background image

 

  

 

 

   

 

Splash Series Active / Passive 

Ordercode: D3588 – D3595 

Warning 

 
 

 
 

 
 

Unpacking Instructions 

 
Immediately upon receiving this product, carefully unpack the carton and check the contents to ensure 
that all parts are present and have been received in good condition. Notify the dealer immediately and 
retain packing material for inspection if any parts appear damaged from shipping or the carton itself 
shows signs of mishandling. Save the carton and all packing materials. In the event that a fixture must be 
returned to the factory, it is important that the fixture be returned in the original factory box and packing. 
 

Safety Instructions 

 
Every person involved with the installation, operation and maintenance of this device have to: 

-

 

be qualified 

-

 

follow the instructions of this manual 

 
 
 
 
 

 

 

Before your initial start-up, please make sure that there is no damage caused by transportation. Should 
there be any, consult your dealer and do not use the device. 

 

To maintain perfect condition and to ensure a safe operation, it is absolutely necessary for the user to 
follow the safety instructions and warning notes written in this manual. 

 

Please consider that damages caused by manual modifications to the device are not subject to 
warranty.  This device contains no user-serviceable parts. Refer servicing to qualified technicians only. 
 

IMPORTANT!

 

 
The manufacturer will not accept liability for any resulting damages caused by the non-
observance of this manual or any unauthorized modification to the system. 

 

 

Always disconnect power from the mains, when system is not used. Only handle the power-cord by 
the plug. Never pull out the plug by tugging the power-cord. 

 

Always operate the unit with the AC ground wire connected to the electrical system ground. 

 

Avoid flames and do not put close to flammable liquids or gases. 

 

Avoid ground loops! Always be sure to connect the power amps and the mixing console to the 
same electrical circuit to ensure the same phase! 

 

Avoid installing your equipment very near radio or TV sets, mobile phones, etc., as these can cause 
RF (radio frequency) interference. 

 

Before changing your grounds around, always turn your amplifiers down. 

 

Before connecting or disconnecting the power cord, make certain the ON / OFF switch is in the OFF 
position. 

 

Before switching on or off make certain the sound system’s amplifiers are off or turned down: this will 
avoid signal peaks, which are annoying and sometimes dangerous (particularly for speaker 

enclosures). 

 

Do not connect (parallel or series) an amplifier output with any other amplifier output. 

 

Do not connect this device to a dimmer pack. 

 

Do not drive the inputs with a signal level bigger, than required to drive the equipment to full output. 

FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY 

BEFORE YOUR INITIAL START-UP! 

CAUTION! 

Be careful with your operations. 

With a dangerous voltage you can suffer 

a dangerous electric shock when touching the wires! 

 

Содержание SPLASH 8

Страница 1: ...3494 D3595 D3592 D3593 Productname Splash 8A Splash 10A Splash 12A Splash 15A Splash 8 Splash 10 Splash 12 Splash 15 Splash Series Active Passive Highlite International B V Vestastraat 2 6468 EX Kerkr...

Страница 2: ...s 5 Panel Description Splash 8A 10A12A 15A 6 Panel Description Splash 8 10 12 15 7 Connection Example 8A 10A 12A 15A 8 Connection Example 8 10 12 15 9 Floor monitor setup 10 Connection Cables 11 Techn...

Страница 3: ...t accept liability for any resulting damages caused by the non observance of this manual or any unauthorized modification to the system Always disconnect power from the mains when system is not used O...

Страница 4: ...use the wrong kind of cables or defective cables Make sure you use DI boxes to balance unbalanced signals All incoming signals should be clear Never let the power cord come into contact with other cab...

Страница 5: ...on proper UPS packing or double boxing is always a safe method to use Note If you are given an RMA number please include the following information on a piece of paper inside the box 1 Your name 2 Your...

Страница 6: ...portation and a pole mount The special shaped side and the excellent gain before feedback makes it also possible to use the Splash series as a stage monitor speaker These properties make this series s...

Страница 7: ...ne MIC input on combo connector Input sensitivity switch for Line or MIC Link out Main Volume control Clip indicator Power indicator Countour on off Contour ON preset is to equalize the mix for optima...

Страница 8: ...D3595 Panel Description Splash 8 10 12 15 INPUT Receive the power coming from an external power amplifier SPK 1 1 connected 2 2 not connected THRU Direct LINK for connecting in parallel a second speak...

Страница 9: ...8 Splash Series Active Passive Ordercode D3588 D3595 Connection Example 8A 10A 12A 15A...

Страница 10: ...9 Splash Series Active Passive Ordercode D3588 D3595 Connection Example 8 10 12 15...

Страница 11: ...10 Splash Series Active Passive Ordercode D3588 D3595 Floor monitor setup...

Страница 12: ...increasing their life and reliability Periodically check your cables A great number of problems faulty contacts ground hum discharges etc are caused entirely by using unsuitable or faulty cables Unbal...

Страница 13: ...feet 1 handle on top Mounting 35mm pole mount Connectors Combo XLR male female link Dimensions H x W x D 420 x 270 x 240 mm Weight 5 53Kg Splash 10A System Bi Amp 2 Way Active Speaker Continuous powe...

Страница 14: ...c handles Mounting 35mm pole mount Connectors Combo XLR male female link Dimensions H x W x D 607 x 380 x 337mm Weight 13 75Kg Splash 15A System Bi Amp 2 Way Active Speaker Continuous power Low 150W H...

Страница 15: ...l Grill Rubber feet 1 handle Mounting 35mm pole mount Connectors Speakon Dimensions H x W x D 420 x 270 x 240 mm Weight 5 81Kg Splash 10 System Passive 2 Way Full range Speaker Continuous power 120W P...

Страница 16: ...ber feet 3 ergonomic handles Mounting 35mm pole mount Connectors Speakon Dimensions H x W x D 607 x 380 x 337mm Weight 11 75Kg Splash 15 System Passive 2 Way Full range Speaker Continuous power 200W P...

Страница 17: ...16 Splash Series Active Passive Ordercode D3588 D3595 Frequency Response Diagram Splash 8A Splash 10A Splash 12A Splash 15A...

Страница 18: ...17 Splash Series Active Passive Ordercode D3588 D3595 Splash 8A Splash 10A Splash 12A Splash 15A...

Страница 19: ...unit operates properly do not carry out following steps 1 If the device does not operate properly unplug the device 2 Check the fuse power from the wall all cables etc 3 If all of the above appears to...

Страница 20: ...2014 DAP Audio...

Отзывы: