DARAY EXCEL Скачать руководство пользователя страница 5

 

Page 4 of 35 

1.2 Installation Notice 

With over 50 years of experience, DARAY take pride in offering consultancy and providing 
guidance on the installation and use of our lighting range.  
 
Should you ever require any advice with the installation or operation of one of our 
devices, please contact our Service Delivery Helpline on 

0800 878 9864

 or online at 

[email protected]

 We have a team of dedicated technical engineers and service 

representatives who are capable of providing guidance or bespoke solutions for most 
situations. 
 
DARAY offer installation services with our equipment. If you choose to opt out of our 
installation service, DARAY cannot be held responsible for the installation of the product 
detailed in your order. Should the product be incorrectly installed, violate health & 
safety, or cause injury to a third party, the responsibility is with the installer. As such we 
feel it necessary to provide the following general guidance. 

 

The location of each light should be given careful consideration; based upon the 
intended area, the lights reach, which part of the body the light is being used for 
and the preferences of the end user.  

 

Confirm the structural suitability of the installation area before commencing any 
work. If there is any doubt it may be necessary to involve structural engineers to 
verify suitability of the area. 

 

Commissioning of our light fittings should always be carried out in collaboration 
with the end users, 

 

Commissioning should include basic training in the operation of the unit before it 
is used 

 

This ensures that the units are correct for the user, installed in the correct 
location for the intended usage, and that sufficient provision has been made 
to avoid mishandling of the unit. 

 
Every effort is made to provide the most accurate and up to date instructions in the 
easiest manner but if you require more help we would like to encourage you to contact 
us, as any deviation or failure to adhere to our installation procedures can result in:  

 

limited movement of the light 

 

Improper functionality 

 

Lasting damage to the product 

 

Damage to the install location 

 

Health & Safety non-compliance  

 

And in extreme circumstances could cause physical injury 

 
If you are unsure of ANYTHING, please contact us before any attempt at installation is 
made. Customer safety is essential to us and it is our job to ensure optimum product 
performance in line with their design.  
 
If you have any questions relating to our products, or if you are seeking guidance in line 
with what is recommended above, please call our Service Delivery Helpline on 

0800 878 

9864

, or ask one of our dedicated Sales team. 

Содержание EXCEL

Страница 1: ...EXCEL LED Dental Examination Light Operating Installation Manual QAM EXCEL 0119 4...

Страница 2: ...Page 1 of 35...

Страница 3: ...5 Downtube adjustment and installation 16 4 1 6 Wiring and transformer layout 18 4 1 7 Arm installation 19 4 1 8 Fitting the lighthead 20 4 2 Wall Mounted Version EXCELW 21 4 2 1 Considerations 21 4...

Страница 4: ...ion guide contains all the information you need for installation operation and maintenance For further information on our product range and find out more about our company please visit www daray co uk...

Страница 5: ...fore commencing any work If there is any doubt it may be necessary to involve structural engineers to verify suitability of the area Commissioning of our light fittings should always be carried out in...

Страница 6: ...EXCELC EXCELCS Qty EXCELW EXCELWS Qty Ceiling Mount Plate 1 Wall Mount Bracket 1 1m 2m optional Downtube 1 Rotation and suspension arm system 1 Rotation and suspension arm system 1 Lighthead 1 Suspend...

Страница 7: ...Page 6 of 35 1 4 Technical Drawings...

Страница 8: ...Page 7 of 35...

Страница 9: ...K 5 Colour Rendering Index CRI 95 Colour Rendering R9 88 Light Field Diameter 0 7m 150mm x 70mm 20mm Number of LED s 6 Power Consumption 8 12W 2 Average Working Life 50 000 hours Input Voltage 100 240...

Страница 10: ...has two switch systems that can be used to power the light on or off a motion sensor and a manual switch The motion sensor is an infrared relay located underneath the lighthead fascia You can operate...

Страница 11: ...d the switch to increase or decrease intensity There is an audible beep from the unit when the light reaches one of its variable intensity peaks highest and lowest Note The variable intensity control...

Страница 12: ...e for cleaning but are NOT suitable for autoclaving To remove the handle hold it in one hand and press the lock button on the handle to release the locking mechanism Pull the handle away from the head...

Страница 13: ...Page 12 of 35 4 Installation Guide Section...

