background image

 

Page 16 of 22 

5. Maintenance 

The proposed maintenance is only a suggestion. Depending on the use of the product 

and the operating environment, this may need to be revised more often. 

 

DO NOT ATTEMPT ANY FIXES BEFORE CONSULTING DARAY. 

 

If you cannot resolve a problem then please contact our helpline on 0800 878 9864 

or email [email protected] 

 

5.1 Maintenance schedule 

 

Weekly checks 

should include:- 

Range of movement testing, it should be light and easy to move 
throughout the range 
No visible signs of excessive wear. 

Six monthly 

checks to 

include:- 

Check all electrical connections are sound and that there is no 
visible cable wear. 

All fixings to be checked and be of sound construction. 

 
 

5.2 Safety Precautions 

 

 

For all cleaning work, power off the equipment and where possible unplug 
the mains socket, only minimal cleaning fluids should be used. 

 

Please do not look directly into the light source when illuminated. 

 

If the equipment is dented or scratched this should not impact the usability 
of our lights however we advise that if the BioProtect® coating is damaged 
and the metal casing underneath is visible, please do not attempt to ‘paint’ 
over it as this will impact upon the effectiveness of the coating, simply use 
an alcohol based cleaning spray when cleaning and pay special attention to 
the cut. 
 
If there is damage to the power cable or if exposed wire is visible  

DO NOT USE

 

 

 

Содержание X200

Страница 1: ...X200 LED Examination Light Operating Installation Manual QAM X200 0519 12...

Страница 2: ...Page 1 of 22...

Страница 3: ...4 1 1 Considerations 9 4 1 2 Placement and Installation 10 4 2 Rail mounted version X200LR 12 4 3 Desk mounted versions X200LD X200LDS X200LFDM 12 4 4 Mobile version X200LM 13 4 5 Optional battery ba...

Страница 4: ...n DARAY s BioProtect coating an antimicrobial protection against infection causing bacteria such as MRSA The light comprises 3 parts light head and flexible arm system power supply module and the moun...

Страница 5: ...ured in Great Britain by Daray Ltd Edison House Robian Way Swadlincote Derbyshire DE11 9DH 1 1 Supported Lights The Following Models are supported in this Manual X200LW X200 LED Wall Mounted Light X20...

Страница 6: ...500 Colour Rendering Index CRI 95 Colour Rendering R9 88 Light Field Diameter D50 0 5m 120mm 0 75m 135mm 1 0m 180mm Light Field Diameter D10 0 5m 230mm 0 75m 325mm 1 0m 460mm Number of LED s 3 Power...

Страница 7: ...8m 1 Desk Clamp Fixed Desk Mount Desk Stand 1 Wall bracket fixings 1 Light head and flexible arm 1 Thumb Screw for Wall Mount 1 Microfibre cleaning cloth 1 Microfibre cleaning cloth 1 User Manual 1 M...

Страница 8: ...Page 7 of 22 3 Operation 3 1 Range of Motion This is an image depicting the range of motion on the X200 light all versions...

Страница 9: ...and hold to adjust the intensity It takes approximately 4 seconds to switch between the highest and lowest settings Release the button when at a comfortable setting for the user Press once to power OF...

Страница 10: ...to the underside of the bracket dependent on couch height It may be necessary to adjust this height if there are specific medical procedures the light will be used for If in doubt consult the end use...

Страница 11: ...in mind the final position of the light head required to project its light patch where it will be needed We recommend 850 1100mm from the floor to the underside of the bracket dependent on couch heig...

Страница 12: ...light on See page 8 Check arm and head for smooth and correct movement Your new DARAY light is now ready for use To gain full support of our warranty please fill in our warranty web form or contact DA...

Страница 13: ...can be moved along the rail by slackening the clamp slightly and not sufficiently to allow the light to become detached from the rail 4 3 Desk mounted versions X200LD X200LDS X200LFDM X200LD includes...

Страница 14: ...g If not already fitted fit the castors to the base by knocking them sharply into their fixing sockets Insert the up stand into the castor base as shown below Do not use a metal hammer Once fitted the...

Страница 15: ...e into the black power supply attached to the base upstand The light can now be tested by connecting the DC jacks between the power supply and the light and applying power Press the switch on the head...

Страница 16: ...mobile version of this light please use the extension cable provided NOTE Charging time can take up to 8 hours depending on how depleted the battery is 2 If you need to use the light on battery power...

Страница 17: ...and that there is no visible cable wear All fixings to be checked and be of sound construction 5 2 Safety Precautions For all cleaning work power off the equipment and where possible unplug the mains...

Страница 18: ...our BioProtect antimicrobial coating on painted finishes This is designed to assist with infection control and is not a replacement for cleaning CAUTION Our products are NOT waterproof The equipment...

Страница 19: ...ight 5 4 2 Detaching Parts De construction of the lights should be done following a reverse order of the instructions in section 4 The X200 is a completely enclosed light and arm it should not be open...

Страница 20: ...e extension cable are fully connected For the mobile version ensure that the IEC is firmly pushed into the PSU Poor Light output Power Button Please check the variable intensity is not just set to its...

Страница 21: ...SPARE PARTS or TECHNICAL ISSUES phone DARAY S Service Delivery Team on 44 0 800 878 9864 Opening times 9am 5pm Monday to Thursday excluding bank holidays 9am 2 30pm on Friday Or email support daray co...

Страница 22: ...ges may be applicable OTHER Any situation which is not covered by any of the above We will always try to help but we cannot normally offer a refund For additional clarification please refer to our ter...

Страница 23: ...Daray s instructions Attachment of fittings and accessories not approved by Daray Repairs modifications carried out by service personnel not approved by Daray Damage caused by chemical corrosion from...

Страница 24: ...Page 23 of 22 Service Notes...

Страница 25: ...Page 24 of 22...

Страница 26: ...Page 25 of 22...

Страница 27: ...Page 26 of 22...

Страница 28: ...DARAY Ltd Edison House Robian Way Swadlincote Derbyshire United Kingdom DE11 9DH 44 0 800 878 9864 44 0 333 321 0973 sales daray co uk www daray co uk...

Отзывы: