![Dantel B15-00459-02 Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/dantel/b15-00459-02/b15-00459-02_installation-and-operation-manual_3487156013.webp)
05725-02-0499 <90-00201>
P
AGE
13
INSTALLATION
49029 RS-232 Current Loop Interface Subassembly
Refer to Fig. 9 and Table E.
F
IG
. 9 - 49029 S
WITCH
AND
S
TRAP
P
OSITIONS
X2
X1
X3
1 2 3
P4
-00
-01
S1
ON
CTS
THRU
DCD
P5
T
ABLE
E - 49029 S
WITCH
AND
S
TRAP
S
ETTINGS
OPTION
Normal Position *
TXD, RXD, RTS, and DCD reversed
CTS used for handshaking
CTS not used for handshaking *
DCD used for handshaking
DCD not used for handshaking *
Parallel Option
YES
NO *
SWITCH OR STRAP SETTINGS
S1 - -00 Mode
S1 - -01 Mode
X1 - THRU
X1 - ON
X2 - THRU
X2 - ON
X3 - Jumper pins 2 & 3
X3 - Jumper pins 1 & 2
N
OTE
:
Default switch and strap positions
are indicated by a
*
. For more
detail and further explanations
about the individual modules, re-
fer to the practices specific to that
module.