background image

9

Outdoor Air Flow Up

4x

8 mm

4 mm

3 mm

2x

Center

8 mm

4 mm

3 mm

2x

Center

15mm

10mm

Mount bracket 

Flexibox 900 Outdoor

Mount unit 

Flexibox 900 Outdoor

Содержание Flexibox 900

Страница 1: ...1 Flexibox 900 Quick setup guide Rev 1 3 20 3 2017...

Страница 2: ...door version 16 Product dimensions Indoor version 17 Cut hole and mount unit Indoor version 18 Operation 15 Mandatory electrical connection 21 Install and connect controller CC3000 22 Diagram Controll...

Страница 3: ...uld be performed by qualified personal using safe work practices All proper personal protective equipment should be used PPE required for this installation includes but is not limited to Safety glasse...

Страница 4: ...4 Flexibox 900 Indoor flow Intake Outlet Flexibox 900 Outdoor down flow Flexibox 900 Outdoor up flow Intake Intake Outlet Outlet...

Страница 5: ...5 1x 1x 1x 2x 1x Tools needed...

Страница 6: ...connector 2 pos 48V 1 1 Indoor Sensor 1 1 1 1 Internal Air Hood 1 1 Nylon Cable Clamps 2 2 2 2 Weather strip 1 1 Screws 4x12 PH T20 Hardened 8 8 Suspension bracket 1 1 Brace Protection 1 1 Machine sc...

Страница 7: ...overview Product dimension Flexibox 900 Outdoor Intregrated rainhood fan Filter Airflow outside air inlet Safety grill front Installation bracket 455 mm 18 inch 472 mm 18 6 inch 758 mm 29 9 inch 500...

Страница 8: ...8 Outdoor Air Flow Up minimum 900mm 35 5 inch 225 mm 8 9 inch 430 mm 17 inch 1 40mm 3 2 8 mm 4 mm 3 mm 8 mm 4 mm 3 mm Prepare unit Flexibox 900 Outdoor Cut hole Flexibox 900 Outdoor...

Страница 9: ...9 Outdoor Air Flow Up 4x 8 mm 4 mm 3 mm 2x Center 8 mm 4 mm 3 mm 2x 15mm 10mm Mount bracket Flexibox 900 Outdoor Mount unit Flexibox 900 Outdoor...

Страница 10: ...10 Outdoor Air Flow Up Seal unit Flexibox 900 Outdoor...

Страница 11: ...earth Connect earth Flexibox 900 Outdoor Mount indoor sensor Flexibox 900 Outdoor Keep sensor clear of surfaces For installation and use of the CC3000 controller please refer to the installation sect...

Страница 12: ...12 Outdoor Air Flow Down 430 mm 17 inches 225 mm 8 9 inches Min 150 mm 6 inches Cut hole 8 mm 4 mm 3 mm Remove front to access interior 40mm 2 3 1 8 mm 4 mm 3 mm...

Страница 13: ...13 Outdoor Air Flow Down FB 900 Outdoor Air flow down Mount bracket 1 362 mm 14 2 inches Fasten FB 900 to the wall bracket 2...

Страница 14: ...14 Outdoor Air Flow Down FB 900 Outdoor Air flow down Rainhood Bend metal flaps 90 Secure hood to wall using screws below and above the hood Mount rainhood on FB and secure with screws...

Страница 15: ...15 Outdoor Air Flow Down Mount unit Flexibox 900 Outdoor 4x 8 mm 4 mm 3 mm Seal unit...

Страница 16: ...16 Indoor Integrated hood Filter Safety grill Front Support bracket Protective bracket Air flow Product overview...

Страница 17: ...17 Indoor Dimensions...

Страница 18: ...18 Indoor 370 mm 400 mm 800 mm 16 mm 665 mm Cut hole Flexibox 900 Indoor Note The three holes in the bottom of the Flexibox 900 can be used for attatching cable ties with clips Mounting...

Страница 19: ...t bracket Make sure the flaps of the support bracket fits in the slits in the bottom of the FB900 3 Mark and drill two holes for screws Use plugs if necessary 4 Fasten the screws Mount outdoor tempera...

Страница 20: ...900 Indoor External Rain hood for Flexibox 900 Indoor Dantherm offers the following weather protection solutions Art No Description 299653 External rain hood 075575 AirMaze Panel unpainted 086924 AirM...

Страница 21: ...8V DC 16A fused 2 5 mm2 wires AWG 13 External safety breaker 1 2 2 1 2x2 5 mm AWG 13 1 2 3 4 5 6 7 8 Flexibox 900 DC Flexibox 900 AC CC3000 controller Temperature sensor Cable 8 wire w Anytec terminal...

Страница 22: ...3000 rear 4 x 3mm Break away to integrate cable trays Access connectors Fasten main part to the wall mount Press to release Remove front cover to access connectors Use two screws to secure the main pa...

Страница 23: ...en the SD card is inserted the controller will automatically update firmware See instructions in display Until the SD card is inserted the controller will remain inactive and the buttons will not func...

Страница 24: ...ed Test steps can be bypassed by pressing down key A manual sequence can also be used if only certain outputs are checked Use up down key to select output and press enter Output is now activated Press...

Страница 25: ...25 Controller CC3000 Connections diagram...

Страница 26: ...ottom of P band 25 Max C Temperature at top of P band 29 SetPoint The wanted indoor temperature fan speed will be adjusted between Min C and Max C 27 Emergency on Fan run 100 38 Emergency off Fan go b...

Страница 27: ...31 A C 1 off External Air Con unit 1 stops if connected 29 A C 2 on External Air Con unit 2 start if connected 33 A C 2 off External Air Con unit 2 stops if connected 31 Emergency on Fan run 100 and...

Страница 28: ...ed 31 A C 1 off External Air Con unit 1 stops if connected 29 A C 2 on External Air Con unit 2 start if connected 33 A C 2 off External Air Con unit 2 stops if connected 31 Emergency on Fan run 100 an...

Страница 29: ...unit 1 stops if connected 25 A C 2 on External Air Con unit 2 start if connected 29 A C 2 off External Air Con unit 2 stops if connected 27 Emergency on Fan run 100 and both A C 1 and A C 2 starts 38...

Страница 30: ...717 Common for FB 900 DC and FB 900 AC CC3000 control including SD card configured for all units 093719 CC 3000 Connector Kit 092081 Controller Cable for CC3000 093724 Filter Guard monitor 840020 Outd...

Страница 31: ...hines 2014 35 EU Low Voltage Directive 2014 30 EU EMC Directive 2011 65 EU RoHS Directive and is manufactured in conformity with the following harmonised standards EN 12100 2011 Safety of Machinery EN...

Страница 32: ...m Dantherm Limited 12 Windmill Business Park Windmill Road Clevedon North Somerset BS21 6SR England Phone 44 0 1275 87 68 51 Fax 44 0 1275 34 30 86 infouk dantherm com www dantherm co uk Dantherm Cool...