background image

 

 

 

6 

 

  

 

 

CA-4150 

Product code: D4512 

 

Attention 
General safety
 

 

Do not block the ventilation openings. Without proper heat dissipation and air circulation, the 
internal components may overheat. This can result in product damage. 

 

Do not shake the device. Avoid brute force when installing or operating the device. 

 

If the device is dropped or struck, disconnect the device from the electrical power supply 
immediately. 

 

If the device is exposed to extreme temperature variations (e.g. after transportation), do not switch it 
on immediately. Let the device reach room temperature before switching it on, otherwise it may be 
damaged by the formed condensation. 

 

If the device fails to work properly, discontinue the use immediately. 

 

Attention 
This device shall be used only for the purposes it is designed for. 

This device is designed to be used as an amplifier. Any incorrect use may lead to hazardous situations 
and result in injuries and material damage. 

This device does not contain user-serviceable parts. Unauthorized modifications to the device will render 
the warranty void. Such modifications may result in injuries and material damage. 

 

Attention 
Do not expose the device to conditions that exceed the rated IP class conditions. 

This device is IP20 rated. IP (Ingress Protection) 20 class provides protection against solid objects greater 
than 12 mm, such as fingers, and no protection against harmful ingress of water. 

 

Requirements for the User 

This product may be used by ordinary persons. Maintenance and installation may be carried by ordinary 
persons. Service shall be carried out only by instructed or skilled persons. Contact your Highlite 
International dealer for more information. 

Instructed persons have been instructed and trained by a skilled person, or are supervised by a skilled 
person, for specific tasks and work activities associated with the service of this product, so that they can 
identify risks and take precautions to avoid them. 

Skilled persons have training or experience, which enables them to recognize risks and to avoid hazards 
associated with the service of this product. 

Ordinary persons are all persons other than instructed persons and skilled persons. Ordinary persons 
include not only users of the product but also any other persons that may have access to the device or 
who may be in the vicinity of the device. 

 

 

Содержание CA-4150

Страница 1: ...CA 4150 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Product code D4512 USER MANUAL ENGLISH V2...

Страница 2: ...Non observance of the instructions in this user manual may result in serious injuries and damage of property 2022 DAP All rights reserved No part of this document may be copied published or otherwise...

Страница 3: ...Precautions 10 Turning On Off 11 Setting Gain 11 5 4 LED Statuses 11 Setting Cutoff Frequency 11 Setup Examples 11 Mode 1 Ch A B C D All Stereo 12 Mode 2 Ch A B C D All Parallel 13 Mode 3 Ch A B Brid...

Страница 4: ...uko to IEC power cable 1 5 m User manual Fig 01 Intended Use This device is intended for professional use as an amplifier It is suitable only for indoor installation Any other use not mentioned under...

Страница 5: ...tant Read and observe the instructions in this document Electrical hazard Provides important information about the disposal of this product Symbols on the Information Label This product is provided wi...

Страница 6: ...put pressure on pull or heat up the power cable Make sure that the power cable is not crimped or damaged Examine the power cable periodically for any defects Do not immerse the device in water or oth...

Страница 7: ...modifications may result in injuries and material damage Attention Do not expose the device to conditions that exceed the rated IP class conditions This device is IP20 rated IP Ingress Protection 20 c...

Страница 8: ...04 PROT CLIP SIGNAL LED indicators CH C D 05 Ventilation openings 06 Gain controls CH C D 07 Gain controls CH A B Back View Fig 03 08 2 pin terminal CH A speaker connector OUT 09 2 pin terminal CH B s...

Страница 9: ...e output power 4 20 Hz 20 kHz 275 W Output channels 4 Output gain 28 dB Output mode 4 channel Bridge Stereo Output impedance Stereo min 4 Bridge 8 Inputs Mono inputs 4 Mono input impedance 20000 Mono...

Страница 10: ...n Make sure there is enough space for ventilation around the device Do not block the ventilation openings Without proper heat dissipation and air circulation the internal components may overheat This...

Страница 11: ...other voltage or frequency to the device This device falls under IEC protection class I Make sure that the device is always electrically connected to the ground earth Before connecting the device to t...

Страница 12: ...D is red the amplifier is operating at its limits Turn off the device and identify the problem Decrease the source signal level and improve air circulation in the room where the device is installed CL...

Страница 13: ...orrect positions See the table below Operation Mode DIP switches Description 1 2 3 MT 1 OFF OFF OFF OFF Ch A B C D all stereo 2 ON OFF OFF OFF Ch A B C D all parallel 3 OFF ON OFF OFF Ch A B bridge Ch...

Страница 14: ...13 CA 4150 Product code D4512 Mode 2 Ch A B C D All Parallel Fig 06...

Страница 15: ...14 CA 4150 Product code D4512 Mode 3 Ch A B Bridge Ch C D Bridge Fig 07...

Страница 16: ...15 CA 4150 Product code D4512 Mode 4 Ch A B Parallel Ch C D Parallel Fig 08...

Страница 17: ...16 CA 4150 Product code D4512 Mode 5 Ch A B Stereo Ch C D Bridge Full Range Fig 09...

Страница 18: ...17 CA 4150 Product code D4512 Mode 6 Ch A B Parallel Ch C D Bridge Full Range Fig 10...

Страница 19: ...18 CA 4150 Product code D4512 Mode 7 Ch A B Stereo Sub Ch C D Bridge Input Ch C Fig 11...

Страница 20: ...19 CA 4150 Product code D4512 Mode 8 Ch A B Stereo Sub Ch C D Bridge Input Ch A B Fig 12...

Страница 21: ...nd external devices are correct Bursts of noise or other audible signals present Sources of interference are present Identify potential sources of interference and turn them off The protection indicat...

Страница 22: ...r supply may cause a fuse to burn out If the fuse burns out the device will not function anymore If this happens follow the steps below 01 Disconnect the device from the electrical power supply 02 All...

Страница 23: ...t by handing it to the respective collection point for recycling of electrical and electronic equipment This is to avoid environmental damage or personal injury due to uncontrolled waste disposal For...

Страница 24: ...2022 DAP...

Отзывы: