05725-02-0499 <90-00201>

 P

AGE

 25

INSTALLATION

SWITCH

BRDG

LPBK 1

(S2)

LPBK 2

(S101)

SWITCH

TERM

RPTR *

OFF *

ON

OFF *

ON

SWITCH

Channels 1 and 2 operate independently.

Channels 1 and 2 are bridged together.

Analog signals for Channel 1 are not looped back.
Analog signals from the transmit input of Channel 1 are looped back

to the receive output of Channel 1. Use to check or set audio levels.

Analog signals for Channel 2 are not looped back.
Analog signals from the transmit input of Channel 2 are looped back

to the receive output of Channel 2. Use to check or set audio levels.

STRAP

XMT CLK 1

(see note below)

RCV CLK 1

RCV DATA 1

XMT CLK 2

(see note below)

RCV CLK 2

RCV DATA 2

E LEAD 1

E LEAD 2

M LEAD 1

M LEAD 2

MODE

(S1)

POSITION

TERM *

TTL+

TTL–

TERM *

TTL+

TTL–

TERM *

TTL+

TERM *

TTL+

TTL–

TERM *

TTL+

TTL–

TERM *

TTL+

NO *

NC

NO *

NC

YES

NO *

YES

NO *

TERM

RPTR *

DESCRIPTION

180-ohm termination across RS-422 inputs at pins 51 and 52

XMT CLK 1 pin 51 is TTL (+ edge) compatible; pin 52 is not used

XMT CLK 1 pin 52 is TTL (– edge) compatible; pin 51 is not used
180-ohm termination across RS-422 inputs at pins 45 and 46

RCV CLK 1 pin 45 is TTL (+ edge) compatible; pin 46 is not used

RCV CLK 1 pin 46 is TTL (– edge) compatible; pin 45 is not used
180-ohm termination across RS-422 inputs at pins 43 and 44

RCV DATA 1 pin 43 is TTL compatible; pin 44 is not used

180-ohm termination across RS-422 inputs at pins 5 and 6
XMT CLK 2 pin 5 is TTL (+ edge) compatible; pin 6 is not used

XMT CLK 2 pin 6 is TTL (– edge) compatible; pin 5 is not used

180-ohm termination across RS-422 inputs at pins 11 and 12
RCV CLK 2 pin 11 is TTL (+ edge) compatible; pin 12 is not used

RCV CLK 2 pin 12 is TTL (– edge) compatible; pin 11 is not used

180-ohm termination across RS-422 inputs at pins 13 and 14
RCV DATA 2 pin 13 is TTL compatible; pin 14 is not used

Relay at pins 39 and 40 is normally open when E Lead 1 is active

Relay at pins 39 and 40 is normally closed when E Lead 1 is inactive
Relay at pins 19 and 20 is normally open when E Lead 2 is active

Relay at pins 19 and 20 is normally closed when E Lead 2 is inactive

M Lead 1 input at pins 41 and 42 is used
M Lead 1 input at pins 41 and 42 is not used

M Lead 2 input at pins 15 and 16 is used

M Lead 2 input at pins 15 and 16 is not used
Digital sections of channel 1 and 2 are not interconnected.

Select this position when the channels will operate independently.

BRDG switch also must be in the TERM position.
Digital sections of channel 1 and 2 are interconnected, bypassing the

analog sections when they are not in use. Select this position when the

channels are bridged together in the repeater mode.
BRDG switch also must be in the RPTR position.

N

OTE

:

If an external clock is not used, strap XMT CLK 1 and XMT CLK 2 to TTL+.

T

ABLE

 L - 46105 S

WITCH

 

AND

 S

TRAP

 O

PTIONS

Содержание B15-00459-02

Страница 1: ...a banner in the right margin UPDATED Table of Contents Ordering Information 2 General Description 2 Installation 5 Turn Up Procedure 29 Support Documentation 41 Warranty 42 xmt out loop mon 4003C line...

Страница 2: ...drawing that accompanies this Application Manual The 02 option is equipped with a 46105 Dual VF 64 kilobit Chan nel Module The output of this shelf is a digital signal that can be transmitted over a...

