background image

48001-1097 <90-00033>

 P

AGE

 11

NOTES

Содержание B11-48001-01

Страница 1: ...ctrostatic discharge safety precautions refer to BellcoreTM Technical Reference TR NWT 000870 Copyright 1997 by Dantel Inc Dantel is a registered trademark of Dantel Inc ISO 9001 Registered Printed in...

Страница 2: ...The module fits into any 400 type or similar equipment housing and operates on 21 to 56 VDC input power The front panel includes 13 indicating type GMT fuses and an alarm LED CIRCUIT DESCRIPTION The...

Страница 3: ...F13 F1 THRU F6 3 1 9 13 21 25 29 39 47 51 55 5 43 35 FUSED OUTPUTS TO CIRCUITS FUSED OUTPUTS TO CIRCUITS BATT INPUT EXTERNAL ALARM INPUTS GND 52 2 12 4 8 6 10 TO ALARM SYSTEM AS REQUIRED Kl Kl 32 31...

Страница 4: ...red by each fuse group draws less than 5 amps only one pin of each group is needed Refer to Fig 1 Use both inputs to each group if The current draw for each group exceeds 5 amps A single input is used...

Страница 5: ...To install the B11 48001 01 Fuse Module place it in the proper slot in the equipment shelf However several factors deserve attention before installation JP1 AND BATTERY INPUTS Refer to Fig 2 The modul...

Страница 6: ...rough 6 Connect a second power supply to pins 31 and or 32 This provides power to fuse group 2 fuses 7 through 13 EDGE CONNECTOR PINS Normally the 56 pin edge connector for the slot is prewired at the...

Страница 7: ...C BOARD Fused Circuit 1 External Alarm Input Fused Circuit 2 External Alarm Input Fused Circuit 3 Fused Circuit 4 Fused Circuit 5 Battery Group 1 Battery Group 1 Battery Group 2 Battery Group 2 Fused...

Страница 8: ...ellow rivits to indicate 0 18 amp fuses 10 violet rivits to indicate 0 25 amp fuses Fuse ratings and their associated color codes along with part numbers for fuses and rivits supplied by Dantel are li...

Страница 9: ...vit with a small flat object The rivit when loosened falls out the front side of the hole in the face plate Fit the new color coded rivit into the vacant opening from the front of the front panel Whil...

Страница 10: ...VDC Non Alarmed Alarmed 56 VDC Non Alarmed Alarmed Heat Dissipation 21 VDC Non Alarmed Alarmed 56 VDC Non Alarmed Alarmed Fuse Ratings Weight Physical Dimensions Operating Temperature Range VALUE 21 t...

Страница 11: ...48001 1097 90 00033 PAGE 11 NOTES...

Страница 12: ...n instrument signed by a duly authorized officer of the Seller and accepted by the Buyer Warranty and remedies on products not manufactured by the Seller are in accordance with warranty of the respect...