The ACT-7 is a portable air conditioner intended for small-scale temporary cooling, and can 

be used in many different places such as rental companies, event organization, workshops 

and offices.

Description

Illustration

The ACT-7 comprises 

• 

a room unit and 

• 

external heat exchanger.

The interconnecting line (max 

30 m) which connects the two 

parts together includes two 

water pipes, condensed waste 

water pipe and an electrical 

supply power cord. Both ends 

of the water pipes are fitted 

with ‘quick connect’ couplings 

that open on connection but 

reseal to become water tight 

on disconnection.

  

    

4

3

2

1

5

6

8

7

9

10

11

12

13

 Front 

Rear

Fig. 2 

Pos . Description

Pos . Description

1

Mode switch

8

Water pipe coupling (IN)

2

Fan speed control dial

9

Electrical supply connection

3

Grille

10

Tank filler

4

Display

11

Inspection window

5

Handle for moving the unit

12

Condensed waste water outlet

6

Wheels

13

Cable keeper

7

Water pipe coupling (OUT)

Designated use

ACT-7 system 

connection

Fig. 1 

Illustration  

(Room unit)

en

Содержание ACT-7 EU

Страница 1: ...ACT 7 USER MANUAL en Rev 1 1 2019 W14 5...

Страница 2: ...ight to make changes and improvements to the product and the service manual at any time without prior notice or obligation This unit is designed for long term durability When total lifetime ends the u...

Страница 3: ...es two water pipes condensed waste water pipe and an electrical supply power cord Both ends of the water pipes are tted with quick connect couplings that open on connection but reseal to become water...

Страница 4: ...se A 16 13 Nominal current A 11 2 11 Power consumption nominal kW 2 6 2 5 Airflow internal stepless variable m3 h 930 1310 Sound level 3 metres indoor max speed dBA 56 Operating range room temperature...

Страница 5: ...tioned side by side and equally spaced along the long wall all pointing in the same direction x x x Around the perimeter Sometimes it may be necessary to position units around the pe rimeter of an ar...

Страница 6: ...nal heat ex changer and find a location where debris can t get into the air flow of the heat exhanger a The heat exchanger can stand freely on a at surface or b It may be hung in the upright position...

Страница 7: ...n irritation The substance can be difficult to remove from clothes Use gloves for connecting and disconnecting the interconnecting line If the glycol water mixture is spilled on your skin wash thoroug...

Страница 8: ...to 20 C This speci cation will protect the entire glycol water circuit down to 16 C 5 F 5 Mount the cap and security plate again Step Description Illustration 1 Use the interconnecting line 5 30m to c...

Страница 9: ...electrical supply in the section Electrical sup ply on page 9 Plug the room unit into a power socket As standard the ACT 7 requires a fused electrical supply UK 13A Europe 16A rated at 230 Volts 1N 50...

Страница 10: ...a mains power to room unit and b power cord between heat exchanger and room unit a b 3 Disconnect drain hose from the heat exchanger a Use a screwdriver to remove the blue collet from the hose connect...

Страница 11: ...ith grilles that allow the angle of air outlet to be adjusted In conjunction with the fan speed control switch the air velocity and direction can be carefully set up to obtain maximum coverage of the...

Страница 12: ...six minute delay timer when switching to A C mode from stand by or fan only modes Cooling will start after this delay period 3 Navigation buttons Return OK Save Enter menu submenu Press for 2 seconds...

Страница 13: ...ooting on page 16 5 Tank full indicator flashing The alarm resets itself and works as follows 1 When the alarm appears the ACT 7 will continue to work for the next 30 seconds 2 If the condensate tank...

Страница 14: ...fault See trouble shooting on page 16 LP fault See trouble shooting on page 16 Advanced Access the submenus Offset An offset 0 99 is used to calibrate the temperature shown on the main screen This fe...

Страница 15: ...and clean as needed Follow this procedure to perform the monthly service Step Action Inspect clean air filter 1 Remove the upper front plate by pushing it up and pulling it out 2 The filter is fitted...

Страница 16: ...r glycol mixture See instruction on page 7 External heat exchanger has blocked air ways Clean the fan and the coil with a vacuum cleaner or water and a brush see instruction on page 15 kinked hoses Ch...

Страница 17: ......

Страница 18: ......

Страница 19: ......

Страница 20: ...support dantherm com Dantherm can accept no responsibility for possible errors and changes en Der tages forbehold for trykfejl og ndringer da Irrt mer und nderungen vorbehalten de Dantherm n assume au...

Отзывы: