Marani Dig Amp software 

 

The LT-series gives you the opportunity to edit the Factory preset programs to your own preferences or 
back them up.  
 

Note: You’ll have to buy the optional USB to RS485 interface first. You can download the software from our 
website. 

 
 

Editing Window

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

   Fig. 3 

 
Input Gain

:  

This slider allows you to set the input gain. Range -60db – 0dB. 

 
Parametric filters

 

A five band parametric EQ is available on the Digital Amp DSP Board for equalizing each output 
channel. Each of the five parametric filters can be edited in terms of Gain, Center Frequency and 
Quality Factor “Q”. 
1. The Gain can be set by using the slider which allows you to attenuate/increase the filter's output  
    ranging from -15dB up to +15dB. 
2. The Quality Factor “Q”, can be set by selecting the proper value from the selection field on the bottom  
    row. Range from 0.40 (wide bell) up to 128 (thin notch). 
3. The Center Frequency can be set by “double clicking” on the entry field just beneath the Gain slider.  
    After double clicking, a window will open allowing you to set all the filter's parameters by sliders. It is  
    also possible to enter the frequency by clicking the entry field and entering the value using your  
    computers keyboard. 
 

Lo-Shelving

  

The Low Shelving field allows the user to adjust the parameters of a Low Shelving filter. 
1. filter attenuation/gain, which can be set by the slider and ranging between -12dB up to +6dB 
2. Cutting Frequency, click the entry field below the slider and use your computers keyboard to enter the  
    desired frequency. 
3. filter's order (or Bypass), which can be of the first (6dB/Oct) or of the second (12dB/Oct) order. 

 
Hi-Shelving 

The High Shelving field allows the user to adjust the parameters of a High Shelving filter.  
1. filter attenuation/gain, which can be set by the slider and ranging between -12dB up to+6dB 
2. Cutting Frequency, click the entry field below the slider and use your computers keyboard to enter the  
    desired frequency. 
3. filter's order (or Bypass), which can be of the first (6dB/Oct) or of the second (12dB/Oct) order. 

Содержание LT-215A

Страница 1: ...LT 215A ORDERCODE D3474...

Страница 2: ...Audio for more excellent audio products We design and manufacture professional audio equipment for the entertainment industry New products are being launched regularly We work hard to keep you our cu...

Страница 3: ...ct Guide Warning Unpacking Instructions Safety instructions Operating Determinations Return Procedure Claims Description Features Overview Control Panel Marani Dig Amp Software Operation Connection Ca...

Страница 4: ...To maintain perfect condition and to ensure a safe operation it is absolutely necessary for the user to follow the safety instructions and warning notes written in this manual Please consider that da...

Страница 5: ...ounding frequency ranges instead This way you avoid causing the next piece of equipment in your sound path to overdrive You also preserve valuable dynamic reserve headroom Avoid ground loops Always be...

Страница 6: ...ethod to use Note If you are given an RMA number please include the following information on a piece of paper inside the box 1 Your name 2 Your address 3 Your phone number 4 A brief description of the...

Страница 7: ...e enclosure 2 high power 15 inch drivers 3 inch compression driver Built in DSP Bang Olufsen ICE power amplifiers Strong metal handles Multiple flying system Interlock system for safe ground stacking...

Страница 8: ...gh a soft clipping circuit limits your dynamic range it allows you to operate on higher volume levels Protect Indicates an electrical or thermal fault condition in the power amp 4 RS 485 Termination o...

Страница 9: ...it Note Please make sure that the supply voltage matches the operation voltage before connecting the unit to mains 12 Powercon AC power link output This connector is meant for the connection of the su...

Страница 10: ...e clicking on the entry field just beneath the Gain slider After double clicking a window will open allowing you to set all the filter s parameters by sliders It is also possible to enter the frequenc...

Страница 11: ...e more less buttons and can range from 1ms up to 480ms The Bypass button allows the user to bypass the compressor with one touch Volume This slider allows you to set the Signal output Level after the...

Страница 12: ...and it will be possible to recall it later by using the Open Folder option Save Preset to Device The Save Preset to Device on the top of the screen allows the user to SAVE an edited setting as preset...

Страница 13: ...king materials from the LT 215A Check that all foam and plastic padding is removed Connect all cables Always disconnect from electric mains power supply before cleaning or servicing Damages caused by...

Страница 14: ...em This gives the advantage of increasing their life and reliability Periodically check your cables A great number of problems faulty contacts ground hum discharges etc are caused entirely by using un...

Страница 15: ...the fuse cover Gently pry up the fuse cover 3 Remove the used fuse If brown or unclear it is burned out 4 Insert the replacement fuse into the holder where the old fuse was Reinsert the fuse cover Be...

Страница 16: ...Watt RMS in 4 Ohm Amplifier Output High 500 Watt RMS in 4 Ohm Damping factor at 100 Hz 2000 in 8 Ohm Input Sensitivity 0 dBu DSP Marani Dig Amp DSP Freq Response 3 dB 56 15 000 Hz Freq Range 10 dB 42...

Страница 17: ...2011 Dap Audio...

Отзывы: