PCIe-SER01 User’s Manual
14
3-4 Test Board Connection
The table below is the PCIe_SER01 TEST port number connected to the program COM port
when connecting the PCIe-SER01 board and the PCIe-SER01_TEST (refer to Figure 2.3) board,
which is our test board. If the serial port is connected to RS232_0, the port number becomes
COM5 as shown in [Table 3].
(Notice) If you right-click on the Pericom Serial Port Device (COM) port and look at the
properties, you will see a location value that allows you to know the location of the
port. This location value is already set in the PC and there is a COM port in use, or it
can be changed according to the system specifications, so the user must select an
appropriate port.
Ex) If the value is “Location 2” in Properties->Location of COM3, it corresponds to
RS_232_2 port.
In COM10's Properties->Location, the value corresponds to “Location 7” or RS-232_8
port
[Table 3. PCIe-SER01과 PCIe-SER01_TEST Connection Description Example]
No.
PCIe-SER01
PCIe-SER01_TEST
Remark
1
COM3
RS-232_2
Port 3
2
COM4
RS-232_1
Port 4
3
COM5
RS-232_0
Port 5
4
COM6
RS-232_3
Port 6
5
COM7
RS-232_4
Port 7
6
COM8
RS-232_5
Port 8
7
COM9
RS-232_7
Port 9
8
COM10
RS-232_8
Port 10