►►5.1. TANK:
IT IS RECOMMENDED TO READ THE SAFETY
WARNINGS CAREFULLY AND TO CHANGE THE
WATER FREQUENTLY.
►5.1.1. Turn off the cooler and disconnect the plug
from the power mains.
►5.1.2. Drain the tank through the specific drain
cock (PIC. 7).
►►5.2. EVAPORATIVE PANELS AND WA
-
TER CIRCUIT:
►5.2.1. It is recommended to visually check the con
-
dition and correct position of the evaporative pan
-
els on a regular basis (PIC. 8). The panels must
not be worn, damaged or encrusted and must be
positioned correctly in order to avoid gaps be
-
tween each other.
IMPORTANT: Do not attempt to remove the evap
-
orative panels. All operations must be carried out
by the after-sales assistance service.
IMPORTANT: Handle the evaporative panels with
care; do not drill or insert pointed objects in the air
inlet grille.
►5.2.2. To ensure proper operation of the cooler,
turn off the COOL mode a few minutes before
completely switching off the cooler, in order to
avoid stagnant water.
►5.2.3. We recommend periodically performing a
complete filling and draining cycle of the water
circuit using clean water and appropriate disinfec
-
tion products, running the cooler outdoors until the
tank contents are emptied completely.
IMPORTANT:
-The cooler tank must be emptied and sanitised pe
-
riodically depending on the use.
-The evaporative panel surfaces must be periodi
-
cally inspected and sanitised depending on the use.
-For sanitation operations, biocidal products that
comply with European regulation no. 582/2012 must
be used.
►►5.3. AIR FILTER (applicable depending
on the model) (PIC. 9):
WARNING: A dirty air filter can lead to a signifi
-
cant drop in performance of the cooler.
IT IS RECOMMENDED TO CLEAN THE AIR FIL
-
TER OFTEN TO MAINTAIN THE COOLER IN
GOOD CONDITION.
►5.2.1.
Turn off the cooler and disconnect the plug
from the power mains.
►5.2.2.
Remove the fixing screws (if present) and
remove the filter.
►5.2.3.
Clean the filter using a mild detergent and a
soft cloth. Make sure that the filter is perfectly dry.
►5.2.4.
Refit the filter and secure it with the screws
(if present).
►►6. REMOTE HUMIDISTAT CONNEC
-
TION (optional)
A remote humidistat can be connected in series to
the power supply plug, to manage automatic switch-
on or switch-off of the cooler.
After the humidistat has been activated, during nor
-
mal operation, the cooler switches off. The re-igni
-
tion is automatic and the operating configuration is
restored keeping the settings prior to switch-off.
CAUTION: THE ONLY SETTING THAT IS NOT
RESTORED IS THE “TIMER” FUNCTION, IN THIS
CASE IN FACE THE COOLER WILL GO IN STAND-
BY CONDITION.