Страница 3: ...ster Port is used to report the alarm information to the alarm center through the E System Adapter The Master Port provides mounting for the RS 232 subassem bly E System Adapter ESA slot 8 The ESA pro...

Страница 4: ...A B C D 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 A B C D A1 A2 RST ACK A1 ON XMT DATA RCV DATA 46009 0X 32 POINT TRANSMITTER 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 A B C D 1 2 3 4 5 6 7 8 9 10 11 12 13...

Страница 5: ...labs 4003C 46105 Dual VF 64 kilobit Channel 46019 Summary Alarm Module 48001 Fuse Module 4 Summary of Switch Settings EQUIPMENT MOUNTING Tools Required Ohmmeter Phillips screwdriver 7 16 Nutdriver or...

Страница 6: ...1 25 1 16 TB 1 16 TB 15 30 15 30 C1 C2 C3 C4 TB 1 2 3 4 5 6 7 8 9 10 A B E F C5 C6 C7 C8 C1 C2 C3 C4 PANEL D PANEL C PANEL B PANEL A DC GND 1 1 1 1 1 25 50 26 XMIT REC LINE ZAET Circuit LIST 13 CABLS...

Страница 7: ...frame rail 4 Place ESD label next to the ESD stud 5 From the rear of the bay install the other ESD stud and lockwasher into the frame rail next to the equipment shelf Secure tightly ensur ing proper...

Страница 8: ...C 2D 3A 3B 3C 3D CPM TB A 5B 5D 5A 5C 29 30 MAT MAT WIRING ADDED WHEN PANEL IS NOT EQUIPPED WITH A MAC CARD 1 2 3 4 5 6 7 8 9 1 0 A B C D E F TB A T E R M I N A L S T R I P B A C K P L A N E I N P A N...

Страница 9: ...46009 Multiple Alarm Transmitter MAT Refer to Fig 5 and Table A FIG 5 46009 MAT SWITCH AND STRAP LOCATIONS INSTALLATION 1 2 3 4 1 2 3 4 5 6 7 8 1 2 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 BOTTOM EDGE S5 S4 S...

Страница 10: ...that the switch is down down ON DCM addresses 17 18 display 5 bits 1 32 DCM addresses 19 20 display 5 bits 33 63 NOTE The MATs in slots 1 and 2 are not interchangeable without changing the address on...

Страница 11: ...3 4 5 6 7 8 1 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 Leave in NORM Leave in A position 46020 38 Multiple Alarm Processor MAP Refer to Figs 7 and 8 and Tables C and D FIG 7 46020 MAP SUBASSEMBLY AND SWITCH LOCA...

Страница 12: ...n remove power and place switch 5 position 7 DOWN This will retain the configuration in memory TABLE C SWITCHES 1 THRU 4 46020 38 SWITCH SW5 SW6 SW7 POSITION 1 2 3 4 5 6 7 8 1 1 1 1 1 1 0 1 1 1 1 1 1...

Страница 13: ...Normal Position TXD RXD RTS and DCD reversed CTSusedforhandshaking CTS not used for handshaking DCDusedforhandshaking DCD not used for handshaking ParallelOption YES NO SWITCH OR STRAP SETTINGS S1 00...

Страница 14: ...Table F 1 0 1 0 0 0 0 0 0 1 1 1 1 1 1 1 NOTE A 1 indicates that the rocker switch is up adjacent to the position number open OFF A 0 indicates that the rocker switch is down adjacent to the position...

Страница 15: ...1 0 0 0 0 0 0 0 1 0 0 1 0 0 0 0 1 0 1 0 0 0 0 0 1 0 1 1 0 0 0 0 1 1 0 0 0 0 0 0 1 1 0 1 0 0 0 0 1 1 1 0 0 0 0 0 1 1 1 1 0 0 0 1 0 0 0 0 0 0 0 1 0 0 0 1 0 0 0 1 0 0 1 0 0 0 0 1 0 0 1 1 0 0 0 1 0 1 0 0...

