manualshive.com logo in svg
background image

R

www.danvex.fi

4

Introduction

This  specification  is  a  technical  document  that  certifies  the 

DanVex AD-200

  dehumidifier 

parameters and characteristics.

Purpose

DanVex AD-200 (

in

 

short 

AD-200) 

is  designed  for  efficient  air  dehumidification  with  the  air 

humidity  up  to 

 100%, 

at  the  temperature  from

 –

2

0ºС 

to

 +40ºС 

with  minimum  energy 

consumption

.

 It can be used either as an 

independent unit 

for installation inside and outside of 

premises where air humidity control is required or along with an air treatment system

.

Design

The dehumidifier answers

 

IP 44 protection

 

class according to 

IEC.

Body

The dehumidifier body is made of stainless steel

The front part of the dehumidifier is equipped 

with  a  detachable  panel  that  assure  access  for  maintenance

Air  ducts  are  connected  via 

standard size round air ducts

The e

lectric panel 

is located in a separate section in the humidifier 

upper part

the control panel is located on the dehumidifier front part

Rotor

The  dehumidifier  is  equipped  with  a  drying  rotor  manufactured  in  accordance  with  unique 
technologies covered by a patent in force

The rotor represents a matrix consisting of numerous 

air  channels.  It  is  made  of  composite  material

 

with  introduced

 SelicaGel 

and  assures  a  very 

large contact area with air flow for moisture adsorption in the small volume of the rotor. This 
material is highly efficient for water molecules attraction and retention

it is noncombustible and 

explosion-proof

,

 with a long service life. The rotor manufacturing technology assures production 

of a product capable of saturated air processing without risk of destruction

it means that the 

rotor can be used along with a precooler

Besides

,

 the rotor will not be damaged even if the fan or 

the reactivation air heater fail to function

.

Filters 

The dehumidifier is equipped with two filters

.

 One filter is located at the dehumidified air inlet, the 

another one is installed at the reactivation air inlet. 

 

Air flow fans

:

 for dehumidified air flow and for reactivation air flow

The fans are of a radial type, single phase, 

IP 54

 class

, ISO F.

 The fans maintenance can be 

performed after the service panels are removed

.

Electric panel

Electrical components are located inside the dehumidifier and can be reached through the top 
panel. Switches and indicators are located in the front part of the electric panel. 

Reactivation air heater

The  reactivation  air  heater  is  of 

PTC (Positive Temperature Control)

  type

,

  its  overheating  is 

impossible

.

Control panel

Different operation modes can be selected using the switches located in the front panel

:

0/OFF  

– 

The dehumidifier does not operate

.

1/

ON

  – 

The dehumidifier is in operation mode

.

MAN   – 

The dehumidifier operates in a continuous mode

.

AUTO  

– 

Automatic mode at using an external humidistat  or at connecting other 

external 

control device

s

.

Содержание AD-200

Страница 1: ...DanVex AD 200 Adsorption air dehumidifier Operation manual...

Страница 2: ...R www danvex fi...

Страница 3: ...T Safety instructions 3 Introduction 4 Purpose 4 Design 4 Operation principle 5 Dimensions and weight 5 Installation 6 Technical data 7 Commissioning 7 Maintenance 8 Transportation 8 Parts list 9 Warr...

Страница 4: ...osion hazard Before opening any panels of the unit body it is required to disconnect the dehumidifier from the mains Before starting any maintenance works the dehumidifier should be out of operation f...

Страница 5: ...l volume of the rotor This material is highly efficient for water molecules attraction and retention it is noncombustible and explosion proof with a long service life The rotor manufacturing technolog...

Страница 6: ...humidification process is assured The air flow used for the rotor matrix regeneration is called regeneration air REGENERATION AIR It is heated up to 120 and when passing through a small sector it remo...

Страница 7: ...stall the moist air duct upright it should be insulated and drain holes should be drilled in the lowest part of the elbow bend 2 4 mm Regeneration air duct The regeneration air duct should be as short...

Страница 8: ...required RH value when doing so 5d should be displayed in the upper line the bottom line should display the value being set Then set the humidity change value relative to the set value at which the d...

Страница 9: ...once per month Never use the dehumidifier without filters Rotor The rotor is maintenance free However for cleaning purposes it can be flushed out by compressed air A rotor cleaning procedure requires...

Страница 10: ...danvex fi Parts list Table 3 Rotor drive motor 9 1 Name Number per dehumidifier Condenser 1 Belt pulley 1 Rotor drive belt 1 Belt tensioner 1 Dehumidified air fan 1 Regeneration air fan 1 Heater 1 Ro...

Страница 11: ...tions when it supplies the Customer a repaired or a spare part Parts repair or replacement does not result in the warranty period extension The parts and components replaced under the warranty belong...

Страница 12: ......

Отзывы: