background image

R

www.danvex.fi

DEHUMIDIFIER DESCRIPTION

The unit is designed for automated, versatile and trouble-free  air dehumidification. Due to its 
compact dimensions it is easy to transport and operate.

The unit operates on condensation principle. It is equipped with a closed loop cooling system, 
low noise and low maintenance fan and with a power cable with a plug. The unit's control 
panel is equipped with indicators used for the system functional checks. A fully automated unit 
control system, a trouble-free regulated humidistat, an integrated overflow system as well as 
flexible hose connection for direct  condensation discharge assure fail safe and long-term 
operation of the unit.  The unit complies with the fundamental safety and health requirements 
of the existing EU regulations. The unit is easy and safe to operate.

5

Содержание DEH-1000P

Страница 1: ...DEH 600P 1000P Air dehumidifiers Operation manual...

Страница 2: ...R www danvex fi...

Страница 3: ...vex fi CONTENT Air dehumidification 3 Precautions 4 Dehumidifier description 5 Location and functions 6 Design 7 Control panel 8 Water tank and continuous drainage 9 Specifications 10 Support and warr...

Страница 4: ...ugh thick concrete walls It can take 1 2 months for the water used for construction concrete works whitewashing plasterworks etc to dry out The moisture that has penetrated masonry following high wate...

Страница 5: ...tage specified in the table 8 Please note that this unit is designed for domestic use only It is intended for household needs 9 It is not allowed to put heavy objects on the dehumidifier 10 Before tra...

Страница 6: ...tenance fan and with a power cable with a plug The unit s control panel is equipped with indicators used for the system functional checks A fully automated unit control system a trouble free regulated...

Страница 7: ...es cellar rooms It is also used for dry air maintenance in Storage areas archives laboratories Bathrooms laundries changing rooms etc FUNCTIONS The unit operates on condensation principle The fan inta...

Страница 8: ...R www danvex fi 1 Control panel 2 Air outlet 3 Handles 4 Front panel 7 5 Air intake filter 6 Drain hole 7 Condensate tank DESIGN...

Страница 9: ...to the mains power supply 3 Set turn the humidity regulator to the desired humidity value 60 position 4 9 8 7 6 5 4 3 2 1 10 20 30 40 50 60 70 80 90 Regulator position number Humidity Switching off t...

Страница 10: ...or TANK FULL lights up Compressor and fan stop 2 Pull the water tank and remove it Drain the water and place the tank back Continuous drainage If you want to use this function please pull the water ta...

Страница 11: ...orinated greenhouse gases covered by the Kyoto Protocol Its total global warming potential GWP is 1975 This marking indicates that this product should not be disposed with other household wastes throu...

Страница 12: ...operation All recommendations and instructions of the manufacturer concerning the equipment installation operation and maintenance were observed Only original parts and materials were used for the equ...