Страница 16: ...0 0 1 0 0 1 0 0 0 1 0 0 0 1 0 0 0 1 1 0 0 1 0 0 1 0 0 0 0 1 0 0 1 0 1 0 0 1 0 0 1 1 0 0 0 1 0 0 1 1 1 0 0 1 0 1 0 0 0 0 0 1 0 1 0 0 1 0 0 1 0 1 0 1 0 0 0 1 0 1 0 1 1 0 0 1 0 1 1 0 0 0 0 1 0 1 1 0 1 0...

Страница 17: ...0 1 1 0 1 0 1 1 1 0 0 0 1 0 1 1 1 0 1 0 1 0 1 1 1 1 0 0 1 0 1 1 1 1 1 0 1 1 0 0 0 0 0 0 1 1 0 0 0 0 1 0 1 1 0 0 0 1 0 0 1 1 0 0 0 1 1 0 1 1 0 0 1 0 0 0 1 1 0 0 1 0 1 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 1 0...

Страница 18: ...0 1 0 0 0 0 1 1 1 1 0 0 0 1 0 0 0 1 0 0 0 1 0 0 1 1 0 0 0 1 0 1 0 1 0 0 0 1 0 1 1 1 0 0 0 1 1 0 0 1 0 0 0 1 1 0 1 1 0 0 0 1 1 1 0 1 0 0 0 1 1 1 1 1 0 0 1 0 0 0 0 1 0 0 1 0 0 0 1 1 0 0 1 0 0 1 0 1 0 0...

Страница 19: ...0 1 0 1 1 0 0 1 1 1 0 1 1 0 1 0 0 1 0 1 1 0 1 0 1 1 0 1 1 0 1 1 0 1 0 1 1 0 1 1 1 1 0 1 1 1 0 0 0 1 0 1 1 1 0 0 1 1 0 1 1 1 0 1 0 1 0 1 1 1 0 1 1 1 0 1 1 1 1 0 0 1 0 1 1 1 1 0 1 1 0 1 1 1 1 1 0 1 0 1...

Страница 20: ...0 1 1 1 1 1 1 1 1 0 0 0 0 0 1 1 1 0 0 0 0 1 1 1 1 0 0 0 1 0 1 1 1 0 0 0 1 1 1 1 1 0 0 1 0 0 1 1 1 0 0 1 0 1 1 1 1 0 0 1 1 0 1 1 1 0 0 1 1 1 1 1 1 0 1 0 0 0 1 1 1 0 1 0 0 1 1 1 1 0 1 0 1 0 1 1 1 0 1 0...

Страница 21: ...e only TABLE G CONTINUED 46033 E SYSTEM ADAPTER S2 SWITCH SETTINGS 49013 202 Tone Modem Subassembly Refer to Fig 11 and Table H for switch and strap settings FIG 11 49013 202 TONE MODEM SWITCH AND STR...

Страница 22: ...ON S2 OFF 1 2 1 2 3 4 OFF 5 Transmit and Receive channel level switches are located on front panel Note that the settings shown are factory settings Change per Engineer s instructions IN IN 1 2 4 8 1...

Страница 23: ...FF 1 ON refer to Table J OFF ON FRONT PANEL LEVEL SWITCHES XMT 0 dB refer to Fig 12 RCV 0 dB refer to Fig 12 TABLE I 4003C SWITCH OPTIONS TABLE J 4003C LOOPBACK FREQUENCY SELECTION S13 FREQUENCY 2813H...

Страница 24: ...L TM T T TM T T TERM RPTR S101 S2 S1 T T L T E R M RCV DATA T T L T T L T E R M RCV CLK T T L T T L T E R M XMT CLK Y E S N O M LEAD N C N D E LEAD 46105 Dual VF 64 Kilobit Channel Refer to Fig 13 and...

Страница 25: ...is TTL compatible pin 44 is not used 180 ohm termination across RS 422 inputs at pins 5 and 6 XMT CLK 2 pin 5 is TTL edge compatible pin 6 is not used XMT CLK 2 pin 6 is TTL edge compatible pin 5 is...