Страница 14: ...is a 2m downtube may be required For lights being installed into suspended ceiling area s a uni strut platform can be used to bring the fixing point down Live Electric Circuitry All personnel working...

Страница 15: ...quires the bottom of the ceiling plate to be no lower than 2290mm Bolted Directly into the structure and secured with chemical bonding The is our primary choice for mounting our lights to the ceiling...

Страница 16: ...ng the Ceiling plate The location of the light should be decided by the end user project manager or through schematical drawings Once the location has been decided it will be necessary to first mark t...

Страница 17: ...cut to length it will be necessary to de burr the end of the tube as this can help prevent damage to the cable Note when installed the downtube must leave clearance above the ceiling mount plate to p...

Страница 18: ...be directed use the two holes in the metal clamps to mark the location where the safety bolt will go through Remove the downtube and secure for drilling A 6mm hole should be drilled through the downtu...

Страница 19: ...have a Molex connection on the end This will attach to the opposite Molex connection from the transformer To connect the cabling from the transformer into the main power you will need to run this conn...

Страница 20: ...ver the primary arm spigot Using the sachet of silicon grease provided lubricate the indicated sections of the arm spigot Whilst inserting the arm spigot into the downtube boot feed the cable connecti...

Страница 21: ...htness and safety then the arm and head for smooth and correct freedom of movement rebalance the suspension arm if necessary Once checked and fully earthed the light can now be tested by applying powe...

Страница 22: ...e used for If in doubt consult the end user or DARAY When installing the bracket take consideration of where you want the lighthead to sit when in its lowest position Heavy or Difficult fittings Fitti...

Страница 23: ...Determine where to mount the wall bracket Align the bracket to the wall and mark your fixing points Ensure the bracket is completely true on both the horizontal and vertical planes as otherwise it ma...

Страница 24: ...e fixing points and then move the PSU back into position and insert appropriate fixings Feed the cable from the bottom of the light down through the bottom of its wall mount bracket and feed the cable...

Страница 25: ...htness and safety then the arm and head for smooth and correct freedom of movement rebalance the suspension arm if necessary Once checked and fully earthed the light can now be tested by applying powe...

Страница 26: ...nto the footplate using the 8nr grub screws on the sides of the collar Fig 4 4 Slight vertical adjustments can be achieved by adjusting the grub screws in out to push the upright to ensure the upstand...

Страница 27: ...35 The spring balanced arm within the dual arm system within the factory However if the springs have settled during transit you may need to adjust the tension See page 30 Section 6 Fig 1 Fig 2 Fig 3 F...

Страница 28: ...he hinge Remove arm clean spigot and re grease as necessary Check all electrical connections are sound and that there is no visible cable wear All fixings to be checked and be of sound construction 5...

Страница 29: ...ur BioProtect antimicrobial coating on painted finishes This is designed to assist with infection control and is not a replacement for cleaning CAUTION Our products are NOT waterproof The equipment an...

Страница 30: ...ed to the electrical supply For the ceiling mounted light the fuse is located on the ceiling plate within the terminal block connector The fuse tray can easily be removed and the fuse replaced The fus...

Страница 31: ...capstan located at the top of the jib arm can be seen when standing underneath the arm You will see stickers labelled 1 and 2 on either side of the capstan opening Step 3 TIP Grip the hex wrench as cl...

Страница 32: ...ower Button Please check the variable intensity is not just set to its minimum To do this hold in the power switch on the back of the head or use the infrared sensor These are the controls used to adj...

Страница 33: ...o the power cable or if exposed wire is visible DO NOT USE 8 Spare Parts CAUTION Use only genuine DARAY replacement lamps as other types may seriously impair the optical performance of the product ITE...

Страница 34: ...rges may be applicable OTHER Any situation which is not covered by any of the above We will always try to help but we cannot normally offer a refund For additional clarification please refer to our te...

Страница 35: ...Daray s instructions Attachment of fittings and accessories not approved by Daray Repairs modifications carried out by service personnel not approved by Daray Damage caused by chemical corrosion from...

Страница 36: ...Page 35 of 35 Service Notes...

Страница 37: ...Page 36 of 35...

Страница 38: ...Page 37 of 35...

Страница 39: ...Page 38 of 35...

Страница 40: ...DARAY Ltd Edison House Robian Way Swadlincote Derbyshire United Kingdom DE11 9DH 44 0 800 878 9864 44 0 333 321 0973 sales daray co uk www daray co uk...

Отзывы: