Spare parts list 

 

 

List 

Below are the complete list of spare parts with part numbers: 

 

Spare part 

Type 

Part number 

Compact filter 

F5, 670 x 295 x 70 mm 

900-07633417 

Fan 48V DC 

W1G250-HH67-52, 48 V DC 

023-92184831 

Fan 230V AC 

W2E250-HL06-01, 230V AC 

023-92184844 

Control Unit 48V DC 

BCT 48 

500-24771619 

Indoor temp. sensor 

RTT-1 

889-350203 

Filter monitor 

JDW5 

021-422314 

 

 

Contact 

In the table below you can see how to contact the manufacturer and sales offices. 

 

Office 

Sweden 

Norway 

Denmark 

Name Kontrollelektronik 

Dantherm Air Handling AB 

A/S Dantherm avd. 
Kontrollelektronik 

Dantherm Air Handling A/S 

Address 

Virkesgatan 5 

Postboks 147 / 
Storgatan 29 

Marienlystvej 65 

 

SE-614 31 Söderköping 
Sweden 

NO-1851 Mysen 
Norway 

DK-7800 Skive 
Denmark 

Phone 

+46 (0)121 130 40 

+47 69 89 37 67 

+45 96 14 37 00 

Fax 

+46 (0)121 133 70 

+47 69 89 47 35 

+45 96 14 38 20 

E-mail [email protected] 

[email protected] [email protected] 

Web kontrollelektronik.com www.dantherm.no www.dantherm-air-handling.com 

 

 

 

Содержание KONTROLLELEKTRONIK FCB 773

Страница 1: ...U Manuals FCB FCB 773 EN pdf 1 10 2009 02 05 Free Cooling Box FCB 773 Service manual...

Страница 2: ...e 9 Spare parts list 10 Contact In the table below you can see how to contact the manufacturer and sales offices Office Sweden Norway Denmark Name Kontrollelektronik Dantherm Air Handling AB A S Danth...

Страница 3: ...006 95 EG Low Voltage Directive including 93 68 EEC where required 86 336 EEC EMC Directive including 92 31 EEC and 93 68 EEC 89 392 EEC Machine Directive The product is manufactured according to SS E...

Страница 4: ...280 W 275 W Sound pressure at 3m from shelter Approx 40dBA Approx 40dBA External available pressure drop 50 Pa 50 Pa Cabinet data Data of the cabinet are shown in the following table Specification Des...

Страница 5: ...filter Type Compact filter Removal efficiency F5 Dimensions 670 x 295 x 70 Total Area 4 3 m2 Filter monitor setting 85 Pa at 6V DC signal Controlling The table below show the components and types for...

Страница 6: ...U Manuals FCB FCB 773 EN pdf 6 10 2009 02 05 Dimensions Illustration This drawing illustrates the dimensions of the Free cooling unit Side Front...

Страница 7: ...U Manuals FCB FCB 773 EN pdf 7 10 2009 02 05 Flow illustration Flow The picture below schematically shows the air flow Default inlet Alternative inlet...

Страница 8: ...A2 PA1 Brown Blue 3 4 5 6 7 Brown White Blue White Green Tc 0 10V Tc 0 10V 1 2 6 5 Green 1 3 t 2 Fan alarm output Brown White BCT 48 0 100 Room termostat Fans Main supply 48VDC BCT 48 090120 PA2 Viole...

Страница 9: ...The documentation could be in form of a written log Recommended approach The recommended approach when performing a preventive maintenance visit is Step Action 1 Make sure that the power to the unit i...

Страница 10: ...In the table below you can see how to contact the manufacturer and sales offices Office Sweden Norway Denmark Name Kontrollelektronik Dantherm Air Handling AB A S Dantherm avd Kontrollelektronik Danth...

Отзывы:

Похожие инструкции для KONTROLLELEKTRONIK FCB 773