Страница 26: ...to scale SWITCH 1 2 3 4 POSITION ON Timeout 0 5 min ON Timeout 1 0 min ON Timeout 4 0 min ON Timeout 8 0 min Setting for this application All switches OFF no timeout Only one switch may be on at a ti...

Страница 27: ...01 01 REV __ Alarm 1 2 3 4 5 6 7 8 9 10 11 12 JP1 1 2 3 POSITION Pins 1 2 Pins 2 3 DESCRIPTION RedundantorSingleInput TwoIndependantInputs Setting for this application 48001 Fuse Module Refer to Fig 1...

Страница 28: ...inter syntax 9600 baud master port set for DCP protocol address 1 E system mode on 1200 baud data port set for 9600 baud DCM protocol no TBOS S1 set for 00 normal mode CTS not used X1 on DCD not used...

Страница 29: ...0062 00 DB 15 M M cables between C1 and C2 and the fiber optic terminals 4 Mount the A25 00710 00 frame block on a frame or use the A25 00508 01 23 Block mounting bar to mount the cross connect block...

Страница 30: ...k These levels need not be changed unless they are not within the 1 dB tolerance but they should be verified on the routine level maintenance schedule FIG 16 TONE LEVELS CONTINUED Dantel TELLABS 4003C...

Страница 31: ...be required to verify suspected bad modules or to set levels on modules that have been swapped out SLOTS 1 AND 2 MULTIPLE ALARM TRANSMITTER MAT NOTE Slots 3 and 4 are wired only and not equipped The...

Страница 32: ...Z D 4 TELLABS 4003C 46020 40 XMT DATA 49029 00 RS232 XMT DATA RCV DATA RTS DCD DTR CTS Not Used LEDs will be on 46105 XX DUAL VF 64B CHAN XMT 46105 XX RCV SYNC RCV LVL GND XMT RCV SYNC RCV LVL GND Syn...

Страница 33: ...to 64 and observe the MAT alarm LEDs The corresponding LED on the MAT should light up whenever the alarm input of the A25 00710 00 block is grounded MAT 1 is for alarm inputs 1 to 32 and MAT 2 is for...

Страница 34: ...o the CPM and that all of the points are now released This will turn off all control points 5 Observe the CPM LEDs from 1 through 16 they should now be off 6 Use the ohmmeter again and check all contr...

Страница 35: ...ace the MAP with a 49029 subassem bly on it with a known good one that has the switches set cor rectly per the Tables Changing Default Alarm Levels All alarms default to a D level If it is necessary t...

Страница 36: ...To see if the devices are correctly loaded type MAT MAT address SHOW Or in this case MAT 5 SHOW The MAT level assignment will come back as follows MAT 5 OPTIONS A A A A A A A A A A A A A A A A NOTE A...

Страница 37: ...een changed during shipment NOTE The following steps should be only be used to verify the level settings They should only be required if modules are swapped or to test suspected bad modules 1 Using a...

Страница 38: ...e used to only verify the level settings They should only be required if modules are swapped out or to test suspected bad modules 1 Refer to Fig 4 and set the bridge terminal switch to terminal Set th...

Страница 39: ...ated 1 kHz signal into the DROP XMT jack for channel 2 on the front panel of the 46105 module 16 Verify with the dB meter not terminated a level of 0 dB at both XMT LVL test point jacks for channel 1...

Страница 40: ...5 Replace the blown fuse with a good one the short should be removed and the LED should be off GENERALTROUBLESHOOTING If difficulties are experienced with this unit check the following as appropriate...

Страница 41: ...DANTEL Included in this section 46020 38 Installation and Operation Manual B18 05725 XX Block and Level Drawing DJ 05725 Ordering Guide an RMA number Include a description of the malfunction with the...

Страница 42: ...en instrument signed by a duly authorized officer of the Seller and accepted by the Buyer Warranty and remedies on products not manufactured by the Seller are in accordance with warranty of the respec...

Отзывы: