Dantherm Cooling HexFlow HF17115 Скачать руководство пользователя страница 3

HEXFLOW PRODUCT USER MANUAL

3

UNPACKING 

|

 SAFETY

UNPACKING, HANDLING, AND 

INSPECTION

Thank you for purchasing a Dantherm HexFlow 

heat exchanger.  Please carefully review all 

handling and installation instructions.

• The heat exchanger should be inspected on 

initial delivery and any damage to packaging 

noted. 

• The unit should be maintained in the upright 

position at all times.

• Special consideration should be given to

correctness of external packing damage or 

abrasion, loose components and surface marks. 

• Any damage should be added to the freight 

bill and immediately notify the freight company 

for filing a freight

claim. 

• All packaging materials should be retained for 

inspection.

Do not attempt to operate the unit if it appears 

to be damaged.

GENERAL SAFETY

• Certain parts of electrical systems are 

inevitably live or have high operating 

temperatures. Observe caution at all times.

• Failure to observe these conditions and 

installation instructions can cause injury and 

damage.

• The system is to be installed and maintained 

only by trained and qualified personnel.

• Do not apply power until all ground 

connections have been made.

• The unit is fitted with pressed and folded 

metal parts, which could have sheared metal 

edges. Be cautious handling the unit, especially 

when working in poorly accessible places.

• Check that no tools, test equipment, torches 

etc. have been left in or on the equipment on

completion of work.

• Ensure the cover(s) and all mounting hardware 

is firmly secured before leaving installation.

• All cable and connectors must conform to UL 

standards.

• The heat exchanger is UL recognized 

and tested to UL1995. It will comply where 

necessary with the safety requirements as 

defined in UL1995.

Содержание HexFlow HF17115

Страница 1: ...DANTHERMCOOLING COM TECHSUPPORT DANTHERMCOOLING COM 864 595 9800 671 SPRINGFIELD ROAD SPARTANBURG SOUTH CAROLINA 29303 HexFlow Product User Manual...

Страница 2: ...IGHT Copying of this service manual or part of it is forbidden without prior written permission from Dantherm Cooling Inc RESERVATIONS Dantherm reserves the right to make changes and improvements to t...

Страница 3: ...AL SAFETY Certain parts of electrical systems are inevitably live or have high operating temperatures Observe caution at all times Failure to observe these conditions and installation instructions can...

Страница 4: ...t Type 0XX Designated Nominal Height Example Model Number P S 035 045 230 TI OPTIONS Speed Control S The controller is designed to slow down the speed of the internal and external fans at lower temper...

Страница 5: ...DESCRIPTION 1 Cabinet Air IN 2 Cabinet Air Out 3 Ambient Air IN 4 Ambient Air Out 5 Mounting Hook 6 Installation Gasket 1 2 6 VIEW 2 PART DESCRIPTION 1 Cabinet Air IN 2 Cabinet Air OUT 3 Installation...

Страница 6: ...e lifting device Connect the Heat Exchanger power lead to the mains supply located in the cabinet enclosure Refer to the product label on the bottom right hand side panel of the unit for the proper vo...

Страница 7: ...HEXFLOW PRODUCT USER MANUAL 7 CUT OUT AND MOUNTING DIAGRAMS CUT OUT AND MOUNTING DIAGRAMS HF17 22 Mid Mount Models HF17 22 Models...

Страница 8: ...HEXFLOW PRODUCT USER MANUAL 8 CUT OUT AND MOUNTING DIAGRAMS HF26 HF35 45 55 Models...

Страница 9: ...HEXFLOW PRODUCT USER MANUAL 9 CUT OUT AND MOUNTING DIAGRAMS HF100...

Страница 10: ...0 60 1 3 4 6 59 27 HF35230 35 230 VAC 50 60 1 0 86 2 5 59 27 HF3548 35 48 VDC N A N A 4 3 6 59 27 HF45115 45 115 VAC 50 60 1 3 4 5 64 29 HF45230 45 230 VAC 50 60 1 1 86 2 5 64 29 HF4548 45 48 VDC N A...

Страница 11: ...WIRING DIAGRAMS The following schematics are of standard products only Wiring schematics for options or custom products are available directly from Dantherm Cooling AC Voltage Diagram All Models DC Vo...

Страница 12: ...HEXFLOW PRODUCT USER MANUAL 12 WIRING DIAGRAMS DC Voltage Diagram with HX2 Speed Control up to batch 130601 DC Voltage Diagram with HX2 Speed Control batch 130601 and newer...

Страница 13: ...lack of normal preventive maintenance or other events beyond DANTHERM s control This warranty is also subject to the following operating conditions 1 voltage variation not greater than 10 2 frequency...

Страница 14: ...unit failure the following return procedure shall be adopted All product returns require a Return Material Authorization number regardless of reason The customer is required to contact the Quality De...

Страница 15: ...DANTHERMCOOLING COM TECHSUPPORT DANTHERMCOOLING COM 864 595 9800 671 SPRINGFIELD ROAD SPARTANBURG SOUTH CAROLINA 29303...

Отзывы: