21
093683
• Versio
n
1.4• 19.
04.20
17
Changing the air flow path
Introduction
HCV300 allows the user to electronically swop the air flows through the unit.
This section describes the change between A and B
mode.
Warning
The unit must always be disconnected from the power supply before accessing the live
wiring and rotating parts and before changing the air flow path on the main control.
Select mode
The air ducts going into the house can either be connected on the right hand side or the
left hand side of the top of the unit. The default mode is mode A with the house ducts
going out to the left. If local systems demands mode B, follow the below procedure AND
follow the label or description at page 6 to connect the water drainage correct.
Labels
Note: if you swop air flows remember to also exchange label on the unit so it corre-
sponds to the correct mode.
Continued overleaf