26
INSTALLATION & SERVICE MANUAL FOR PROFESSIONALS
Installation Options
: Switching between modes A and B
Installation Options
Switching between modes A and B
The HCV series has the option of swapping the duct connections according to the description
in section “Product description” -”General description”. This section will guide you through the
process of switching from operating mode A to B.
Injury caused by electric shock and risk of damage to the device
• Always ensure that the power is switched off before dismantling the unit
and before changing the operating mode using the A-B function switch
The air ducts leading the air into the house can be connected either on the right or left side at
the top of the unit. Mode A is the default setting.
If the installation requires mode B, follow the procedure below AND check the label to make
sure the water outlet is connected correctly.
Follow these steps when switching the mode:
Step Action
Illustration
1
Place the new B sticker on top of
the unit.
2
Remove the upper part of the
front cover.
3
Release the two screws at the
upper left and right corners
(underneath the upper part of the
front cover).
4
Remove the remaining part of the
front cover.
5
Place the new calibration sticker
on the heat exchanger.
Introduction
Warning
Caution
CAUTION
Selection Mode
Change to
mode B
1
4
5
2
3