Rack Mounting
The device can be mounted in a standard 19-inch rack. The device requires 1 rack unit (U) of space,
which is 44,5 mm high.
Make sure that the rack is sufficiently secured to prevent it from becoming unstable or falling over.
To mount the device in a two-post rack, follow the steps below:
01)
Insert 4 cage nuts in the openings on the rack posts where you want to mount the device.
02)
Position the device in front of the rack posts so that the 4 mounting openings on the flanges face the
openings on the rack posts with cage nuts.
03)
Using a screwdriver, mount the device to the rack posts with 4 screws.
Connecting to Power Supply
DANGER
Electric shock caused by short-circuit
The device accepts AC mains power at 220–240 V and 50 Hz. Do not supply power at any other voltage
or frequency to the device.
This device falls under IEC protection class I. Make sure that the device is always electrically connected
to the ground (earth).
Before connecting the device to the socket-outlet:
●
Make sure that the power supply matches the input voltage specified on the information label on
the device.
●
Make sure that the socket-outlet has ground (earth) connection.
Connect the device to the socket-outlet with the power plug.
5.
Setup and Operation
Warnings and Precautions
Attention
Connect all cables before supplying power.
Disconnect power supply before connecting or disconnecting cables.
For more information about the control modes, refer to 5.6. Setup Examples on pages 11–19.
Attention
This device must be used only for the purposes it is designed for.
This device is intended for use as an amplifier. It is suitable only for indoor installation. It is not suitable for
households.
Any other use, not mentioned under intended use, is regarded as non-intended and incorrect use.
Содержание CA-4150
Страница 14: ...13 CA 4150 Product code D4512 Mode 2 Ch A B C D All Parallel Fig 06...
Страница 15: ...14 CA 4150 Product code D4512 Mode 3 Ch A B Bridge Ch C D Bridge Fig 07...
Страница 16: ...15 CA 4150 Product code D4512 Mode 4 Ch A B Parallel Ch C D Parallel Fig 08...
Страница 17: ...16 CA 4150 Product code D4512 Mode 5 Ch A B Stereo Ch C D Bridge Full Range Fig 09...
Страница 18: ...17 CA 4150 Product code D4512 Mode 6 Ch A B Parallel Ch C D Bridge Full Range Fig 10...
Страница 19: ...18 CA 4150 Product code D4512 Mode 7 Ch A B Stereo Sub Ch C D Bridge Input Ch C Fig 11...
Страница 20: ...19 CA 4150 Product code D4512 Mode 8 Ch A B Stereo Sub Ch C D Bridge Input Ch A B Fig 12...
Страница 24: ...2022 DAP...