLINE 10 11 13 14 16 18 20 21 LIMITERS COMPRESSORS LOAD OUTPUT CHANNEL SETTINGS LOCK DEVICE 22 23 24 25 26 28 E11EVEN SOUND DX User s Manual ...

Страница 3: ...SIDERATIONS INSTALLATION MECHANICAL CONSIDERATIONS RF EMISSIONS DYNAMIC AMPLIFIER PERFORMANCE MEASUREMENTS INITIAL SET UP AND SWITCHING ON 6 7 8 8 8 FRONT PANEL REAR PANEL 9 10 MAINTENANCE LINE INPUTS AND OUTPUTS SPEAKER OUTPUTS BRIDGED MONO OPERATION 10 11 11 12 SPECIFICATIONS 13 E11EVEN SOUND DX User s Manual ...

Страница 4: ...ources such as radiators heat registers stoves or other apparatus that produce heat 9 Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has two blades and a third grounding prong The wide blade or the third prong are provided for your safety If the provided plug does not fit into your outlet ...

Страница 5: ...plier Declares that The following products DX 80 DX100 Are manufactured in accordance with EMC Directive 2014 30 EU in compliance with the following technical regulations EN55103 1 2009 EN55103 2 2009 and in accordance with the Low Voltage Directive 2006 95 EC in compiance with technical regulations EN IEC60065 2014 E11EVEN SOUND DX User s Manual ...

Страница 6: ...ct use of the product All warranty repairs must be exclusively undertaken by the factory or any of its authorised service centers To claim a warranty repair do not open or intend to repair the product All the details related to the warranty such as extended warranties can be found in the SUPPORT section on our website www 11sound com E11EVEN SOUND DX User s Manual ...

Страница 7: ...ultiple channels of audio from a network With a range of power levels available in the DX series the amplifiers can be networked to a single DXi model creating a powerful efficient system that s easy to expand and adapt for use in live install and everything in between INSTALLATION ELECTRICAL CONSIDERATIONS The amplifier has been manufactured to comply with your local power supply requirements but...

Страница 8: ...ION cont d INSTALLATION MECHANICAL CONSIDERATIONS To ensure that this equipment performs to specification it should be mounted in a suitable rack or enclosure as described below Like all high power amplifiers it should be kept away from other equipment which is sensitive to magnetic fields Also this amplifier may suffer a substantial reduction in performance if it is subjected to or mounted close ...

Страница 9: ...n then be accurately measured Our power output figures are measured using signals with known Crest Factors and are quoted at the rear of this manual on page 43 and on our website Please refer to the technical area of our website for further information INITIAL SET UP AND SWITCHING ON Please read all documentation before operating your equipment and retain all documentation for future reference Do ...

Страница 10: ...cuit can affect all channels or a channel pair depending on the type of fault This is indicated by the combination of Protection LED illuminating and a corresponding message on the LCD In this way it is possible for two channels a channel pair to remain functioning even though a fault has caused the other channel pair to mute A channel pair would be 1 2 or 3 4 Temperature related faults will reset...

Страница 11: ...h on the far left of the panel beside channel A s input XLR 6 Link switch Press this switch to link the input of the channel to its immediate left Multiple channels may be linked using these switches so for example to link all outputs to input A press all three switches IN and use input A only The front panel attenuators will still operate independently when channels are linked Linking is disabled...

Страница 12: ...ommendations Pin 1 is connected directly to the chassis mains earth If ground loops mains hum are encountered remove the screen connection from the other end of the cable and leave it open circuit If problems persist consult your dealer supplier DO NOT TAMPER WITH OR ALTER ANY GROUND EARTH CONNECTIONS INSIDE THE AMPLIFIER For bridged operation input should be made to channel A or C only and the ch...

Страница 13: ...ent capacity of the speaker cables will need to be increased above the values quoted here Do not connect the inputs outputs to any other voltage source such as a battery mains source or power supply regardless of whether the amplifier is turned on or off Do not run the output of any amplifier channel back into another channel s input and do not parallel or series connect an amplifier output with a...

Страница 14: ...hippinq 11 6 12 3 Additional Specifications Parameter Units DX 80 DX 100 Input lmpedance Active Balanced Ohms 20k 20k Input CMRR dB 60 60 Dampinq Factor 1kHz 8 ohms 400 400 Sianal Limiters Present Yes Yes Pr otection Present Short Circuit DC Outout Temoerature Yes Yes Mains ln rush Control Present Yes Yes Output Power per channel 8 Ohms Watts Continuous music Crest Factor of 2 8 ar 9dB 975 1360 Co...

Страница 15: ...sumption and Thermal Emissions DX 100 Mains Load Current Draw V IR Al Thermal Emissio ns W No Sig l Light Average Heavy No Sig l Light Average Heavy 240 8 2 1 3 2 5 1 9 6 504 533 582 701 240 4 2 1 4 1 7 5 15 7 504 557 647 863 240 2 2 1 4 6 8 9 19 1 504 570 682 953 120 8 4 7 6 9 10 6 19 6 560 589 638 757 120 4 4 7 8 7 15 5 31 9 560 613 703 919 120 2 4 7 9 7 18 2 38 7 560 626 738 1009 No Sig I Quies...

Страница 16: ...www 11sound com ...